• 제목/요약/키워드: constant current source

검색결과 252건 처리시간 0.03초

12-펼스 위상제어 정류기를 사용한 전류원 (A Current Source using the 12-Pulse Phase-Controlled Rectifier)

  • 송의호;권봉환
    • 대한전기학회논문지
    • /
    • 제39권6호
    • /
    • pp.545-556
    • /
    • 1990
  • A design method of a current source using 12-pulse phase-controlled rectifier (PCR) is presented. The critical inductance of the 12-pulse PCR is derived and it is shown that the critical inductance can be reduced using a current source. The control circuit of the 12-pulse PCR with an inner fast dynamic loop is proposed to give the frequency synchronism and to reduce the subharmonics due to the unbalance of the transformer of the power line. This circuit is analyzed and its dynamic loop is optimized. The optimal constant PIMF (proportional, integral and measurable variable feedback, and feedforware) controller is also designed using the time-weighted quadratic performance index. It is shown via experimental results that the proposed design method gives high dynamic and static performance of the current source using the 12-pulse PCR.

Automatic frequency Control Current-Source Inverter for Forging Application

  • Chudjuarjeen, Saichol;Koompai, Chayant;Monyakul, Veerapol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.238-242
    • /
    • 2004
  • The paper describes an automatic frequency control current-fed inverter for forging applications. The IGBT in series with diodes as its switching devices in the inverter circuit which is of full-bridge type. The operating frequency is automatically tracked to maintain a small constant leading phase angle when load parameters change. The load voltage is controlled to protect the switches. The output power can be adjusted by varying the input current from phase controlled rectifiers which is a part of current source. The system has been operated at 15-17 kHz. The output power transferred to the load is 1,595 watts. It can heat the steel work pieces with 15 mm diameter and 120 mm long from room temperature to approximately 1100 $^{\circ}C$ within 20 seconds with 0.97 leading power factor on the input side.

  • PDF

PV효과를 이용한 전압형 인버어터 전원동기 전압 조정기에 관한 연구 (A Study on Synchronized AC Power Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic effect)

  • 황락훈
    • 전자공학회논문지S
    • /
    • 제35S권8호
    • /
    • pp.120-129
    • /
    • 1998
  • 본 논문은 PWM(Pulse width Modulation)전압형 인버어터를 사용하여 전원차단 경우나 전압변동 및 부하변동에 의한 출력전류 변화에도 일정한 출력전압을 유지하는 무정전 전원장치에 대해 논하였다. 본 시스템은 전압형 인버어터를 교류전원과 동기시켜 운전하고 정상상태에서는 전원으로부터 운전하고 정상상태에서는 전원으로부터 직류측에 연결된 축전지를 태양전지를 이용한 광기전력효과와 함께 일정전압을 충전하며, 전원의 차단, 전원의 전압변동 및 부하전류의 변화에도 일정한 전압을 유지하도록 하였다. 출력은 PWM방식에 의하여 양호한 파형이 되도록 하고 전원차단과 부하의 상태의 변화 및 전원 전압 변동에도 일정한 전압으로 출력됨을 실험을 통하여 확인할 수 있었다.

  • PDF

Accuracy of Current Delivery System in Current Source Data-Driver IC for AM-OLED

  • Hattori, Reiji
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권4호
    • /
    • pp.269-274
    • /
    • 2004
  • Current delivery system, in which the analog current produced by a unique DAC circuit is stored into a current-memory circuit and delivered in a time-divided sequence, shows variation of output current as low as 4% in a current source data-driver IC for AM-OLED driven by a current-programmed method without any fuse repairing after fabrication. This driver IC has 54 outputs and can sink constant current as low as 3 ${\mu}A$ with 6-bit analog levels. Such a low current level without variation can hardly be obtained by an ordinary MOS transistor because the current level is in the sub-threshold region and changes exponentially with threshold voltage variation. Thus we adopted a current mirror circuit composed of bipolar transistors to supply well-controlled current within a nano-ampere range.

전압을 구동함수로 한 선형 유도전동기의 유한요소 해석 (Finite Element Analysis of L.I.M. Considering the Voltage as a Driving Source)

  • 임달호;최창규
    • 대한전기학회논문지
    • /
    • 제40권3호
    • /
    • pp.250-257
    • /
    • 1991
  • In the analysis of the electric machine by finite element method, the primary current has been selected as a driving source. But the voltage is constant and the primary current varies according to the load condition in the pracdtical system. Therefore, in this paper, magnetic flux distribution, primary current, input effective power, power factor, efficiency and propulsion force of S.L.I.M. were calculated by the finite element method cnsidering the voltage as a driving source. Because the driving characteristics could not be measured in the S.L.I.M., voltage-current curve, 3-phase current curve, and propulsion force were measured at the starting and they were compared with theoretical values.

Current Source ZCS PFM DC-DC Converter for Magnetron Power Supply

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.20-28
    • /
    • 2009
  • This paper presents the design of zero current switching ZCS pulse frequency modulation type DC-DC converter for magnetron power supply. A magnetron serving as the microwave source in a microwave oven is driven by a switch mode power supply (SMPS). SMPSs have the advantages of improved efficiency, reduced size and weight, regulation and the ability to operate directly from the converter DC bus. The demands of the load system and the design of the power supply required to produce constant power at 4[kV]. A magnetron power supply requires the ability to limit the load current under short circuit conditions. The current source series resonant converter is a circuit configuration which can achieve this. The main features of the proposed converter are an inherent protection against a short circuit at the output, a high voltage gain and zero current switching over a large range of output power. These characteristics make it a viable choice for the implementation of a high voltage magnetron power supply.

제너다이오드의 열화평가를 위한 전압제어 출력 전류원 개발 (Development of a voltage-controlled output current source for zenor diode degradation analysis)

  • 김종호;장홍기;권영목;최규식
    • 한국항행학회논문지
    • /
    • 제21권5호
    • /
    • pp.501-507
    • /
    • 2017
  • 전자회로에서 부하가 제너다이오드일 경우, 입력전압에 의해 부하의 전류를 제어하고자 할 때 제너다이오드의 항복전압 특성에 따라 제어하고자 하는 출력전류가 변하기 때문에 기존의 전압제어 전류 생성 방법을 적용할 수 없다. 이 논문에서는 입력전압을 이용하여 정격치보다 큰 전류를 제너다이오드에 인가하여 부품의 수명시험을 할 때, 제너다이오드가 경년열화에 의하여 항복전압의 특성이 변하여 부하전압이 달라져도 이에 관계없이 동일한 전류를 낼 수 있는 회로를 개발하였다. 이 방법으로 구성된 회로를 실증하기 위해 각 블럭의 부품 값을 적용하고 시뮬레이션 하여 입력전압으로 출력전류를 선형적으로 제어하는 결과를 확인하였다. 결과에 의하면 우리가 측정하고자 하는 항복전압 이상의 입력전압에 대해서 출력전류가 선형적으로 변하며 제너다이오드의 경년열화에 의한 항복전압의 변화와 관계없이 일정한 전류가 흐르는 것을 확인하였다.

A New Approach for Constant DC Link Voltage in a Direct Drive Variable Speed Wind Energy Conversion System

  • Jeevajothi, R.;Devaraj, D.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.529-538
    • /
    • 2015
  • Due to the high efficiency and compact mechanical structure, direct drive variable speed generators are used for power conversion in wind turbines. The wind energy conversion system (WECS) considered in this paper consists of a permanent magnet synchronous generator (PMSG), uncontrolled rectifier, dc-dc boost converter controlled with maximum power point tracking (MPPT) and adaptive hysteresis controlled voltage source inverter (VSI). For high utilization of the converter's power capability and stabilizing voltage and power flow, constant DC-link voltage is essential. Step and search MPPT algorithm which senses the rectified voltage ($V_{DC}$) alone and controls the same is used to effectively maximize the output power. The adaptive hysteresis band current control is characterized by fast dynamic response and constant switching frequency. With MPPT and adaptive hysteresis band current control in VSI, the DC link voltage is maintained constant under variable wind speeds and transient grid currents respectively.

주파수 변화에 의한 유도전동기의 특성 (Characteristics of induction motor by changing the frequency of source)

  • 박민호
    • 전기의세계
    • /
    • 제14권5호
    • /
    • pp.20-27
    • /
    • 1965
  • There are several methods of speed control in induction motors. One of which is to change the frequency of source but was not used frequently because of the difficulty of frequency-change. Then, the development of frequency changer using semiconductor enables the method useful. In this paper the speed characteristics of mechanical output, secondary input torque and secondary power factor are described when the frequency of source and voltage which is proportional to the frequency of source in order to make the flux in the air gap in constant, are changed. The above characteristics are searched on the basis of the rated characteristics of the motor. Because the ratio of these is proportional to that of the secondary current or the square value of it. To get the ratio of the secondary current, a current circle diagram is introduced, and the magnitude of the ratio from this diagram is accurate and simple. Experimental results are in good agreement with theoretical predictions.

  • PDF

축소차원 Luenberger 관측기를 이용한 단상 PWM 컨버터의 고역률 제어 (The High Power Factor Control of a Single Phase PWM Converter using a Reduced-Order Luenberger Observer)

  • 양이우;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.529-535
    • /
    • 2000
  • In this paper, a current control system of a single phase PWM AC/DC converter using a reduced-order Luenberger observer without source voltage sensors is proposed. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the reduced-order Luenberger observer using actual currents and DC link voltage. The poles of the reduced-order Luenberger observer are placed in the left half plane of s-plane by the pole-placement method in order to acquire the stability of the observer. The magnitude and the phase of the estimated source voltage are used to accomplish the unity power factor. The proposed method is implemented by DSP(Digital Signal Processor). Experimental Results verify that the reduced-order observer estimates the source voltage without the estimation error and the control system accomplishes the unity power factor, and constant DC link voltage.

  • PDF