• Title/Summary/Keyword: connection bar

Search Result 163, Processing Time 0.026 seconds

Cyclic Loading Test for Beam-to-Column Connections of Concrete Encased CFT Column (콘크리트피복충전 각형강관 기둥-보 접합부의 주기하중 실험)

  • Park, Hong Gun;Lee, Ho Jun;Park, Sung Soon;Kim, Sung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.55-68
    • /
    • 2014
  • In this study, the beam-to column connections of concrete-encased-and-filled steel tube columns were tested under cyclic loading. Two specimens using steel beams and two specimens using precast concrete beams were tested. The dimension of the column cross section was $670mm{\pm}670mm$. The beam depths were 488mm and 588mm for the steel beams and 700mm for the precast concrete beams. The longitudinal bar ratios of the precast concrete beams were 1.1% and 1.5%. For the connections to the steel beams, continuity plates were used in the tube columns. For the connections to the PC beams, couplers were used for beam re-bar connections. The test results showed that except for a specimen, deformation capacities of the specimens were greater than 4% rotation angle, which is the requirement for the Special Moment Frame. Particularly, specimens using precast concrete beam showed excellent performances in the strength, deformation, and energy dissipation.

Performance Evaluation of the Stair Joints Constructed with Partial Precast Concrete System (프리캐스트 콘크리트 계단 접합부의 접합방식에 따른 성능평가)

  • Chang, Kug-Kwan;Lee, Eun-Jin;Jin, Byung-Chang
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.833-840
    • /
    • 2008
  • The time and cost can be reduced when applying partial precast concrete to the stair system in comparison to the cast-in-place or precast method. Because the performance of staircase which is used for evacuation can be largely different from connection types of precast concrete member, we tried to know structural behavior and performance evaluation according to each type of stair joints by experimental study. In the cast-in-place rigid joint, much reinforcement is needed in the end portion because much stress is concentrated in the middle portion. Also, in the pin joint which is used in the connection point, the maximum stress occurs in the middle point, so not only the amount of re-bar is increased but also the serviceability is largely decreased. The bolt type of semi-rigid joints proposed in this study had been increased strength and serviceability which is similar to the rigid joints. Also, its ductility was shown about 0.7 times in comparison to the rigid type and was about 2.8 times for the pin joint type. According to the classification of joint in Eurocode, it can be considered that it is one of the semi-rigid joints which are in the semi-rigid-full strength, and the structural behavior can be expected by using a model which applied to stiffness value decreased by 40 percent.

A Study on the properties of flexural behavior according to reinforcing method of Composite Beams of different types of structure (이질 구조부 보강방법에 따른 혼합구조보의 휨거동 특성에 관한 연구)

  • Lim, Byung Ho;Park, Jung Min;Kim, Wha Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.419-431
    • /
    • 2001
  • This study was to investigate structural behavior of composite structure beams composed of end-RC. center-Steel according to respective reinforcing method for connection zone composed of different materials (SRC) while attaching main bars on steel-flange by welding. The main reinforcing methods are as follows ; non-reinforcing, vertical shear reinforcing (type-stirrup), inclined reinforcing(type-x), horizontal reinforcing(type-web, 0.3L), double horizontal reinforcing (type-web, 0.3L), vertical reinforcing (type-flange, 0.3L). Consequently, It showed little difference in structural properties like ductility and strength according to the attaching method of main bars. For Maximizing the structural properties of composite beam, the most effective methods were vertical reinforcing one and double horizontal reinforcing one.

  • PDF

Heat load characteristic analysis of conduction cooled 10kJ HTS SMES (전도 냉각형 10kJ 고온 초전도 에너지 저장장치의 열 부하 특성 해석)

  • Kim, Kwang-Min;Kim, A-Rong;Kim, Jin-Geun;Park, Hae-Yong;Park, Min-Won;Yu, In-Keun;Kim, Seok-Ho;Sim, Ki-Deok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2219_2220
    • /
    • 2009
  • The characteristics of the Superconducting Magnetic Energy Storage (SMES) system are faster response, longer life time, more economical, and environment friendly than other Uninterruptible Power Supply (UPS) using battery. Fast charge and discharge time of SMES system can provide powerful performance of improving power quality in the grid. In order to demonstrate the effectiveness of SMES, the authors make a 10kJ SMES system for connection with RTDS (Real Time Digital Simulator). Because the characteristics of superconducting magnet are very important in SMES system, the necessary items such as thermal characteristic, mechanical stress and protection circuit should be considered. In this paper, the authors experimented thermal characteristics of the 10kJ SMES system. The experiment was accomplished using a simulation coils made of aluminium. It has same dimension of the 10kJ class HTS SMES coil. The coil was cooled with GM (Gifford -McMahon) cryocooler through the OFHC (Oxgen Free High thermal Conductivity) conduction bar. The test results of cool down and heat loads characteristics of the simulation coils are described in detail.

  • PDF

Stud reinforcement in beam-column joints under seismic loads

  • Abdollahzadeh, Gholamreza;Ghalani, Saeed Eilbeigi
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.297-317
    • /
    • 2016
  • Current codes recommend large amounts of shear reinforcement for reinforced concrete beam-column joints that causes significant bar congestion. Increase in congestion of shear reinforcement in joint core (connection zone), leads to increase accomplishment problems. The congestion may also lead to diameter limitations on the beam bars relative to the joint dimensions. Using double headed studs instead of conventional closed hoops in reinforced concrete beam-column joints reduces congestion and ensures easier assembly of the reinforcing cage. The purpose of this research is evaluating the efficiency of the proposed reinforcement. In this way, 10 groups of exterior beam-column joints are modeled. Each group includes 7 specimens by different reinforcing details in their joint core. All specimens are modeled by using of ABAQUS and analyzed subjected to cyclic loading. After verification of analytical modeling with an experimental specimen, 3D nonlinear specimens are modeled and analyzed. Then, the effect of amount and arrangement of headed studs on ductility, performance, ultimate strength and energy absorption has been studied. Based on the results, all joints reinforced with double headed studs represent better performance compared with the joints without shear transverse reinforcement in joints core. The behavior of the former is close to joints reinforced with closed hoops and cross ties according to the seismic design codes. By adjusting the arrangement of double-headed studs, the decrease in ductility, performance, ultimate moment resistant and energy absorption reduce to 2.61%, 0.90%, 0.90% and 1.66% respectively compared with the joints reinforced by closed hoops on the average. Since the use of headed studs reduces accomplishment problems, these amounts are negligible. Therefore, use of double-headed studs has proved to be a viable option for reinforcing exterior beam-column joints.

Evaluation on Cyclic Flexural Behavior of HSRC (Hybrid H-steel-reinforced Concrete) Beams Connected with Steel Columns (강재 기둥과 하이브리드 강재 보-RC 보 접합부의 반복 휨 거동 평가)

  • Kwon, Hyuck-Jin;Yang, Keun-Hyeok;Hong, Seung-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.291-298
    • /
    • 2017
  • The objective of the present study is to evaluate the cyclic flexural behavior of a hybrid H-steel-reinforced concrete (HSRC) beam at the connection with a H-steel column. The test parameter investigated was the configuration of dowel bars at the joint region of the HSRC beam. The HSRC beam was designed to have plastic hinge at the end of the H-steel beam rather than the RC beam section near the joint. All specimens showed a considerable ductile behavior without a sudden drop of th applied load, resulting in the displacement ductility ratio exceeding 4.6, although an unexpected premature welding failure occurred at the flanges of H-steel beams connecting to H-steel column. The crack propagation in the RC beam region, flexural strength, and ductility of HSRC beam system were insignificantly affected by the configuration of dowel bars. The flexural strength of HSRC beam system governed by the yielding of H-steel beam could be conservatively evaluated from the assumption of a perfect plasticity state along the section.

Leadframe SiP with Conformal Shield

  • Kim, ByongJin;Sim, KiDong;Hong, SeoungJoon;Moon, DaeHo;Son, YongHo;Kang, DaeByoung;Khim, JinYoung;Yoon, JuHoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.31-34
    • /
    • 2016
  • System In Package (SiP) is getting popular and momentum for the recent wearable, IoT and connectivity application apart from mobile phone. This is driven by market demands of cost competitive, lighter and smaller/thinner and higher performance. As one of many semiconducting assembly products, Leadframe product has been widely used for low cost solution, light/ small and thin form factor. But It has not been applied for SiP although Leadframe product has many advantages in cost, size and reliability performance. SiP is mostly based on laminate substrate and technically difficult on Leadframe substrate because of a limitation in SMT performance. In this paper, Leadframe based SiP product has been evaluated about key technical challenges in SMT performance and electrical shield technology. Mostly Leadframe is considered not available to apply EMI shield because of tie-bar around package edge. In order to overcome two major challenges, connection bars were deployed properly for SMT pad to pad and additional back-side etching was implemented after molding process to achieve electrical isolation from outer shield coating. This product was confirmed assembly workability as well as reliability.

A Study on the Analysis of Relational to Using Status and Connection with Space in Public Space of Platoon Kunsthalle (플래툰 쿤스트할레의 공공공간의 사용자현황 및 공간과의 관계 분석에 관한 연구)

  • Yi, Bo-Hyeon;Suh, Kuee-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.217-225
    • /
    • 2011
  • The meaning and role of public space has existed based on the periodical situation like history. The more the time has passed, the faster the meaning of it has changed. We can see the differences of it from the one which used to be. This study is about Platoon Kunsthalle which is so-called the complex cultural space. The purpose of this study is to show how the user is related to the program for the planning of the public space. It is based on the procedure of the research with absorbing the place. The people who are using the space are absorbed for knowing the user's action. And then, the specific actions are written and the status of the using space is photographed. The research is based on asking and answering about that. The result of this study is as follows : The first is that young people between 20's and 30's are using a hall comparing with other age through daily using of space and features of users. Also, Using between 7p.m. and 9p.m., a dinnertime, takes the first place and using of meals and beverages is major at lunch due to restaurant and bar. User behavior of "sitting" is the biggest part and the hall is used for the public purpose connected with "talking". The second is that the daily hall space is classified with the spacial area indirectly based on the condition. Also, it depends on the time and the using. The third is that the unusual hall space is depended on the program which is the role of leading the extention of using the space. That is why the program is important because it is effected directly to the way of using the space and the place of the furniture. I am looking forward that this study is the basic data for the planning of the public space in the complicated culture.

Determination of structural performance of 3D steel pipe rack suspended scaffolding systems

  • Arslan, Guray;Sevim, Baris;Bekiroglu, Serkan
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.671-681
    • /
    • 2017
  • This study investigates the structural performance of 3D steel pipe rack suspended scaffolding systems. For the purpose, a standard full scale 3D steel pipe rack suspended scaffolding system considering two frames, two plane trusses, purlins and wooden floor is constructed in the laboratory. A developed load transmission system was placed in these experimental systems to distribute single loads to the center of a specific area in a step-by-step manner using a load jack. After each load increment, the displacements are measured by means of linear variable differential transducers placed in several critical points of the system. The tests are repeated for five different system conditions to determine the structural performance. The means of system conditions is the numbers of the tie bars which are used to connect plane trusses under level. Finite elements models of the 3D steel pipe rack suspended scaffolding systems considering different systems conditions are constituted using SAP2000 software to support the experimental tests and to use the models in future studies. Each of models including load transmission platform is analyzed under a single loading and the displacements are obtained. In addition, to calibrate the numerical models some uncertain parameters such as elasticity modulus of wooden floor and connection rigidity of purlins to plane trusses are assessed experimentally. The results of this work demonstrate that when increasing numbers of tie bars the displacement values are decreased. Also the results obtained from developed numerical models have harmony with those of experimental. In addition, the scaffolding system with two tie bars at the beginning and at the end of the plane truss has the optimum structural performance compared the results obtained for other scaffolding system conditions.

A Study on the Creative Interface Factors of Library Space on Ito Toyo - Focus on the Tama Art University New Libraries - (이토토요의 도서관 공간에 나타나는 창조적 인터페이스요소에 관한 연구 - 타마미술대학신도서관을 사례로 -)

  • Hwang, Mee-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.205-213
    • /
    • 2010
  • The importance of communication which is oriented to interaction, fusion and connection is more increased in the post-information society. The information environment is already realized as interface to reach immediately and freely to the databased information and knowledge. The contemporary libraries execute very important roles as an intellectual infra of modern times to deliver the great human achievement and create new culture. In the mean time, the rapid information-oriented society and the development of digital technology bring out big change in the traditional dispatch and receipt method of information. For this reason, libraries as the community space of visitors integrates physical space - electronic space and reconstructs new temporary culture and value to build the new interface that connects human to human, human to space and human to information. On the premise of these awareness, this study analysis the creative interface factor of Tama Art University New Libraries in Ito Toyo in order to research the function and the application method of modern libraries. And the results are follows. 1)We can make sure the significance of communication and the integration consciousness between digital technology and analogue sensitivity that is the characteristic of the post-information society. 2)We can classify for the creative interface factors by the character as space factor(Arcade, Gallery, Lounge, AV Booth, Cafe), facility/equipment factor(Laboratory, Media, Bar, Info Shelf, Media Seat) and furniture factor(Carrel, Desk, Mag Table, XI Shelf). 3)We can see that these interface factors change the stream of library users and that the library is constructed for library users to create and discovery something easily from books and modern technologies. And we can realize also that these factors are creative installation to lead out naturally the latent liberty sense of users.