• 제목/요약/키워드: connected component

검색결과 533건 처리시간 0.436초

Enhanced Startup Diagnostics of LCL Filter for an Active Front-End Converter

  • Agrawal, Neeraj;John, Vinod
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1567-1576
    • /
    • 2018
  • The reliability of grid-connected inverters can be improved by algorithms capable of diagnosing faults in LCL filters. A fault diagnostic method during inverter startup is proposed. The proposed method can accurately generate and monitor information on the peak value and the location of the peak frequency component of the step response of a damped LCL filter. To identify faults, the proposed method compares the evaluated response with the response of a healthy higher-order damped LCL filter. The frequency components in the filter voltage response are first analytically obtained in closed form, which yields the expected trends for the filter faults. In the converter controller, the frequency components in the filter voltage response are computed using an appropriately designed fast Fourier transform and compared with healthy LCL response parameters using a finite state machine, which is used to sequence the proposed startup diagnostics. The performance of the proposed method is validated by comparing analytical results with the simulation and experimental results for a three-phase grid-connected inverter with a damped LCL filter.

Reliability-based design of semi-rigidly connected base-isolated buildings subjected to stochastic near-fault excitations

  • Hadidi, Ali;Azar, Bahman Farahmand;Rafiee, Amin
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.701-721
    • /
    • 2016
  • Base isolation is a well-established passive strategy for seismic response control of buildings. In this paper, an efficient framework is proposed for reliability-based design optimization (RBDO) of isolated buildings subjected to uncertain earthquakes. The framework uses reduced function evaluations method, as an efficient tool for structural reliability analysis, and an efficient optimization algorithm for optimal structural design. The probability of failure is calculated considering excessive base displacement, superstructure inter-storey drifts, member stress ratios and absolute accelerations of floors of the isolated building as failure events. The behavior of rubber bearing isolators is modeled using nonlinear hysteretic model and the variability of future earthquakes is modeled by applying a probabilistic approach. The effects of pulse component of stochastic near-fault ground motions, fixity-factor of semi-rigid beam-to-column connections, values of isolator parameters, earthquake magnitude and epicentral distance on the performance and safety of semi-rigidly connected base-isolated steel framed buildings are studied. Suitable RBDO examples are solved to illustrate the results of investigations.

원자력발전소 변압기 연결 선로 결상 검출 시스템 (Open-Phase Condition Detecting System for Transformer Connected Power Line in Nuclear Power Plant)

  • 하체웅;이도환
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.254-259
    • /
    • 2015
  • On January 30, 2012 an auxiliary component of Byron Unit 2 was tripped on bus under voltage. The cause of the event was the failure of the C-phase insulator track for the Unit 2 station auxiliary transformer(SAT) revenue metering transformer. In addition to this event, other events have occurred at other plants resulting in an open-phase condition.[1] Therefore, Nuclear Regulatory Commission(NRC) has requested that not only nuclear power plant(NPP) operating company but also its Design Certification(DC) applicant have to prepare open-phase detecting system in their operating plants and design document. In this paper, various open-phase conditions are simulated in NPP using Electromagnetic Transient Program(EMTP) and Atpdraw, and open-phase condition detecting system is proposed for Main Transformer(MT), Unit Auxiliary Transformer(UAT) and SAT connected power line in NPP.

Zirconium Titanate Thin FIlm Prepared by Surface Sol-Gel Process and Effects of Thickness on Dielectric Property

  • Kim, Chy-Hyung;Lee, Moon-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권5호
    • /
    • pp.741-744
    • /
    • 2002
  • Single phase of multicomponent oxide ZrTiO4 film could be prepared through surface sol-gel route simply by coating the mixture of 100 mM zirconium butoxide and titanium butoxide on $Pt/Ti/SiO_2Si(100)$ substrate, following pyro lysis at $450^{\circ}C$, and annealing it at 770 $^{\circ}C.$ The dielectric constant of the film was reduced as the film thickness decreased due to of the interfacial effects caused by layer/electrode and a few voids inside the multilayer. However, the dielectric property was independent of applied dc bias sweeps voltage (-2 to +2 V).The dielectric constant of bulk film, 31.9, estimated using series-connected capacitor model was independent of film thickness and frequency in the measurement range, but theoretical interfacial thickness, ti, was dependent on the frequency. It reached a saturated ti value, $6.9{\AA}$, at high frequency by extraction of some capacitance component formed at low frequency range. The dielectric constant of bulk ZrTiO4 pellet-shaped material was 33.7 and very stable with frequency promising as good applicable devices.

Utility-Connected Solar Power Conditioner Using Edge-Resonant Soft Switching Duty Cycle Sinewave Modulated Inverter Link

  • Ogura, Koki;Chandhaket, Srawouth;Nakaoka, Mutsuo;Terai, Haruo;Sumiyoshi, Shinichiro;Kitaizumi, Takeshi;Omori, Hideki
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.181-188
    • /
    • 2002
  • The utility interfaced sinewave modulation Inverter for the solar photovoltaic power conditioner with a high frequency transformer is presented for residential applications. As compared with the conventional full-bridge hard switching slnewave PWM inverter with a high frequency link, the simplest single-ended edge-resonant soft switching sinewave inverter with a sinewave duty cycle pulse control scheme is implemented, resulting in size and weight reduction, low cost and high efficiency This paper presents a prototype system of the sinewave zero voltage soft switching sinewave inverter for solar power conditioner, along with its operating principle and unique features. In addition to these, this paper discusses a control implementation to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed and evaluated from an experimental point of view A newly developed utility-connected sinewave power conditioning circuit which achieves 92.5% efficiency under 4kW output is demonstrated.

50kW급 계통연계형 태양광발전시스템의 성능모니터링 결과 및 평가분석 (Performance Monitoring Results, Evaluation and Analysis of 50kW Grid-Connected PV System)

  • 소정훈;유병규;황혜미;유권종;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2007
  • Monitoring system is constructed for evaluating and analyzing performance of installed 50kW grid-connected PV system and have been monitored since October 2005. As climatic and irradiation conditions have been varied through long-term operation, there is necessity for evaluating numerical values of PV(Photovoltaic) system performance to observe the overall effect of environmental conditions on their operation characteristics. This paper presents performance monitoring results and analysis on component perspective(PV array and power conditioning system) and global perspective(yield, losses) of PV system for one year monitoring periods.

소형 추적 레이다 와이어 하네스 설계 (Wire Harness Design of Compact Tracking Radar)

  • 김홍락;김윤진;우선걸;안세환
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권4호
    • /
    • pp.35-41
    • /
    • 2020
  • 소형 추적 레이다는 여러 구성품들이 유기적으로 연결되어 있어서 와이어 하니스 설계가 매우 중요하다. 구동부 위인 김발을 지나서 안테나와 초고주파수신기로 연결되는 배선은 연결되는 path에 따라서 전기적 특성에 영향을 준다. 또한 김발의 구동 성능에도 영향을 미친다. 디지털 신호가 많은 신호처리부 및 서보부와 연결되는 케이블은 전자파 노이즈에 의하여 신호처리부의 CPU가 오동작을 하지 않도록 대책을 마련해야 한다. ◯◯ GHz 대역의 신호전송을 위한 케이블은 온도, 진동, 충격에 대한 설계가 반영되어야 한다. 좁은 공간에 와이어 하네스를 설계하기 위해서는 컨넥터의 크기를 최소화 해야 한다. 본 논문에서는 소형 추적 레이다의 와이어 하네스 설계에 고려해야 할 사항들에 대하여 설명하고 설계 방안을 제시하였다.

우리나라 우편 봉투 영상에서의 주소 영역 추추을 위한 지식 기반 시스템 (A Knowledge-Based System for Address Block Location on Korean Envelope Images)

  • 김기철;이성환
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.137-147
    • /
    • 1994
  • In this paper,we propose a knowledge-based system for locating Destination Address Block(DAB) by analyzing the structure of Korean envelope images. In the proposed system the preprocessing steps such as adaptive binarization connected component extraction and deskewing are carried out first for the effective structure analysis of the envelope image. Then DAB containing address name and zipcode parts of the input envelope image is extracted by an iterative procedure based on the knowledge acquired from the statistical feature analysis of the various envelope images. Most of the system for slocating address blocks on envelopes have extracted DAB by segmenting an envelope image into several candidate blocks followed by selecting one among the candidate blocks. Because it is very difficult to segment a Korean envelope image into several blocks due to the specific writing habits that the addresses on the envelope are written in close proximity to each other the proposed iterative procedure determines DAB by splitting or merging the connected components and verifies the determined DAB without segmentation and selection. Experiments with a great number of the live envelopes provided from Seoul Mail Center in Koorea were carried out. The results reveal that the proposed system is very effective for address block location on Korean envelopes.

  • PDF

3상 계통 연계형 인버터의 역상분 전류 주입을 이용한 계통 등가 임피던스 추정 기법 (Equivalent Grid Impedance Estimation Method Using Negative Sequence Current Injection in Three-Phase Grid-connected Inverter)

  • 박찬솔;송승호;임지훈
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.526-533
    • /
    • 2015
  • A new algorithm is proposed for the estimation of equivalent grid impedance at the point of common coupling of a grid-tie inverter output. The estimated impedance parameter can be used for the improvement of the performance and the stability of the distributed generation system. The estimation error is inevitable in the conventional estimation method because of the axis rotation due to PLL. In the conventional estimation error, the d-q voltage and current are used for the calculation of the impedance with active and reactive current injections. Conversely, in the proposed algorithm, the negative sequence current is injected, and then the negative sequence voltage is measured for the impedance estimation. As the positive and negative sequence current controller is independent and the PLL is based on the positive sequence component only, the estimation of the equivalent impedance can be achieved with high accuracy. Simulation and experimental results are compared to validate the proposed algorithm.

K-Band용 SEmi-MMIC Hair-pin 공진발진기 (A Semi-MMIC Hair-pin Resonator Oscillator for K-Band Application)

  • 이현태
    • 한국통신학회논문지
    • /
    • 제25권9B호
    • /
    • pp.1635-1640
    • /
    • 2000
  • 본 논문에서는 기본파를 억제시키고 2차 고조파가 주 발진신호로 동작되는 18GHz 대역의 push-push 발진기를 semi-MMIC 형태로 설계 및 제작하였다. 마이크로스트립 선로를 포함하는 passive component는 semi-insulating GaAs 기판위에 MMIC 공정을 이용하여 구현하고, Chip 형태의 P-HEMT, 저항, 캐패시터를 Au wire-bonding에의해 연결하였으며, via-hole 대신 접지면을 회로 주변에 구성하여, back-side와 wire-bonding하였다. 실험 결과 -10.5 dBm의 출력 전력 특성을 얻었으며, 기본 주파수 억압은 -17.3 dBc/Hz의 특성을 보였다. 위상 잡음은 100kHz offset에서 -97.7 dBc/Hz를 얻었다.

  • PDF