• Title/Summary/Keyword: connect

Search Result 2,472, Processing Time 0.031 seconds

A Study on the Historical Developments of References on Cataloging Rules (목록규칙상에서 참조의 변천과정에 관한 연구)

  • 이양숙
    • Journal of Korean Library and Information Science Society
    • /
    • v.34 no.4
    • /
    • pp.227-252
    • /
    • 2003
  • This study is to analyze the historical developments of references on cataloging rules. References is named cross reference on The Panizzi' and Jewett' Report and defined at Rules for a Dictionary Catalog by Charles A. Cutter. References is developed to “see reference”, “see-also reference”, “name-title reference”, and “explanatory reference” on AACR2. References have traditionally been regarded as syndetic devices, making it possible to retrieve and connect related works. Conclusionally, it functions as a tool which directly connect all the works related but in different formats of a same author name and a same title name. In online catalogues, it means that the role and function of references have increasingly become extended to be very important.

  • PDF

A Feasibility Study on TETRA System Application for Train Control Systems

  • Tsogtbayar, Chinzorig;Kang, Hyoungseok;Lee, Jongwoo;Boldbaatar, Tsevelsuren
    • International Journal of Railway
    • /
    • v.9 no.2
    • /
    • pp.36-40
    • /
    • 2016
  • TETRA communication system is very versatile system which can transmit voice + data and packet data optimized. Direct mode operation permits to connect between mobiles when mobile stain is out of coverage of networks. It can be more secure communication channel for railway signaling systems. Railway signaling systems use many of wayside signal equipment, which require many maintenance efforts and budget. Many railway authorities want to reduce and replace the wayside equipment. Radio based signaling systems are one of candidate for replacing the conventional signaling systems. The radio based signaling systems can replace track circuit and wayside signal. The radio systems permit to connect between control centers and trains. The radio systems have to ensure high quality of the connectivity more or equal to the existed track circuits. We studied the application of TETRA systems for railway radio systems for bridging between train control centers and trains. We provide an operation scenario for radio based train control system to ensure the safety require to the existed trains control system and satisfied the existed operational availability. We showed the data transmission speed, maximum bit error rate, and data coding for the radio-based signal system using TETRA systems.

IoL Field Gateway: An Integrated IoT Agent using Networked Smart LED Lighting Controller

  • Mariappan, Vinayagam;Jung, Soonho;Lee, Sangwoon;Cha, Jaesang
    • Information and Communications Magazine
    • /
    • v.34 no.2
    • /
    • pp.12-19
    • /
    • 2017
  • The LED technology advancement introduce cuttingedge technology on Internet of Things (IoT) to connect the physical world to the digital realm, using digital smart lighting infrastructure called Internet of light (IoL). This paper proposes an Integrated IoT agent on networked smart LED lighting controller called IoL Filed Gateway using lighting infrastructure in which a lighting system that can connect to a network and can be monitored and controlled from a centralized system or via the cloud. The IoL Field Gateway defines new world of smart connected intelligence, lighting can become an integral and responsive part of everyday human life environments. The proposed connected lighting gateway uses the concept of multi-hop ad hoc network using visible light communication (VLC) with RF wireless technologies and Wired PLC (Power Line Communication). This connectivity and intelligence integrated into LED-based luminaires form the backbone of smart buildings and cities and make the Internet of Things (IoT) vision feasible and enables the lighting administrator can control numerous lightings easily and visitors can get visual information from the lightings with their smart devices. The proposed IoL gateway design is emulated on Arduino based HW platform with VLC, RF, and PLC connectivity and evaluated with four sensor interface.

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

Development of Friction Welded Al to Cn Bimetallic Sleeve for 220kV XLPE Cable Termination & Joint (220kV XLPE CABLE 접속함용 Al-Cu 이종접속슬리브 개발)

  • Kim, Hyun-Ju;Park, Jeong-Ki;Park, Sung-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.93-93
    • /
    • 2010
  • We developed friction welded bimetallic sleeve for 220kV aluminum conductor XLPE cable. Not only friction welded bimetallic sleeve for Termination(EB-A, EB-G) but also friction welded sleeve for Joint of Al to Cu conductor was developed regardless of this project. Generally, friction welded sleeve used to connect Al conductor cable to Cu conductor cable and used for improvement of mechanical property of terminal by offer the copper side of friction welded bimetallic sleeve at the Termination. Connection method for Al-Cu conductor has mainly used friction welding at the solid state, because it is difficult to connect by using conventional welding method. this investigation introduces development of friction welded bimetallic sleeve by friction welding and test result of 220kV Al conductor XLPE cable and accessories using friction welded sleeve.

  • PDF

AICPS Management Network Integration (PC 통신 서비스 상호 접속 시스템(AICPS)의 통합 관리망)

  • Hong, Yong-Pio;Yun, Sung-Je;Lee, Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.11-21
    • /
    • 1999
  • Physically, AICPS consists of HSSF(High Speed Switching Fabric) and various types of service interface modules to support services of homogeneous communication networks. Functionally, AICPS consists of UANS(User Access Network Subsystem) to connect users with communication networks, IDNS(Information Delivery Network Subsystem) to connect Information-Providers with information delivery network, and LOMS(Local Operations and Management System to manage AICPS. This paper describes the structures of LOMS, ONAS(Operational Network Access Subsystem), which interfaces between LOMS and HSSF, and describes reliability improvement algorithms and construction methods of nationwide management structure of AICPS.

  • PDF

Design Method and Preliminary Data Analysis of Subscale Direct-Connect Test Facility for Liquid Ramjet Combustor (I) (액체 램제트 엔진용 소형 연소기 직접 연결식 시험장치의 설계 방법과 시험 데이터 분석 (I))

  • 성홍계;김인식;이규준;김경무;이도형;변종렬;황용석;오석진;한정식
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.59-63
    • /
    • 2003
  • This paper describes the conceptual design method of subscale direct-connect test facility for liquid fuel ramjet combustion study and preliminary analysis of test results. The measured pressure signal represents the successful operation of the test facility. The pressure oscillation in combustion chamber shows the dominant frequency of 190Hz, relatively very low frequency to 1L acoustic mode (1200Hz) based on the length of combustor. It is suspected that there were several driving sources, which are vortex street at backward step of combustor, inlet resonance induced by the long length of unchecked inlet, and/or combustor configuration with optical window.

  • PDF

Connect Attachment of Fixed Segmented Bridge (고정성 분할 브릿지의 연결 어태치먼트)

  • Kim, Nam-Joong
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.127-138
    • /
    • 2002
  • There are some cases that dental prosthesis does not operate as properly as expected in oral mouth. The reasons are such as a distortion of the mandibular, a fault of impression taking system or an extrusion of remaining teeth. One of dental prostheses to consider in the situations is the attachment which connects segment bridge. Active discussions are managed on theoretical side of this field but few on clinical side of it, which must be considered first. Accordingly I'd like to suggest a theoretical background for connect attachment of fixed segmented bridge. 1. As a bridge gets longer, burden on dental ligament is increased and the hardness of a bridge is lessened. 2. The flexibility of a bridge increases in ratio to 3 multiplication of the length and decreases in ratio to 3 multiplication of the width of occlusal surface and base of pontic. 3. Precision rest is needed to cope with the shake of teeth and the difference of axis direction among abutments. 4. Female part of the precision rest should be on middle abutment distal and male one on mesial of pontic. 5. Segmented attachment can be efficiently used to cope with long span bridgework and also in case that one piece casting can't be done because of slant of abutment.

  • PDF

Using habitat suitability model for the wild boar (Sus scrofa Linnaeus) to select wildlife passage sites in extensively disturbed temperate forests

  • Rho, Paikho
    • Journal of Ecology and Environment
    • /
    • v.38 no.2
    • /
    • pp.163-173
    • /
    • 2015
  • The occurrence of wild boars (Sus scrofa Linnaeus) and reports of wildlife-vehicle conflicts (i.e., road-kill) involving them have increased in natural forest regions of Korea. In the past few decades, many wildlife passages have been constructed to reduce vehicle collisions involving wildlife species. However, few studies have assessed the habitat suitability of target wildlife species when locating the construction sites of wildlife passages. Target species rarely use wildlife passages if built in an inappropriate location. Therefore, a quantitative habitat model is required to find suitable sites for wildlife passages that can connect the fragmented forest patches of wildlife habitats in Korea. In this study, the wild boar was selected as the target species, and six environmental variables (percentage of Quercus forest, slope aspect, distance to roads, water accessibility, forest stand age and density) were measured. The habitat model for wild boars was developed with a Delphi survey, and habitat suitability maps were delineated for the provinces of Gangwon-do and Jeollanam-do. In this study, 298 and 64 boars were observed in Gangwon-do and Jeollanam-do, respectively. Observations of wild boars derived from the second nationwide natural environmental survey were used to evaluate the habitat model. Habitat suitability maps that superimposed existing road networks suggested that wild boar habitats were severely fragmented in both provinces, particularly in Gangwon-do. To connect the fragmented habitats and prevent wildlife-vehicle collisions, this study proposes 11 and 5 wildlife passage sites in Gangwon-do and Jeollanam-do, respectively.

Influence of connection detailing on the performance of wall-to-wall vertical connections under cyclic loading

  • Hemamalini, S.;Vidjeapriya, R.
    • Advances in concrete construction
    • /
    • v.9 no.5
    • /
    • pp.437-448
    • /
    • 2020
  • In high rise buildings that utilize precast large panel system for construction, the shear wall provides strength and stiffness during earthquakes. The performance of a wall panel system depends mainly on the type of connection used to transfer the forces from one wall element to another wall element. This paper presents an experimental investigation on different types of construction detailing of the precast wall to wall vertical connections under reverse cyclic loading. One of the commonly used connections in India to connect wall to wall panel is the loop bar connection. Hence for this study, three types of wet connections and one type of dry connection namely: Staggered loop bar connection, Equally spaced loop bar connection, U-Hook connection, and Channel connection respectively were used to connect the precast walls. One third scale model of the wall was used for this study. The main objective of the experimental work is to evaluate the performance of the wall to wall connections in terms of hysteretic behaviour, ultimate load carrying capacity, energy dissipation capacity, stiffness degradation, ductility, viscous damping ratio, and crack pattern. All the connections exhibited similar load carrying capacity. The U-Hook connection exhibited higher ductility and energy dissipation when compared to the other three connections.