• Title/Summary/Keyword: connect

Search Result 2,472, Processing Time 0.032 seconds

Evaluation on the Possibility of Connection Between IFC and Digital Quantity DataBase Exchange Standard (IFC와 디지털 수량산출정보 교환표준의 연계 가능성 평가)

  • Won, Ji-Sun;Moon, Jin-Seok;Choi, Won-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6488-6494
    • /
    • 2013
  • Recently, BIM has attracted attention as a technology to improve the construction productivity. The BIM standards to be applied to the BIM project are necessary for using or connecting the current 2D-based drawing standards. To develop the standard for BIM-based QTO and cost, this paper focused on using QDBEx, which was applied to road project cost management and connecting QDBEx with IFC, which is the BIM data delivery format. The IFC schema was evaluated to determine if it is possible to use the converts to the QDBEx XML file. As a result, 66% of the whole was available to connect directly, and 17% was available to connect through the processing of instance. The remaining 17% was evaluated to determine if it was available to connect. In the future, improvements in the schema will be suggested based on these results.

The Effect of Crosstalk and Loss on the Scaliability and Transmission Performance of Optical Cross-Connect Nodes (광상호분배기 노드에서 누화와 손실을 고려한 전송성능 및 확장성 분석)

  • Lee, Sang-Rok;Seo, Wan-Seok;Yoon, Byeong-Ho;Lee, Sung-Un;Lee, Jong-Hyun
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.11
    • /
    • pp.15-21
    • /
    • 1999
  • The scalability of optical cross-connect nodes is analyzed based on the limiting factor of transmission performance. The limiting factors considered are ASE noise accumulation and gain saturation in the optical amplifiers, and crosstalk in both wavelength multiplexers/demultiplexers and optical switches. When the wavelength multiplexer/demultiplexers crosstalk is lower than 25dB, Power Penalty is below 1dB for the cascaded transmission of 10 nodes with 4 input/output ports. When 10Gbps signals are transmitted through nodes with 4 and 16 input/output Ports, performance degradation due to switch crosstalk is dominant compared to that due to ASE noise accumulation if the switch crosstalk is larger than 30dB and 45dB, respectively. For the single stage transmission of 10Gbps signal with 21dB fiber link loss, the maximum loss of optical cross-connect nodes must be under 34dB to achieve the BER of $10^{-12}$.

  • PDF

Development of Open-Connect Type Eddy Current Transducers for the Detection of Surface Flaws in Continuous Pipeline (연속된 배관의 결함 검출을 위한 개폐식 와전류 탐촉자 개발)

  • Kim, Young-Joo;Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.187-192
    • /
    • 2002
  • The open-connect type eddy current transducer for the flaw detection in continuously connected pipelines was developed. This eddy current transducer is for the on-line inspection of the tubes in industries, to which commercial encircling probes are not applicable. The excitation coil that consists of a ribbon type cable and a flat connector can be opened and closed on purpose. The sensing coils of this transducer are circumferentially arrayed near the outside of the tube wall but axially displaced from the exciter by about one and half tube diameter. In application to steel tubes, and the performance of this transducer was evaluated as a little behind those of magnetic saturation type in signal to noise ratio and flaw size decision, but usable to detect or to locate large size flaws in steel tubes. Surface cracks deeper than 19% of the tube thickness could be detected with good signal to noise ratio.

Definition of New SIBs for Service Description and Implementation of SCE in Intelligent Network (지능망에서 서비스 기술을 위한 새로운 SIB들의 정의와 SCE의 구현)

  • 김연중;이지영;마영식;안순신
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.2
    • /
    • pp.209-220
    • /
    • 2004
  • The Goals of Intelligent Network(IN) provide the methods that create, test and apply the various hinds of services to satisfy the user's need. In this environments, we can create new IN service by description of GSL(Global Service Logic) using that SCE(Service Creation Environment). In the ITU-T CS-2, the various SIBs(Service Independent Building-blocks) are defined to develop the services. There are limitations to develop the various services using the SIBs defined in recommendation. So, in this paper, we define the new SIBs and implement the SCE. The new SIBs are defined in this paper are Connect SIB and BCSM Event SIB. The Connect Call SIB provides the connectivity between SLPI(Service Logic processing Program Instance) and call after connecting the calling party to called party. The BCSMEvent SIB provides the functions that request SSF to report the call processing event and receive it. In this paper, we design and implement the SCE that supports the SIBs defined by recommendation and this paper, provides GUI environment to specify GSI, and generates the code used by SCP.

Unified app architecture for plug and play of smart phone accessary (스마트폰용 USB 액세서리 Plug and Play를 위한 통합 앱 구조)

  • Kang, Sun Goo;Chae, Yi Geun;Eun, Sung Bae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.470-475
    • /
    • 2014
  • Recently, smart phones are spread out as a universal mobile terminal equipment. Its provide USB interface to connect with various devices. Smart phones may be replaced with high priced monitoring equipments because of portability and mobility as its merit. In addition to that, the various sensor devices detecting surrounding environment of the radioactivity, sodium or electromagnetic waves have been announced. But the plug and play methods of sensor devices have some problem to connect smart phone with USB accessory device. We propose an integrated methodology that can connect smart phone with USB sensor devices and also, we realized USB accessory plug and play with one App that can collect measurement data through various sensor devices.

A Study on Smart Door Lock using Internet of Things (IoT를 이용한 스마트 도어락에 관한 연구)

  • Kim, Jang-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.539-544
    • /
    • 2020
  • The research is on progressing to operate digital door lock with the method to guarantee the security and safety in the meantime to use digital door lock conveniently using Internet of Things (IoT) standardizing various service providing technology using IoT in home network currently. In this study, compose home network interconnecting Raspberry-PI and web server reflection this trend and composed the system to control the door lock after connect Arduino substituting converter function. Making Raspberry-PI using dynamic IP address using existing open source easily maintain DNS information and possible to connect internet network in home network ethernet and finally, making the smartphone can control door lock remotely entering designated address after connect the internet. The connection between home network and Arduino is executed by Raspberry-PI and bluetooth pairing as 1:1 and make random user's access to be impossible. Especially, to make open/close the door lock with smartphone not by using password on the keypad or using RFID card is judged as the method increasing the security make random user's access to be impossible and also increased the usefulness making remote control to be possible.

Acoustic Interface Element on Nonconformal Finite Element Mesh for Fluid-Structure Interaction Problem (비적합 유한요소망에 적용가능한 유체-구조물 연결 요소)

  • Cho, Jeong-Rae;Lee, Jin Ho;Cho, Keunhee;Yoon, Hyejin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2023
  • In the fluid-structure interaction analysis, the finite element formulation is performed for the wave equation for dynamic fluid pressure, and the dynamic pressure is defined as a degree of freedom at the fluid nodes. Therefore, to connect the fluid to the structure, it is necessary to connect the degree of freedom of fluid dynamic pressure and the degree of freedom of structure displacement through an interface element derived from the relationship between dynamic pressure and displacement. The previously proposed fluid-structure interface elements use conformal finite element meshes in which the fluid and structure match. However, it is challenging to construct conformal meshes when complex models, such as water purification plants and wastewater treatment facilities, are models. Therefore, to increase modeling convenience, a method is required to model the fluid and structure domains by independent finite element meshes and then connect them. In this study, two fluid-structure interface elements, one based on constraints and the other based on the integration of nonsmooth functions, are proposed in nonconformal finite element meshes for structures and fluids, and their accuracy is verified.

Effect of storage condition of resin cement on shear bond strength of the orthodontic bracket (레진시멘트의 보관 조건이 치열교정용 브라켓의 전단접착강도에 미치는 영향)

  • Seul-Gi, Yi;Jin-Woo, Kim;Se-Hee, Park;Yoon, Lee;Eung-Hyun, Kim;Kyung-Mo, Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.189-195
    • /
    • 2022
  • Purpose: For orthodontic bracket bonding, light curing resin cement is widely used because the process is convenient, and it can be polymerized at the desired time. This study compared the difference of bonding strength of orthodontic resin cement according to storage condition. Materials and Methods: After acid etching the bovine enamel surface with 37% phosphoric acid, 15 orthodontic brackets for mandible incisors were bonded with Ortho Connect and Orthomite LC according to following three conditions; 1) Immediate after 4℃ refrigeration for 3 months (IR), 2) One day room temperature after 4℃ refrigeration for 3 months (OR), 3) Room temperature for 3 months (RT). The shear bond strength was measured with a universal material tester and failure pattern of the specimen was observed. Two-way ANOVA and One-way ANOVA were used at the 95% significance level. Results: Ortho Connect that was applied immediately after refrigeration showed the maximum shear bond strength. Orthomite that was applied immediately after refrigeration showed the lowest shear bond strength, and the group stored at room temperature for three months showed the highest shear bond strength, and the difference between the two groups was significant. Conclusion: Ortho Connect can be used without worrying about bond strength even if it is used immediately after refrigeration, but Orthomite should be kept at room temperature sufficiently after refrigeration.