• Title/Summary/Keyword: conformal

Search Result 770, Processing Time 0.026 seconds

Clinical Study on Lobaplatin Combined with 5-Fu and Concurrent Radiotherapy in Treating Patients with Inoperable Esophageal Cancer

  • Jia, Xiao-Jing;Huang, Jing-Zi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6595-6597
    • /
    • 2015
  • Objective: To investigate short- and long-term treatment effects and side reactions of lobaplatin plus 5-Fu combined and concurrent radiotherapy in treating patients with inoperable middle-advanced stage esophageal cancer. Methods: Sixty patients with middle-advanced stage esophageal squamous cell cancer were retrospectively analyzed. All patients were administered lobaplatin (50 mg intravenously) for 2 h on day 1, and 5-Fu ($500mg/m^2$) injected intravenously from day 1 to 5 for 1 cycle, in an interval of 21 days for totally 4 cycles. At the same time, late-course accelerated hyperfractionated three-dimensional conformal radiotherapy was performed. Patients were firstly treated with conventional fractionated irradiation (1.8 Gy/d, 5 times/week, a total of 23 treatments, and DT41.4 Gy), and then treated with accelerated hyperfractionated irradiation (1.5 Gy, 2 times/d, a total of 27 Gy in 9 days, an entire course of 6-7 weeks, and DT 68.4Gy). Results: All patients completed treatment, including 10 complete response (CR), 41 partial response (PR), 7 stable disease (SD), and 2 progressive disease (PD). The total effective rate was 85.0% (51/60). Thirty-nine patients had an increased KPS score. One-, 2-, and 3-year survival rates were 85.3%, 57.5%, and 41.7%, respectively. The median survival time was 27 months. The adverse reactions included myelosuppression, which was mainly degree I and II. The occurrence rate of radiation esophagitis was 17.5%. No significant hepatic or renal toxicity was observed. Conclusion: Lobaplatin plus 5-Fu combined with concurrent radiotherapy is safe and effective in treating patients with middle-advanced stage esophageal cancer. However, this result warrants further evaluation by randomized clinical studies.

Evaluation of the Radiation Pneumonia Development Risk in Lung Cancer Cases

  • Yilmaz, Sercan;Adas, Yasemin Guzle;Hicsonmez, Ayse;Andrieu, Meltem Nalca;Akyurek, Serap;Gokce, Saban Cakir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7371-7375
    • /
    • 2014
  • Background: Concurrent chemo-radiotherapy is the recommended standard treatment modality for patients with locally advanced lung cancer. The purpose of three-dimensional conformal radiotherapy (3DCRT) is to minimize normal tissue damage while a high dose can be delivered to the tumor. The most common dose limiting side effect of thoracic RT is radiation pneumonia (RP). In this study we evaluated the relationship between dose-volume histogram parameters and radiation pneumonitis. This study targeted prediction of the possible development of RP and evaluation of the relationship between dose-volume histogram (DVH) parameters and RP in patients undergoing 3DCRT. Materials and Methods: DVHs of 41 lung cancer patients treated with 3DCRT were evaluated with respect to the development of grade ${\geq}2$ RP by excluding gross tumor volume (GTV) and planned target volume (PTV) from total (TL) and ipsilateral (IPSI) lung volume. Results: Were admitted statistically significant for p<0.05. Conclusions: The cut-off values for V5, V13, V20, V30, V45 and the mean dose of TL-GTV; and V13, V20,V30 and the mean dose of TL-PTV were statistically significant for the development of Grade ${\geq}2$ RP. No statistically significant results related to the development of Grade ${\geq}2$ RP were observed for the ipsilateral lung and the evaluation of PTV volume. A controlled and careful evaluation of the dose-volume histograms is important to assess Grade ${\geq}2$ RP development of the lung cancer patients treated with concurrent chemo-radiotherapy. In the light of the obtained data it can be said that RP development may be avoided by the proper analysis of the dose volume histograms and the application of optimal treatment plans.

Leadframe SiP with Conformal Shield

  • Kim, ByongJin;Sim, KiDong;Hong, SeoungJoon;Moon, DaeHo;Son, YongHo;Kang, DaeByoung;Khim, JinYoung;Yoon, JuHoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.31-34
    • /
    • 2016
  • System In Package (SiP) is getting popular and momentum for the recent wearable, IoT and connectivity application apart from mobile phone. This is driven by market demands of cost competitive, lighter and smaller/thinner and higher performance. As one of many semiconducting assembly products, Leadframe product has been widely used for low cost solution, light/ small and thin form factor. But It has not been applied for SiP although Leadframe product has many advantages in cost, size and reliability performance. SiP is mostly based on laminate substrate and technically difficult on Leadframe substrate because of a limitation in SMT performance. In this paper, Leadframe based SiP product has been evaluated about key technical challenges in SMT performance and electrical shield technology. Mostly Leadframe is considered not available to apply EMI shield because of tie-bar around package edge. In order to overcome two major challenges, connection bars were deployed properly for SMT pad to pad and additional back-side etching was implemented after molding process to achieve electrical isolation from outer shield coating. This product was confirmed assembly workability as well as reliability.

Fabrication of Low-cost and Flexible Potassium Ion Sensors based on Screen Printing and Their Electrochemical Characteristics (스크린 프린팅 기반 저가형의 플렉서블 칼륨 이온 센서 제조 및 이의 전기화학적 특성)

  • Son, Seon Gyu;Park, Hong Jun;Kim, Yeong Kyun;Cho, Hyeon-Sang;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.737-741
    • /
    • 2019
  • A low-cost and flexible potassium ion (K+) sensor was fabricated through a screen-printed process. Uniform and conformal coating of conductive inks was verified by scanning electron microscopy and optical microscopy measurements. The K+-sensors showed a high sensitivity, fast response time, and low detection limit. The sensitivity of K+-sensor was similar to that of both mechanically normal and bent states. The K+-sensor exhibited a good reproducibility with no hysteresis effect and excellent long term stability. In addition, the K+-sensor showed an excellent selectivity for K+ concentrations in the presence of other interfering cation ions. Successful measurements of K+ concentrations in sports drink samples were demonstrated by comparing K+ concentration values from K+-sensor to those of using a commercial K+-meter.

Beam-Like Ship Vibration Analysis in Consideration of Fluid (유체력을 고려한 보-유추 선체진동 해석)

  • Son, Choong-Yul
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.206-213
    • /
    • 1999
  • In the beam-like ship vibration analysis. three-dimensional correction factor(J-factor) can be calculated by considering the three-dimensional effect of the two-dimensional added mass. However, existing method is time-consuming with low accuracy in respect of global vibration analyses for vessels with large breadth. In this paper, to improve the demerit of the previous method, a new method of the beam-like ship vibration analysis is introduced In this method. the three-dimensional fluid added mass of surrounding water is calculated directly by solving the velocity potential problem using the Boundary Element Method (BEM). Then the three-dimensional added mass is evaluated as the lumped mass for each strip. Also, the beam-like ship vibration analysis for the structural beam model if performed with the lumped mass considered. It was verified that this new method is useful for the beam-like ship vibration analysis by comparing results obtained from both the existing method and the new method with experimental measurements for the open top container model.

  • PDF

Water Contact Angles of Graphene Transferred by Wet and Dry Transfer Methods (전사 방법에 따른 그래핀의 물 접촉각 변화)

  • Yoon, Min-Ah;Kim, Chan;Jung, Hyun-June;Kim, Jae-Hyun;Kim, Kwang-Seop
    • Tribology and Lubricants
    • /
    • v.34 no.2
    • /
    • pp.60-66
    • /
    • 2018
  • Graphene is a monolayer of carbon atoms (approximately 0.34 nm), arranged in a honeycomb network. It has been hailed as a next-generation flexible and transparent material because it has high electrical and thermal conductivities, excellent mechanical properties, as well as flexible and transparent properties. The wettability of graphene alters its adhesion or surface energy, and it is therefore an important parameter influencing its application in the fabrication of next-generation flexible and transparent electronics. Studies on the wettability of graphene are numerous and various opinions exist. However, almost all of these studies use the wet transfer method to transfer the graphene. In this study, therefore, we investigated the effect of wet and dry transfer methods on water contact angles of graphene on a substrate. The contact angles of substrates vary depending on the type of substrate. It was found that after graphene is transferred to the substrate, regardless of transfer method, the graphene/substrate contact angle increases to a value. The contact angle of graphene transferred using the dry transfer method is higher than the contact angle of graphene transferred using wet transfer methods. The wet transferred graphene is affected by the poly(methyl methacrylate) (PMMA) residue and the polar surface of substrate. The dry transferred graphene is influenced by the conformal contact between graphene and substrate.

The response of thrombosis in the portal vein or hepatic vein in hepatocellular carcinoma to radiation therapy

  • Bae, Bong Kyung;Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2016
  • Purpose: The purpose of current study is to evaluate the response of the patients with portal vein thrombosis (PVT) or hepatic vein thrombosis (HVT) in hepatocellular carcinoma (HCC) treated with three-dimensional conformal radiation therapy (3D-CRT). In addition, survival of patients and potential prognostic factors of the survival was evaluated. Materials and Methods: Forty-seven patients with PVT or HVT in HCC, referred to our department for radiotherapy, were retrospectively reviewed. For 3D-CRT plans, a gross tumor volume (GTV) was defined as a hypodense filling defect area in the portal vein (PV) or hepatic vein (HV). Survival of patients, and response to radiation therapy (RT) were analyzed. Potential prognostic factors for survival and response to RT were evaluated. Results: The median survival time of 47 patients was 8 months, with 1-year survival rate of 15% and response rate of 40%. Changes in Child-Pugh score, response to RT, Eastern cooperative oncology group performance status (ECOG PS), hepatitis C antibody (HCVAb) positivity, and additional post RT treatment were statistically significant prognostic factors for survival in univariate analysis (p = 0.000, p = 0.018, p = 0.000, p = 0.013, and p = 0.047, respectively). Of these factors, changes in Child-Pugh score, and response to RT were significant for patients' prognosis in multivariate analysis (p = 0.001 and p = 0.035, respectively). Conclusion: RT could constitute a reasonable treatment option for patients with PVT or HVT in HCC with acceptable toxicity. Changes in Child-Pugh score, and response to RT were statistically significant factors of survival of patients.

Gemcitabine-based Concurrent Chemoradiotherapy Versus Chemotherapy Alone in Patients with Locally Advanced Pancreatic Cancer

  • Wang, Bu-Hai;Cao, Wen-Miao;Yu, Jie;Wang, Xiao-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2129-2132
    • /
    • 2012
  • Objective: To explore improved treatment by retrospectively comparing survival time of gemcitabine-based concurrent chemoradiotherapy (GemRT) versus chemotherapy (Gem) alone in patients with locally advanced pancreatic cancer (LAPC). Methods: From January 2005 to June 2010, 56 patients with LAPC from Subei People's Hospital were treated either with Gem (n=21) or GemRT (n=35). Gem consisted of 4-6 cycles gemcitabine alone (1000 mg/m2 on Days 1, 8, 15, 28-day a cycle). GemRT consisted of 50.4Gy/28F radiotherapy with concurrent 2 cycles of gemcitabine (1000 $mg/m^2$ on days of radiation 1, 8, 15, 21-day a cycle). Radiation was delivered to the gross tumor volume plus 1-1.5 cm by use of a three-dimensional conformal technique. The follow-up time was calculated from the time of diagnosis to the date of death or last contact. Kaplan-Meier methodology wes used to evaluate survival. Results: Patient characteristics were not significantly different between treatment groups. The disease control rate and the objective response rate of GemRT versus Gem was 97.1% vs 71.4%, 74.3% vs 38.1%. The overall survival (OS) was significantly better for GemRT compared to Gem (median 13 months versus 8 months; 51.4% versus 14.3% at 1 year, respectively). Conclusion: Radiation therapy at 50.4Gy with 2 concurrent cycles of gemcitabine results in favorable rates of OS. Concurrent chemoradiotherapy should be the first choice for patients with LAPC.

Water vapor permeation properties of $Al_2O_3/TiO_2$ passivation layer on a poly (ether sulfon) substrate

  • Gwon, Tae-Seok;Mun, Yeon-Geon;Kim, Ung-Seon;Mun, Dae-Yong;Kim, Gyeong-Taek;Han, Dong-Seok;Sin, Sae-Yeong;Park, Jong-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.160-160
    • /
    • 2010
  • Organic electronic devices require a passivation layer to ensure sufficient lifetime. Specifically, flexible organic electronic devices need a barrier layer that transmits less than $10^{-6}\;g/m^2/day$ of water and $10^{-5}\;g/m^2/day$ of oxygen. To increase the lifetime of organic electronic device, therefore, it is indispensable to protect the organic materials from water and oxygen. Severe groups have reported on multi-layerd barriers consisting inorganic thin films deposited by plasma enhenced chemical deposition (PECVD) or sputtering. However, it is difficult to control the formation of granular-type morphology and microscopic pinholes in PECVD and sputtering. On the contrary, atomic layer deoposition (ALD) is free of pinhole, highly uniform, conformal films and show good step coverage. In this study, the passivation layer was deposited using single-process PEALD. The passivation layer, in our case, was a bilayer system consisting of $Al_2O_3$ films and a $TiO_2$ buffer layer on a poly (ether sulfon) (PES) substrate. Because the deposition temperature and plasma power have a significant effect on the properties of the passivation layer, the characteristics of the $Al_2O_3$ films were investigated in terms of density under different deposition temperatures and plasma powers. The effect of the $TiO_2$ buffer layer also was also addressed. In addition, the water vapor transmission rate (WVTR) and organic light-emitting diode (OLEDs) lifetime were measured after forming a bilayer composed of $Al_2O_3/TiO_2$ on a PES substrate.

  • PDF

A Study on the Conformity of the Goods under International Sale (국제물품매매에서 물품의 계약적합성에 관한 연구)

  • OH, Hyon-Sok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.66
    • /
    • pp.25-46
    • /
    • 2015
  • The purpose of this paper is to provide a legal implication about conformity of goods in the international commercial transactions. There are so many legal relationship after the formation of contract. The most of important thing among the obligations of seller is to provide conformal goods which are of quantity, quality and description required by the contract and which are contained or packaged in the manner required by the contract. If seller violate above duties, seller take the warranty liability. However, CISG describe the conformity of the goods instead of the warranty as follows. First, CISG Art.35(1) states standards for determining whether goods delivered by the seller conform to the contract and Art.35(2) describes standards relating to the goods' quality, function and packaging that, while not mandatory, are presumed to be a part of sales contracts. Article 35(2) is comprised of four subparts. Two of the subparts (article 35(2) (a) and article 35(2)(d)) apply to all contracts unless the parties have agreed otherwise. Second, CISG Art.36 and 38 deals with the time at which a lack of conformity in the goods must have arisen in order for the seller to be liable for it. If seller lack of conformity becomes apparent only after that time, seller is liable for a lack of conformity existing when risk passed to the buyer. Third, CISG Art.49 describe that a buyer who claims that delivered goods do not conform to the contract has an obligation to give the seller notice of the lack of conformity. The most of important things about CISG articles and precedents is that buyer is aware of the lack of conformity and notice it to seller. Failure to satisfy the notice requirements of article 39 eliminates a buyer's defence, based on a lack of conformity in delivered goods, to a seller's claim for payment of the price. Consequently, parties of contract had better agree to the notifying times about lack of conformity. Also, If seller fined the non-conformity, seller has to notify this circumstance to the buyer within short period or agreed time.

  • PDF