• 제목/요약/키워드: confocal laser scanning microscopy (CLSM)

검색결과 76건 처리시간 0.027초

Application of Autofluorescence for Confocal Microscopy to Aid in Archaeoparasitological Analyses

  • Morrow, Johnica Jo;Elowsky, Christian
    • Parasites, Hosts and Diseases
    • /
    • 제57권6호
    • /
    • pp.581-585
    • /
    • 2019
  • Confocal laser scanning microscopy (CLSM) was used to examine archaeoparasitological specimens from coprolites associated with La Cueva de los Muertos Chiquitos (CMC) located near present-day Durango, Mexico. The eggs for 4 different types of parasites recovered from CMC coprolites were imaged using CLSM to assist with identification efforts. While some of the parasite eggs recovered from CMC coprolites were readily identified using standard light microscopy (LM), CLSM provided useful data for more challenging identifications by highlighting subtle morphological features and enhancing visualization of parasite egg anatomy. While other advanced microscopy techniques, such as scanning electron microscopy (SEM), may also detect cryptic identifying characters, CLSM is less destructive to the specimens. Utilizing CLSM allows for subsequent examinations, such as molecular analyses, that cannot be performed following SEM sample preparation and imaging. Furthermore, CLSM detects intrinsic autofluorescence molecules, making improved identification independent of resource and time-intensive protocols. These aspects of CLSM make it an excellent method for assisting in taxonomic identification and for acquiring more detailed images of archaeoparasitological specimens.

Confocal Microscopy Measurement of the Fiber Orientation in Short Fiber Reinforced Plastics

  • Lee, Kwang Seok;Lee, Seok Won;Youn, Jae Ryoun;Kang, Tae Jin;Chung, Kwansoo
    • Fibers and Polymers
    • /
    • 제2권1호
    • /
    • pp.163-172
    • /
    • 2001
  • To determine three-dimensional fiber orientation states in injection-molded short fiber composites a CLSM (Confocal Laser Scanning Microscope) is used. Since the CLSM optically sections the composites, more than two cross-sections either on or below the surface of the composite can be obtained. Three dimensional fiber orientation states can be determined with geometric parameters of fibers on two parallel cross-sections. For experiment, carbon fiber reinforced polystyrene is examined by the CLSM. Geometric parameters of fibers are measured by image analysis. In order to compactly describe fiber orientation states, orientation tensors are used. Orientation tensors are determined at different positions of the prepared specimen. Three dimensional orientation states are obtained without the difficulty in determining the out-of-plane angles by utilizing images on two parallel planes acquired by the CLSM. Orientation states are different at different positions and show the shell-core structure along the thickness of the specimen.

  • PDF

Confocal laser scanning microscopy image를 이용한 UASB granule의 메탄 생성 능력 측정

  • 이유진;김효섭;안영희;박성훈
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.365-369
    • /
    • 2000
  • 반응기의 performance를 결정하는 중요한 요소는 methane 생성균의 활성을 측정하는 것이다. Methanogen의 활성을 측정하는 방법으로 SMA가 유일하게 사용되고 있다. 따라서 본 연구에서는 methanogen의 활성을 측정하는 다른 대안으로 CLSM image의 정량 분석 방법을 확립하였다. CLSM의 결과는 약 5시간 안에 얻을 수 있을 뿐만 아니라, 분자 생물학적인 기술을 많이 요하지 않는다. 또한, sludge내부의 상태와 methanogen의 분포정도를 사진으로 볼 수 있는 장점이 있다. 따라서 SMA와 함께 CLSM image 정량 분석은 UASB반응기의 start-up 동안의 methanogen의 활성을 측정하기 위한 유용한 방법으로 제안할 수 있다.

  • PDF

압입 표면형상의 구현과 체적계산법 (Indented Surface Configuration and its Volume Calculation)

  • 양재용;윤문철
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.708-713
    • /
    • 2012
  • The indented geometry for rockwell hardness indenter has been configured by using Confocal Laser Scanning Microscopy (CLSM). For this purpose, the CLSM can be well suited to construct the three-dimensional indented volume from the indented surface by rockwell hardness tester. Furthermore, the height data of HEI(height encoded image) by CLSM must be acquired at first and converted to indented surface later. And the indented surface patterns enable us to predict the indenter shape and volume. This volume can be used to study the rockwell hardness model as a volume parameter. As a result, the technique performed in this study by combining the CLSM with compensation technique is an excellent one to obtain the geometries of indented surfaces over a wide range of surface resolution in a micro scale. And it can be used for micro volume calculation.

공초점 레이저 주사 현미경을 이용한 단섬유 복합재료 사출 성형물 내의 섬유 배열 측정 및 수치모사 (Fiber Orientation in Injection-Molded Short Fiber Composites with a Confocal Laser Scanning Microscope and Numerical Simulation)

  • Lee, Kwang-Seok;Le, Seok-Won;Youn, Jae-Ryoun
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.201-204
    • /
    • 2001
  • A Confocal Laser Scanning Microscope (CLSM) is applied to determine three-dimensional fiber orientation states in injection-molded short fiber composites. Since the CLSM optically sections the composites, more than two planes either on or below the surface of composites can be obtained. Therefore, three dimensional fiber orientation states are determined without destruction. To predict the orientation states, velocity and temperature fields are calculated by using a hybrid FEM/FDM method. The change of orientation state during packing stage is also considered by employing a compressible Hele-Shaw model. The predicted orientation states show good agreement with measured ones. However, some differences are found at the end of cavity. They may result from other effects, which are not considered in the numerical analysis.

  • PDF

공초점 현미경을 이용한 마이크로믹서 내부의 3차원 이미지화 (3-D Imaging in a Chaotic Micromixer Using Confocal Laser Scanning Microscopy (CLSM))

  • 김현동;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.96-101
    • /
    • 2006
  • 3-D visualization using confocal laser scanning microscopy (CLSM) in a chaotic micromixer was performed as a reproduction experiment and the feasibility of 3-0 imaging technique in the microscale was confirmed. For diagonal micromixer (DM) and two types of staggered herringbone micromixers (SHM) designed by Whitesides et al., to verify the evolution of mixing, cross sectional images are reconstructed at the end of every cycle. In a DM, clockwise rotational flow motion generated by diagonal ridges placed on the floor of micromixer is observed and this motion makes the fluid commingle. On the contrary, there are two rotational flow structures in the SHM and the centers of rotation exchange their position each other every half cycle because of the V shape of ridges varying their orientation every half cycle. Local rotational flow and local extensional flow generated by the complicate ridge pattern make the flow be chaotic and accelerate the mixing of fluid. The dominant parameter that influences on the mixing characteristic of SHM is not the length of micromixer but the number of ridges under the same flow configurations.

  • PDF

Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구 (STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE)

  • 김지태;김성오;김종수
    • 대한소아치과학회지
    • /
    • 제33권1호
    • /
    • pp.1-12
    • /
    • 2006
  • 최근 새로 개발된 DIFOTI(Digital Imaging Fiber-Optic Transillumination) 시스템의 초기 법랑질 우식증 진단 능력을 평가하고 임상 적용의 가능성을 타진해 보고자 본 연구를 시행하였다. 임상 연구는 유치 탈락 시기에 근접한 학령기 아동 23명을 대상으로 DIFOTI 이미지 촬영을 시행하고 자연 탈락된 유치 20개를 수거하여 CLSM 촬영 결과를 바탕으로 민감도(sensitivity)와 특이도(specificity)를 산출하였으며 실험실 연구에서는 수거된 40개의 유치를 대상으로 Carbopol 인공 우식 용액으로 1, 2, 4 그리고 8일간 탈회시킨 후 각각 방사선 사진, DIFOTI 이미지 그리고 CLSM와 비교 분석하여 다음과 같은 결론을 얻었다. 1. 구내에서 촬영한 DIFOTI 이미지의 민감도는 0.61이었고, 특이도는 0.63이었다. 2. 실험실에서 인공 탈회시킨 유치의 협설면 초기 우식증에 대한 DIFOTI 이미지의 민감도는 0.71였고, 특이도는 0.75였다.

  • PDF

3차원 Confocal Imaging과 생체 영상 분석 (Three Dimensional Confocal Imaging and Biomedical Image Analysis)

  • 이임걸
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.257-261
    • /
    • 1995
  • Confocal laser scanning microscopy (CLSM)는 기존의 coherent or incoherent microscopic imaging 보다 횡축 방향 (lateral direction)으로 고해상도를 가지며, 층과 층 사이를 구분하는 광축 방향 (axial direction)의 optical sectioning에 의해 샘플의 3D 구조를 고해상도로 영상화함으로써 3D 구조 및 생체 기능 분석을 가능하게 해 준다. 본 논문에서는 CLSM에 의한 3D 영상화 원리와 촛점면 부근에서 얻어지는 광세기 분포, 얻어진 2D slice 영상의 시각화 및 응용에 대해 논의된다.

  • PDF

공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구 (Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope)

  • 임수희;김위한;이호;이춘영;박철우
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

크레이터 마모의 체적계산 및 분석법 (Crater Wear Volume Calculation and Analysis)

  • 정진석;조희근;윤문철
    • 한국생산제조학회지
    • /
    • 제18권3호
    • /
    • pp.248-254
    • /
    • 2009
  • The worn crater wear geometry of coated tools after machining has been configured by using Confocal Laser Scanning Microscopy(CLSM) and the Wavelet-based filtering technique. The CLSM can be well suited to construct the three-dimensional crater wear on the rake surfaces of coated tips. However, The raw heightness data of HEI(height encoded image) acquired by CLSM must be filtered due to the electronic and imaging noise occurring in constructing the crater image. So the Wavelet-based filtering algorithm is necessary to denoise the shape features in a micro scales so as to realize accurate crater wear topography analysis. The crater wear patterns filtered enable us to predict the crater wear shape in order to study the tool wear evolution. The study shows that the technique by combining the CLSM and Wavelet-based filtering is an excellent one to obtain the geometries of worn tool rake surfaces over a wide range of surface resolution in a micro scale.

  • PDF