• 제목/요약/키워드: confinement steel ratio

검색결과 163건 처리시간 0.021초

휨전단 거동을 보이는 원형 RC교각의 내진성능평가 (Seismic Performance of Flexural-Shear Circular Reinforced Concrete Bridge Piers)

  • 송호진;정영수;김용곤;김훈;김대호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.823-828
    • /
    • 2002
  • Lap splice in plastic hinge region of RC bridge piers is inevitable because of the constructional joint between footing and column. RC circular columns with lap-splice in plastic hinge region are widely used in Korean highway bridges. It is, however, believed that there we not many experimental research works for nonlinear behavior of these columns subjected to earthquake motions. This study has been peformed to verify the effect of lap splice and confinement steel ratio for the seismic behaviour of reinforced concrete bridge piers. Quasi-static test have been done to investigate the physical seismic performance of RC bridge piers, such as displacement ductility.

  • PDF

역량스펙트럼 및 에너지분석을 이용한 RC교각의 내진성능평가에 관한 연구 (Seismic Performance Evaluation of RC Bridge Piers using Capacity Spectrum and Energy Analysis)

  • 정영수;박종협
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.361-367
    • /
    • 2001
  • This research aims at evaluating the seismic performance of the R/C bridge piers, which were seismically designed in accordance with the seismic provision of limited ductile behavior of Eurocode 8. Pseudo dynamic test for six(6) circular RC bridge piers has been carried out so at to investigate their seismic performance subjected to experted artificial earthquake motions. The objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete bridge piers. Important test parameters are confinement steel ratio, input ground motion, etc. The seismic behavior of circular concrete piers under artificial ground motions has been evaluated through displacement ductility, energy analysis, capacity spectrum. It can be concluded that RC bridge piers designed in the seismic code of limited ductile behavior of Eurocode 8 have been determined to show good seismic performance even under expected artificial earthquakes in moderate seismicity region.

  • PDF

비선형 해석프로그램을 이용한 RC교각의 진동대 시험 분석 (The analysis of RC bridge piers on shaking table test by using Nonlinear program)

  • 양동욱;박용권;이연훈;정영수;이대형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.67-68
    • /
    • 2009
  • 본 연구는 기존의 실험 방법과 다른 근단층 지반 운동하에서의 진동대 시험을 통해 심부구속 철근비에 따른 내진성능 평가를 비교 분석하였다. 또한 비선형 해석프로그램 SARCF(Seismic Analysis of Reinforced Concrete Frames)로 교각의 손상에 따른 고유진동수의 변화를 해석을 통한 FFT 값과 시험에 의한 FFT 값을 비교 분석하여 진동대 시험에 대한 평가를 하였다.

  • PDF

Pseudo-dynamic실험에 의한 원형충진 RC 교각의 내진거동 (Seismic Performance of Circular Reinforced Concrete Bridge Piera By Pseudo-Dynamic Test)

  • 조창백;소진호;빅종협;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.464-469
    • /
    • 2000
  • Since the occurrence of 1995 Kobe earthquake, there have been much concern about seismic design for various infrastructures, inclusive of bridge structures. This research aims at evaluating the seismic performance of the existing R/C bridge piers, which were nonseismically or seismically designed in accordance with the provision of Korea Highway Design Specification. Further experimental investigations have been doing to figure out the retrofitting effects of nonseismic R/C bridge piers confined with glass fiber at the plastic hinge zone. Pseudo-dynamic tests have been carried out in nine scaled R/C column specimens to investigate their hysteretic behavior under earthquake loading. Test parameters are axial load, input ground motion confinement steel ratio, glass fiber and etc.

  • PDF

철근콘크리트 교각 심부구속철근량의 비교연구 (comparative Study on confinement Steel Amount of RC Column Bent)

  • 이재훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.239-246
    • /
    • 1999
  • recently there have been many destructive seismic events in Kobe Japan in 1995 and in Northridge California USA in 1994. etc. The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. Comparing the earthquake magnitude in Korea with those in the west coast of the USA it may be said that the current seismic design requirements of the Korean Bridge Design Standard Specifications provides too conservation design results especially for transverse reinforcement details and amount in reinforced concrete columns. This fact usually makes construction problems in concrete casting due to transverse reinforcement congestion. And the effective stiffness Ieff depends on the axial load P(Ag{{{{ {f }_{ck } }}) and the longitudinal reinforcement ratio Ast/Ag and it is conservative to use the effective stiffness Ieff than the gross section moment Ig. Seismic design for transverse reinforcement content of concrete column is considered of extreme-fiber compression strain R-factor axial load and stiffness etc.

  • PDF

탄소섬유쉬트로 구속된 콘크리트충전 원형강관기둥의 단조압축실험 (Experimental Study on Concrete Steel Circular Tubes Confined by Carbon Fiber Sheet under Axial Compression Loads)

  • 박재우;홍영균;홍기섭;최성모
    • 한국지진공학회논문집
    • /
    • 제13권5호
    • /
    • pp.61-71
    • /
    • 2009
  • 본 연구에서는 기존 원형 CFT기둥 실험체와 탄소섬유쉬트로 추가구속된 원형 CFT기둥 실험체의 단조압축거동 및 압축내력평가에 관한 실험을 수행하였다. 실험변수는 탄소섬유쉬트 보강겹수와 직경-두께비이며, 실험변수에 따라 총 10개의 실험체를 제작하여 단조압축실험을 수행하였다. 실험을 통하여 기존 CFT 실험체와 탄소섬유쉬트로 구속된 CFT 실험체의 파괴거동, 하중-축변위 곡선, 최대내력, 변형성능을 비교한다. 끝으로 탄소섬유쉬트의 추가구속을 통해 기둥의 국부좌굴을 지연시켰으며 구속효과로 인해 내력은 상승하는 것으로 나타났다.

Effect of spiral spacing on axial compressive behavior of square reinforced concrete filled steel tube (RCFST) columns

  • Qiao, Qiyun;Zhang, Wenwen;Mou, Ben;Cao, Wanlin
    • Steel and Composite Structures
    • /
    • 제31권6호
    • /
    • pp.559-573
    • /
    • 2019
  • Spiral spacing effect on axial compressive behavior of reinforced concrete filled steel tube (RCFST) stub column is experimentally investigated in this paper. A total of twenty specimens including sixteen square RCFST columns and four benchmarked conventional square concrete filled steel tube (CFST) columns are fabricated and tested. Test variables include spiral spacing (spiral ratio) and concrete strength. The failure modes, load versus displacement curves, compressive rigidity, axial compressive strength, and ductility of the specimens are obtained and analyzed. Especially, the effect of spiral spacing on axial compressive strength and ductility is investigated and discussed in detail. Test results show that heavily arranged spirals considerably increase the ultimate compressive strength but lightly arranged spirals have no obvious effect on the ultimate strength. In practical design, the effect of spirals on RCFST column strength should be considered only when spirals are heavily arranged. Spiral spacing has a considerable effect on increasing the post-peak ductility of RCFST columns. Decreasing of the spiral spacing considerably increases the post-peak ductility of the RCFSTs. When the concrete strength increases, ultimate strength increases but the ductility decreases, due to the brittleness of the higher strength concrete. Arranging spirals, even with a rather small amount of spirals, is an economical and easy solution for improving the ductility of RCFST columns with high-strength concrete. Ultimate compressive strengths of the columns are calculated according to the codes EC4 (2004), GB 50936 (2014), AIJ (2008), and ACI 318 (2014). The ultimate strength of RCFST stub columns can be most precisely evaluated using standard GB 50936 (2014) considering the effect of spiral confinement on core concrete.

Response of lap splice of reinforcing bars confined by FRP wrapping: modeling approach

  • Thai, Dam Xuan;Pimanmas, Amorn
    • Structural Engineering and Mechanics
    • /
    • 제37권1호
    • /
    • pp.95-110
    • /
    • 2011
  • This paper presents a tri-uniform bond stress model for predicting the lap splice strength of reinforcing bar at the critical bond splitting failure. The proposed bond distribution model consists of three zones, namely, splitting zone, post-splitting zone and yielding zone. In each zone, the bond stress is assumed to be constant. The models for bond strength in each zone are adopted from previous studies. Combining the equilibrium, strain-slip relation and the bond strength model in each zone, the steel stress-slip model can be derived, which can be used in the nonlinear frame analysis of the column. The proposed model is applied to derive explicit equations for predicting the strength of the lap splice strengthened by fiber reinforced polymer (FRP) in both elastic and post-yield ranges. For design purpose, a procedure to calculate the required FRP thickness and the number of FRP sheets is also presented. A parametric investigation was conducted to study the relation between lap splice strength and lap splice length, number and thickness of FRP sheets and the ratio of concrete cover to bar diameter. The study shows that the lap splice strength can be enhanced by increasing one of these parameters: lap splice length, number or thickness of FRP sheets and concrete cover to bar diameter ratio. Verification of the model has been conducted using experimental data available in literature.

복합폴리우레아를 도포한 콘크리트 구조물의 구조성능 개선에 관한 실험적 연구 (An Experimental Study on the Improvement of Structural Performance for Concrete Structure Spraying Composite Polyurea)

  • 조동호;김진봉;김태완;은희창
    • 대한건축학회논문집:구조계
    • /
    • 제35권1호
    • /
    • pp.21-28
    • /
    • 2019
  • This study investigates the applicability of composite polyurea to contain fiber reinforcement like fiber glass, steel fiber and carbon nanotube. Polyurea as elastomer is an excellent water-proofing material with many mechanical characteristics such as high tensile strength, ductility, high rate of expansion and contraction, and so on. The reinforcing fibers can be utilized for improving the load-carrying capacity of concrete structures. The polyurea plays a role to improve the ductility and toughness. Composite polyurea takes the mechanical advantages of the fibers and the polyurea. The test variables include the type of reinforcing fiber, its spraying thickness, and its weight ratio contained in the composite polyurea. It is observed that the load-carrying capacity, and the ductility and toughness are improved with the increase in the spraying thickness and the weight ratio contained in the composite polyurea. It is expected that the composite polyurea can be widely utilized in enhancing the structural and seismic performance.

와이어로프와 T 강판으로 비부착 보강된 철근콘크리트 기둥의 중심 축하중 거동 (Axial Behavior of Reinforced Concrete Columns Externally Strengthened with Unbonded Wire Rope and T-Shaped Steel Plate)

  • 양근혁;심재일;변항용
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.221-229
    • /
    • 2008
  • 와이어로프와 T형 강판을 이용한 개선된 비부착형 기둥보강 공법이 개발되었다. 제시된 절차에 따라 보강된 기둥 8개와 동일한 조건의 무보강 기둥 1개가 중심 축하중 하에서 실험되었다. 주요 변수는 와이어로프 체적비와 T 강판의 플랜지 폭 및 배치 형상이다. 실험된 기둥의 축하중 내력과 연성비는 각각 ACI 318-05의 예측값과 Chung et al.에 의해 수행된 일반 띠기둥의 실험 결과와 비교되었다. 게다가 와이어로프와 T 강판으로 구속된 콘크리트의 응력-변형률 관계를 평가하기 위한 모델이 제시되었다. 실험 결과로부터 기둥의 축하중 내력과 연성은 와이어로프의 체적비와 T 강판의 플랜지 폭의 증가와 함께 증가하였다. 특히 동일 횡보강근 지수에서 와이어로프 체적비가 0.0039 이상일 때 보강된 기둥의 연성비는 띠철근 기둥에 비해 현저히 높았다. 개발된 보강기술에 의해 구속된 콘크리트의 응력-변형률 관계 모델이 제시되었다. 예측된 응력-변형률 관계는 실험 결과와 잘 일치하였다.