• Title/Summary/Keyword: cones

Search Result 295, Processing Time 0.026 seconds

INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구)

  • Choi Jin-Uk;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop;Jeong Hee-Chan;Eom Tae-Gwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.229-242
    • /
    • 2006
  • Statement of problem: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. Purpose: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. Material and method: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy Results and conclusion: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P<.05). The increasing rate of compressive force by coating in external butt joint was gloater than those in internal cones (P<.05). 2. Coated screw showed the significant additional rotation compared to non-coated screw in all implant systems (P<.05). There were no significant differences in the increasing rate of rotation among implant systems (P>.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P<.05). 4. Coated screw showed insignificant variations in the compressive forces during 10 consecutive trials(P>.05) 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However surface wearing and irregular titanium fragments were found in non-coated screw.

Molt-staging and Setal Morphology of Metapenaeopsis dalei (Decapoda: Penaeidae) (산모양깔깔새우 (Metapenaeopsis dalei)의 탈피단계와 강모의 형태적 특징)

  • CHOI Jung Haw;HONG Sung Yun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.1
    • /
    • pp.38-42
    • /
    • 2001
  • Molt-staging of Metapenaeopsis dalei was determined by microscopic observation on their setal development of dissected uropods, Five major stages (Stage A, B, C, D and E) were defined by the morphology of setal development. Premolt stage (Stage D) can be divided into 4 distinctive substages ($D_1{\sim}D_4$) according to the premolting processes. The setal cones were formed at Stage B under the old cuticle, and the setal shafts were visible at the end of such Stage $D_1'$. The casting process of the old cuticle lasted less than 1 min. The molt stages in M. dalei thus are generally similar to those of other shrimp species.

  • PDF

First Record of the Western Conifer Seed Bug, Leptoglossus occidentalis Heidemann (Heteroptera: Coreidae) in Korea (소나무허리노린재(국명신칭), Leptoglossus occidentalis Heidemann (Heteroptera: Coreidae)의 한국 내 신 분포 기록)

  • Yoon, Chun-Sik;Kim, Hyoung-Gon;Park, Jong-Dae;Choi, Won-Young;Choi, Hyeok-Jae;Cheong, Seon-Woo
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.1009-1013
    • /
    • 2012
  • Leptoglossus occidentalis Heidemann, 1910 was newly recorded in Korea as a invasive species at Gyeongsangnam-do, Korea in 2010 and 2011. Leptoglossus Guerin-Meneville, 1831 is also newly recorded Coreid genus in Korea. The diagnostic shape is expanded leaf-like hind tibiae. The origin of this species is North America and it has been rapidly propagated around the world as a pest. This bug recognized as a pest on almost of Pinaceae plants and they suck on developing cones, so the monitoring on the present invasion of this species in Korea is urgent. It was presumed that the invasion of Leptoglossus occidentalis into Korea was before 2010 with present study.

Full ice-cream cone model for halo coronal mass ejections

  • Na, Hyeonock;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.65.3-66
    • /
    • 2015
  • The determination of three dimensional parameters (e.g., radial speed, angular width, source location) of Coronal Mass Ejections (CMEs) is very important for space weather forecast. To estimate these parameters, several cone models based on a flat cone or a shallow ice-cream cone with spherical front have been suggested. In this study, we investigate which cone model is proper for halo CME morphology using 33 CMEs which are identified as halo CMEs by one spacecraft (SOHO or STEREO-A or B) and as limb CMEs by the other ones. From geometrical parameters of these CMEs such as their front curvature, we find that near full ice-cream cone CMEs (28 events) are dominant over shallow ice-cream cone CMEs (5 events). So we develop a new full ice-cream cone model by assuming that a full ice-cream cone consists of many flat cones with different heights and angular widths. This model is carried out by the following steps: (1) construct a cone for given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, (4) minimize the difference between the estimated projection points with the observed ones. We apply this model to several halo CMEs and compare the results with those from other methods such as a Graduated Cylindrical Shell model and a geometrical triangulation method.

  • PDF

Endodontic management of a mandibular second molar with radix entomolaris: a case report

  • Hannah, Rosaline;Kandaswamy, Deivanayagam;Jayaprakash, Nachimuthu
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.132-136
    • /
    • 2014
  • The presence of radix entomolaris (RE) in a mandibular first molar is a common occurrence in certain ethnic groups, but the presence of RE in a mandibular second molar is a rare occurrence. In the present case, RE was identified from preoperative radiographs and confirmed using cone-beam computed tomography (CBCT). The access cavity was modified to locate the RE. Cleaning and shaping were performed with nickel-titanium rotary instruments. Obturation was completed with gutta-percha cones using AH Plus (Dentsply Detrey GmbH) as sealer. From the CBCT axial images, the RE was determined to have a Type III curvature by the De Moor classification, Type B separate RE by the Carlsen and Alexandersen classification, and radiographically, a Type i image by the Wang classification. The presence of RE in the mandibular second molar makes it essential to anticipate and treat the distolingual root canal. This case report highlights the usefulness of CBCT for assessing RE in the mandibular second molar, which can help the clinician in making a confirmatory diagnosis and assessing the morphology of the root canal.

The reduction methods of operator's radiation dose for portable dental X-ray machines

  • Cho, Jeong-Yeon;Han, Won-Jeong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.160-164
    • /
    • 2012
  • Objectives: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. Conclusions: When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

Mini Neutron Monitors at Concordia Research Station, Central Antarctica

  • Poluianov, Stepan;Usoskin, Ilya;Mishev, Alexander;Moraal, Harm;Kruger, Helena;Casasanta, Giampietro;Traversi, Rita;Udisti, Roberto
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.281-287
    • /
    • 2015
  • Two mini neutron monitors are installed at Concordia research station (Dome C, Central Antarctica, $75^{\circ}06^{\prime}S$, $123^{\circ}23^{\prime}E$, 3,233 m.a.s.l.). The site has unique properties ideal for cosmic ray measurements, especially for the detection of solar energetic particles: very low cutoff rigidity < 0.01 GV, high elevation and poleward asymptotic acceptance cones pointing to geographical latitudes > $75^{\circ}S$. The instruments consist of a standard neutron monitor and a "bare" (lead-free) neutron monitor. The instrument operation started in mid-January 2015. The barometric correction coefficients were computed for the period from 1 February to 31 July 2015. Several interesting events, including two notable Forbush decreases on 17 March 2015 and 22 June 2015, and a solar particle event of 29 October 2015 were registered. The data sets are available at cosmicrays.oulu.fi and nmdb.eu.

STREAMING CIRCUMNUCLEAR GAS OF THE SEYFERT 2 GALAXY NGC 5728

  • Son, Dong-Hoon;Hyung, Siek;Lee, Seong-Jae;Ferruit, Pierre
    • Journal of The Korean Astronomical Society
    • /
    • v.42 no.5
    • /
    • pp.125-134
    • /
    • 2009
  • We investigated the circumnuclear region of the Seyfert 2 galaxy NGC 5728, using the CFHT 3.6 m OASIS $[S_{II}]$, $[O_{III}]$ & $H\beta$ spectral images complemented with the IUE spectra. The physical condition of the circumnuclear zone has been derived: the gas density (indicated by $[S_{II}]$6716/31 ratio) around the C core is generally similar to that around the NW core, i.e., $\sim500cm^{-3}$. However, there appears to be evidence of a higher density shell in front of the NW core, $\sim10^4cm^{-3}$ at -250 km $s^-1$. The IUE $Si_{III}$]1892/$C_{III}$]1909 ratio implies a possible presence of a broad emission region of gas densities of $\sim10^{10}cm^{-3}$. The SE cone and surrounding area show several prominent features, while the NW cone does not show any particular structure: we identified three prominent blobs in the SE cone and one possible candidate in the NW cone. The outflow activities exist within the relatively large conic opening angle. We discussed the possibility of inflow or outflow activities of blobs found in the circumnuclear region of NGC 5728. The gas around two cores, two cones, and several blobs, is likely to be excited by the AGN hot source(s).

POINT SPREAD FUNCTION OF THE SOFT X-RAY TELESCOPE ABOARD YOHKOH

  • SHIN JUNHO;SAKURAI TAKASHI
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.spc1
    • /
    • pp.117-124
    • /
    • 2003
  • Pre-launch calibration data have been analyzed for evaluating the point spread function (PSF) of Yohkoh Soft X-ray Telescope (SXT). Especially, it is found crucial that the effect of undersampling should be treated properly. The best fit solution of the SXT PSF, which is modeled by an elliptical Moffat function, has been derived by the comparison with the ground experiment data. In order to examine the off-axis variation of the SXT PSF, we need to define in advance the location of the optical axis on the CCD. According to the previous studies, the off-axis variation of effective area (the vignetting function) may be approximated either by two non-concentric cones or by a cone with some flat distortions. There have been, however, no fully approved representations for the SXT vignetting effect. The effect of the shift of the optical axis from the geometrical center of the telescope is investigated by numerical simulation. It is revealed from our study that the full width at half maximum (FWHM) of the SXT PSF stays nearly constant within an error bound over the central area of the CCD where the solar disk is located.

Electron Dosimetry of Shaped Fields on Mevatron KD 67-7467 (Mevatron KD 67-7467의 변형조사면에 대한 전자선 선량측정)

  • U Hong;Samuel Ryu;H. D. Kang
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.109-122
    • /
    • 1990
  • A method of making inserts for shaped fields in electron beam therapy on the Mevatron KD 67-7467 Linear Acclerator is introduced. The inserts are made from an alloy called Lipowitz metal. These are designed to fit the inside of the standard Siemens cones. Studies have shown that this method does not adversely affect field flatness. However, if the ratio of shaped field to open field is greater than about 70%, the output dose is significantly changed by the inserts. Because the cone ratios for the fields do not follow the open cone ratio curves on the Mevatron KD 67-7467, we separated the cone ratio suggested by Biggs into two parts, the insert ratio and the cone factor. The dosimetry for these shaped beams has been investigated extensively.

  • PDF