• Title/Summary/Keyword: conductivity meter

Search Result 97, Processing Time 0.024 seconds

Analysis of Conductivity Gas by using Automotive Dynamo-Meter (차량용 Dynamo-Meter를 이용한 도전성가스 분석연구)

  • 전영갑;서길수;노형우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.112-118
    • /
    • 2001
  • In this study the leakage current measurement method based on a porous ceramic is applied to check the conductive substance caused by the ionized particles. By using engine and chassis dynamometer and an experiment vehicle, in which the hydrocarbon sensor (HC sensor) was exposed to the exhaust gas to create the electrical signal, the HC sensor in the exhaust line checked the conductive ions in emission gas. Generally the output electrical signal of HC sensor is followed with amount of hydrocarbon in the experiments in cold start and operation. By combining the electrical signal, a measure of conductivity of exhaust gas with hydrocarbon can be provided by OBD (On Board Diagnosis) II and EMS (Engine Management System).

  • PDF

An Experimental Study on the Thermal Performance Measurement of Large Diameter Borehole Heat Exchanger(LD-BHE) for Tripe-U Pipes Spacer Apply (3중관용 스페이서를 적용한 대구경 지중열교환기의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Jong-Woo;Lim, Kyoung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.581-586
    • /
    • 2009
  • Knowledge of ground thermal properties is most important for the proper design of large scale BHE(borehole heat exchanger) systems. The type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for insitu determination of design data for large diameter BHE for triple-U spacer apply. The main purpose has been to determine insitu values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a circulation pump, a inline heater, temperature sensors, flow meter, power analysis meter and a data logger for recording the temperature, fluid flow data. A constant heat power is injected into the borehole through the tripl-U pipes system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance of large diameter BHE for spacer apply.

  • PDF

The Development of Portable Body Fat Meter (휴대용 체지방계의 개발)

  • Park, Jong-Chan;Lim, Eung-Choon;Park, Su-Hong;Han, Un-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.34-37
    • /
    • 2003
  • The purpose of this paper is the development of portable body fat meter. Bioelectrical impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat mass is far greater than that of the fat. Finally measurement of percent body fat was made possible using a developed impedance measuring device which measure impedance between the thumb and ring finger.

  • PDF

Development of Automatic System for Diagnosis of Mastitis in Dairy Cattle (유방염 자동진단시스템 개발)

  • 김명순;김용준
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.242-246
    • /
    • 1998
  • These studies were Performed to provide some basic informations for developing an automatic system in dairy farming in order that the farmers may easily and automatically detect the mastitis. Electrical conductivity of each milk sample was measured by micro-ohm meter and also the number of somatic cell was detected by somecounter. The major microorganisms causing mastitis were also investigated. The rate of infected cattle with mastitis was 33.0% among 2,540 dairy cattle and the rate of infected quarters with mastitis was 13.9 % among 9.660 quarters. When the number of somatic cell was under lost electrical conductivity of the milk was 0.073, whereas number of somatic cell was over $3{\times}10^{6}$, electrical conductivity was increased by 0.167. When electrical conductivity of milk was over 0.073, the cattle was diagnosised as mastitis. The major micmorganisms of mastitis were Staphylococcus spp. (55-60%) and Streptococcus spp. (15-20%).

  • PDF

An Experimental Study on the Measurement of Electrical Conductivity of Cementitious Composites According to the Type of Steel Fiber (강섬유 종류에 따른 시멘트 복합체의 전기전도도 측정에 대한 실험적 연구)

  • Lee, Yae-Chan;Kim, Gyu-Yong;Nam, Jeong-Soo;Lee, Sang-Kyu;Shu, Dong-Kyun;Eu, Ha-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.191-192
    • /
    • 2020
  • The purpose of this study is to measure the electrical conductivity of cementitious composites as an early step to obtain shielding performance by mixing various type of steel fiber into cementitious composites, the main building material of protection facility, to shield electromagnetic pulse (EMP) damage. Fiber such as conductors as amorphous metallic fiber, hooked steel fiber, and smooth steel fiber are mixed into cementitious composites to give electrical conductivity and measure the impedance of concrete using LCR meter. By doing this, the electrical conductivity of each type of steel fiber reinforced cementitious composites (FRCC) is compared.

  • PDF

Stability Evaluation on Measuring Water-soluble Chloride Anions from Iron Artifacts (철제유물의 수용성 염소이온 측정방법에 대한 안정성 평가)

  • Lee, Jae-Sung;Park, Hyung-Ho;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.397-406
    • /
    • 2010
  • The most ideal method to measure the water-soluble $Cl^-$ ion eluted from iron artifacts is conducting the analysis on desalting solution by Ion Chromatography. But most institutes related to cultural heritages use Cl meter by reason of lack of budget and experts. This study evaluated reliability and stability between Cl meter and Ion Chromatography by doing cross-validation with results from two methods to detect $Cl^-$ ion of desalting solution. From D.I water, extremely small quantities of $Cl^-$ ion was detected by the influence of remaining water-soluble $Cl^-$ ion at the electrode of Cl meter and water-soluble $Cl^-$ which remains in Sodium sesquicarbonate, components of reagent was detected as well. The first desalting solution had the most $Cl^-$ ions, $Cl^-$ ion slightly decreased from the second to the fourth desalting solution and tend to decrease again at the stage of dealkalified in D.I water. Each Cl meter has the standard deviation according to the measured numbers and the higher concentration of $Cl^-$ ion the desalting solution has, the wider the deviation is. But when the concentration of $Cl^-$ ion is low, it was stable to use Cl meter to detect the concentration of $Cl^-$ ion from iron artifacts because there is the small deviation, It is thought that conductivity meter method is not suitable for measuring $Cl^-$ ion, because the electrical conductivity of alkaline solution is too high to measure $Cl^-$ ion.

Preparation and Characteristics of Heat-releasing Sheet Containing AlN(alunimum nitride) Powder (AlN 분말을 이용한 방열 Sheet의 제조와 그 특성)

  • Kim, Sang-Mun;Lee, Seok-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.431-434
    • /
    • 2012
  • In this paper, heat-releasing sheets made of AlN powder and acryl binder as thermoset were prepared using tape casting method. The crystal structure and morphology, the thermal properties as nonvolatile solid content and thermal conductivity, and the surface resistance of heat-releasing sheet were measured by using X-ray diffractometer, field emission-scanning electron microscopy, thermo gravimetric analyzer and laser flash instrument, and surface resistance meter. It was proved that thermal conductivity is greatly affected by the content of binder in heat-releasing sheet. Superior thermal conductivity above 3.5 W/mK and suface resistance were obtained at heat-releasing sheet with above 90% of AlN powder.

Building Materials Thermal Conductivity Measurement and Correlation with Heat Flow Meter, Laser Flash Analysis and C-Therm TCi (HFM, LFA와 TCi를 이용한 건축 재료의 열전도율 측정과 상관관계 분석)

  • Cha, Jung-Hoon;Seo, Jung-Ki;Su-Min, Kim
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.92-97
    • /
    • 2011
  • Nowdays the most critical problem is global warming and the most important reason is the high emition of carbondioxide. 23% of the use of carbondioxide is used in building and decreasing the use of it is very important. One of the biggest factor that can decrease the use of energy is developing the heat conducting ratio of the materials we use in building. Heat conducting ratio is the important factor in the use of reducing energy comsumation. In this research, there are methods about how to measure the heat conducting ratio, and the existing the representing measuring method which is Heat Flow Meter HFM 436, Laser Flash Analysis and find out about the TCi of the new method C-Therm and compare the results.

  • PDF

Volume Resistivity, Specific Heat and Thermal Conductivity Measurement of Semiconducting Materials for 154[kV] (154[kV]용 반도전층 재료의 최적저항, 비열 및 열전도 측정)

  • Lee, Kvoung-Yong;Yang, Jong-Seok;Choi, Yong-Sung;Park, Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.477-482
    • /
    • 2005
  • We have investigated volume resistivity and thermal properties showed by changing the content of carbon black which is the component parts of semiconducting shield in underground power transmission cable. Specimens were made of sheet form with the nine of specimens for measurement. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the preheated oven of both 25$\pm$1[$^{\circ}C$] and 90$\pm$1[$^{\circ}C$]. And specific heat (Cp) and thermal conductivity were measured by Nano Flash Diffusivity and DSC (Differential Scanning Calorimetry). The measurement temperature ranges of specific heat using the BSC was from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity using Nano Flash Diffusivity were both 25[$^{\circ}C$] and 55[$^{\circ}C$]. Volume resistivity was high according to an increment of the content of carbon black from these experimental results. And specific heat was decreased, while thermal conductivity was increased by an increment of the content of carbon black. And both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

A Study on Thermal Conductivity Characteristics of Nanofluids (나노유체 열전도도 특성 연구)

  • Hwang, Yu-Jin;Park, Jae-Hong;Kim, Hong-Suk;Lee, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.162-167
    • /
    • 2006
  • Nanofluid is a kind of new engineering material consisting of nanoparticles dispersed in base fluid. Nanofluids could have various applications such as magnetic fluids, heat exchanger working fluids, lubricants, drug delivery and so on in present study, various nanoparticles, such as MWCNT (Multi-walled Carbon Nanotube), fullerene, copper oxide, and silicon dioxide are used to produce nanofluids. As base fluids, DI-water, ethylene glycol, oil, and silicon oil are used. To investigate the thermo-physical properties of nanofluids, thermal conductivity and kinematic viscosity are measured. Stability estimation of nanofluid is conducted with UV-vis spectrophoto-meter. In this study, the high pressure homogenizer is the most effective method to produce nanofluid with the prepared nanoparticle and base fluid. Excellently stable nanofluids are produced with the magnetron sputtering system. Thermal conductivity of nanofluid increases with increasing particle volume fraction except water-based fullerene nanofluid which has lower thermal conductivity than base fluid due to its lower thermal conductivity, 0.4 W/mK. The experimental results can't be predicted by Jang and Choi model.

  • PDF