• Title/Summary/Keyword: conduction ratio

Search Result 270, Processing Time 0.025 seconds

Prognostic Value of Inferior Shift of P wave Axis after Catheter Ablation for Longstanding Persistent Atrial Fibrillation based on Dallas Lesion Set Including Anterior Line

  • Shin, Dong Geum;Kim, Tae-Hoon;Jeong, Hyunmin;Kim, Alexander;Uhm, Jae-Sun;Joung, Boyoung;Lee, Moon-Hyoung;Hwang, Chun;Pak, Hui-Nam
    • International Journal of Arrhythmia
    • /
    • 제18권2호
    • /
    • pp.66-76
    • /
    • 2017
  • Background and Objectives: Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods: We studied 304 L-PeAF patients (77% male, $60{\pm}10yrs$), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results: 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (${\ss}=10.4$, 95% confidence interval [CI] 2.79-17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97-0.99, p=0.001), during $45.6{\pm}16.7$ months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion: An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.

Analysis of Integration Factor Effect in Dynamic-Structure-Fluid-Heat Coupled Time Transient Staggered Integration Scheme for Morton Effect Analysis (모튼이펙트 해석을 위한 동역학-구조-유체-열전달 시간과도응답 연성해석 시차적분법에서 시상수 효과 분석)

  • Suh, Junho;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.77-86
    • /
    • 2019
  • The present study focuses on the effect of staggered integration factor (SIF) on Morton effect simulation results. The Morton effect is a synchronous rotordynamic instability problem caused by the temperature differential across the journal in fluid film bearings. Convection and conduction of heat in the thin film displaces the hot spot, which is the hottest circumferential position in the thin film, from -20 to 40 degrees ahead of the high spot, where the minimum film clearance is experienced. The temperature differential across the journal causes a bending moment and the corresponding thermal bow in the rotating frame acts like a distributed synchronous excitation in the fixed frame. This thermal bow may cause increased vibrations and continued growth of the synchronous orbit into a limit cycle. The SIF is developed assuming that the response of the rotor-lubricant-bearing dynamic system is much quicker than that of the bearing-journal thermal system, and it is defined as the ratio between the simulation time of the thermal system and the rotor-spinning period. The use of the SIF is unavoidable for efficient computing. The value of the SIF is chosen empirically by the software users as a value between 100 and 400. However, the effect of the SIF on Morton effect simulation results has not been investigated. This research produces simulation results with different values of SIF.

Fabrication and Time-Dependent Analysis of Micro-Hole in GaAs(100) Single Crystal Wafer Using Wet Chemical Etching Method (습식 화학적 식각 방법에 의한 시간에 따른 GaAs(100) 단결정 웨이퍼에서의 마이크로 구멍의 제작 및 분석)

  • Lee, Ha Young;Kwak, Min Sub;Lim, Kyung-Won;Ahn, Hyung Soo;Yi, Sam Nyung
    • Korean Journal of Materials Research
    • /
    • v.29 no.3
    • /
    • pp.155-159
    • /
    • 2019
  • Surface plasmon resonance is the resonant oscillation of conduction electrons at the interface between negative and positive permittivity material stimulated by incident light. In particular, when light transmits through the metallic microhole structures, it shows an increased intensity of light. Thus, it is used to increase the efficiency of devices such as LEDs, solar cells, and sensors. There are various methods to make micro-hole structures. In this experiment, micro holes are formed using a wet chemical etching method, which is inexpensive and can be mass processed. The shape of the holes depends on crystal facets, temperature, the concentration of the etchant solution, and etching time. We select a GaAs(100) single crystal wafer in this experiment and satisfactory results are obtained under the ratio of etchant solution with $H_2SO_4:H_2O_2:H_2O=1:5:5$. The morphology of micro holes according to the temperature and time is observed using field emission - scanning electron microscopy (FE-SEM). The etching mechanism at the corners and sidewalls is explained through the configuration of atoms.

Implementation and Measurement of Protection Circuits for Step-down DC-DC Converter Using 0.18um CMOS Process (0.18um CMOS 공정을 이용한 강압형 DC-DC 컨버터 보호회로 구현 및 측정)

  • Song, Won-Ju;Song, Han-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.265-271
    • /
    • 2018
  • DC-DC buck converter is a critical building block in the power management integrated circuit (PMIC) architecture for the portable devices such as cellular phone, personal digital assistance (PDA) because of its power efficiency over a wide range of conversion ratio. To ensure a safe operation, avoid unexpected damages and enhance the reliability of the converter, fully-integrated protection circuits such as over voltage protection (OVP), under voltage lock out (UVLO), startup, and thermal shutdown (TSD) blocks are designed. In this paper, these three fully-integrated protection circuit blocks are proposed for use in the DC-DC buck converter. The buck converter with proposed protection blocks is operated with a switching frequency of 1 MHz in continuous conduction mode (CCM). In order to verify the proposed scheme, the buck converter has been designed using a 180 nm CMOS technology. The UVLO circuit is designed to track the input voltage and turns on/off the buck converter when the input voltage is higher/lower than 2.6 V, respectively. The OVP circuit blocks the buck converter's operation when the input voltage is over 3.3 V, thereby preventing the destruction of the devices inside the controller IC. The TSD circuit shuts down the converter's operation when the temperature is over $85^{\circ}C$. In order to verify the proposed scheme, these protection circuits were firstly verified through the simulation in SPICE. The proposed protection circuits were then fabricated and the measured results showed a good matching with the simulation results.

Structural and Electrical Properties of (La,Nd,Sr)MnO3 Ceramics for NTC Thermistor Devices

  • Shin, Kyeong-Ha;Park, Byeong-Jun;Lim, Jeong-Eun;Lee, Sam-Haeng;Lee, Myung-Gyu;Park, Joo-Seok;Lee, Sung-Gap
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.3
    • /
    • pp.292-296
    • /
    • 2022
  • (La0.5Nd0.2Sr0.3)MnO3 specimens were prepared by a solid-state reaction. In all specimens, X-ray diffraction patterns of an orthorhombic structure were shown. The fracture surfaces of (La0.5Nd0.2Sr0.3)MnO3 specimens showed a transgranular fracture pattern be possibly due to La ions (0.122 nm) as a perovskite A-site dopant substituting for Nd ions (0.115 nm) having a small ionic radius. The full-width at half maximum (FWHM) of the Mn 2p XPS spectra showed a value greater than that [8] of the single valence state, which is believed to be due to the overlapping of Mn2+, Mn3+, and Mn4+ ions. The dependence of Mn 2p spectra on the Mn3+/Mn4+ ratio according to sintering time was not observed. Electrical resistivity resulted in the minimum value of 100.7 Ω-cm for the specimen sintered for 9 hours. All specimens show a typical negative temperature coefficient of resistance (NTCR) characteristics. In the 9-hour sintered specimen, TCR, activation energy, and B25/65-value were -1.24%/℃, 0.19 eV, and 2,445 K, respectively.

Autonomic Neuropathy in Adolescents with Diabetes Mellitus (청소년기 당뇨병 환자의 자율신경계 합병증에 관한 연구)

  • Yoo, Eun-Gyong;Ahn, Sun-Young;Kim, Duk Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.6
    • /
    • pp.585-590
    • /
    • 2003
  • Purpose : This study is designed to determine the prevalence of cardiovascular autonomic neuropathy and its relationship to risk factors in adolescents with diabetes mellitus(DM). Methods : Ninety-two diabetic patients(80 with type 1 DM and 12 with type 2 DM), ranging from eight to 26 years of age, were studied for cardiovascular autonomic function, and the relationship to age, duration of diabetes, glycated hemoglobin(HbA1c), urinary albumin excretion, and the presence of diabetic retinopathy and abnormal nerve conduction velocities(NCV) were analysed. Autonomic function was assessed by measuring heart rate variation during valsalva manoeuvre, deep breathing and standing from a lying position(30 : 15 ratio), and postural hypotension. Results : Among patients with type 1 DM, 22.5% had early, 8.7% had definite, and 1.3% had severe autonomic dysfunction, and among patients with type 2 DM, 16.7% had early, 8.3% had definite, and 8.3% had severe autonomic dysfunction. On logistic regression analysis including both type 1 and type 2 diabetic patients, the age of the patient(OR=1.133(1.003-1.279), P<0.05) and duration of diabetes(OR=1.148(1.009-1.307), P<0.05) significantly predicted cardiovascular autonomic dysfunction while HbA1c, blood pressure, urinary albumin excretion, and presence of diabetic retinopathy and abnormal NCV did not. The valsalva ratio was borderline or abnormal in 31.5% of patients, the heart rate variation on deep breathing in 41.3%, the 30 : 15 ratio in 14.1%, and postural hypotension in 9.8% of patients. The valsalva ratio and the heart rate variation on deep breathing significantly predicted cardiovascular autonomic dysfunction, but the 30 : 15 ratio and postural hypotension did not. Conclusion : Cardiovascular autonomic dysfunction was found in 32.6% of diabetic patients and 10.8 % of patients had definite or severe involvement. The risk of cardiovascular autonomic dysfunction increased with the patient's age and the duration of DM. This study suggests that the valsalva ratio and the heart rate variation on deep breathing are the most useful tests in evaluating the cardiovascular autonomic function in children and adolescents with DM.

The Effect of Residual Stress on Magnetoresistance in GMR Head Multilayers (자기기록 MR 헤드 용 다층박막의 자기저항에 미치는 잔류응력 효과)

  • Hwang, Do-Guwn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.322-327
    • /
    • 2003
  • Giant magnetoresistance(GMR) NiO multilayer, which has been used to reading head of highly dense magnetic recording, was fabricated, and oxidized in an air during 80 days to study the dependence of magnetoresistance properties on residual stress in the interfaces. The magnetoresistance ratio and the exchange biasing $field(H_{ex})$ of $NiO(60nm)/Ni_{81}Fe_{19}(5nm)/Co(0.7nm)/Cu(2nm)/Co(0.7nm)/Ni_{81}Fe_{19}(7nm)$ spin valves were increased from 4.9% to 7.3%, and 110 Oe to 170 Oe after natural oxidation in the atmosphere for 80 days, respectively. The sheet resistivity ${\rho}$ decreased from $28{\mu}{\Omega}m$ to $17{\mu}{\Omega}m$, but ${\Delta}p$ did not almost change after the oxidation. Therefore, the increase of MR ratio is due to the decrease in the sheet resistivity. the reduced resistance may result from the increase in the reflection of conduction electrons at the oxidized top surface. Also, the increase in the exchange biasing field is originated from the reduction of residual stress at the interface of $NiO/Ni_{81}Fe_{19}$ according as the aging time increases.

[Mössbauer] Spectroscopic Study of La1/3Sr2/3FeO2.96 under the External Magnetic Field (산소결핍 페롭스카이트 La1/3Sr2/3FeO2.96의 외부 자기장 하에서의 Mössbauer분광학적 연구)

  • Yoon, Sung-Hyun;Jung, Jong-Yong
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.81-84
    • /
    • 2005
  • The origin for the charge disproportionation (CD) transition in polycrystalline $La_{1/3}Sr_{2/3}FeO_{2.96}$ was examined using X-ray diffraction and the external field $M\ddot{o}ssbauer$ssbauer spectroscopy. In order to see how the external magnetic field affects the CD state above its transition temperature, an external magnetic field of up to 6 T was applied either parallel or perpendicular to the $\gamma-ray$ direction with the sample temperature fixed at 225 K, which was above the CD transition temperature. Without an external magnetic field, a completely paramagnetic singlet was obtained in the temperature range of the averaged valence state above the transition temperature, which was interpreted as coming from the average valence $Fe^{3.6+}$. In the longitudinal geometry, a magnetic Zeeman with its intensity ratio 3:0:1:1:0:3 is superimposed to the central singlet. In the transverse geometry, however, the central singlet disappears and only a magnetic component with its intensity ratio 3:4:1:1:4:3 emerges. The existence of a singlet is understood as an evidence of the fast electron-transfer among Fe ions. Since the singlet still exists under the magnetic field, the application of an external field has little effect on the conduction mechanism of hopping electrons.

A New Mode Changable Asymmetric Full Bridge DC/DC Converter having 0 ~ 100 % Duty Ratio (0 ~ 100 % 시비율을 갖는 새로운 모드 가변형 비대칭 풀 브리지 DC/DC 컨버터)

  • Shin, Yong-Saeng;Roh, Chung-Wook;Hong, Sung-Soo;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.103-110
    • /
    • 2010
  • In this paper, a new mode changeable asymmetric full bridge dc/dc converter is proposed to solve the freewheeling current problem of the conventional zero voltage switching(ZVS) phase shift full bridge(PSFB) dc/dc converter of low output voltage and high output current applications. The proposed converter is operated as an asymmetric full bridge converter when the duty cycle is less than 50% and active clamp full bridge converter when the duty cycle is greater than 50%. As a result, since its freewheeling current is eliminated, the conduction loss is lower than that of the conventional ZVS PSFB dc/dc converter. Moreover, ZVS of all power switches can be ensured along a wide load ranges and output current ripple is very small. Therefore, high efficiency of the proposed converter can be achieved. Especially since its operation mode is changed to the active clamp full bridge converter during hold up time and can be operated with 50~100% duty ratio, it can produce the stable output voltage along wide input voltage range. The operational principles, theoretical analysis and design considerations are presented. To confirm the operation, validity and features of the proposed converter, experimental results from a 1.2kW($400V_{dc}/12V_{dc}$) prototype are presented.

Correlation between Surface Electromyography and Conventional Electromyography in Facial Nerve Palsy (안면마비 환자에서 표면 근전도 검사와 통상적 근전도 검사간 상관관계)

  • Jang, Haneul;Yoo, Seung Don;Lee, Jong Ha;Soh, Yunsoo;Kim, Dong Hwan;Chon, Jinmann;Lee, Seung Ah;Kim, Hee-Sang;Yun, Dong Hwan;Kwon, Jung Ho
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.84-90
    • /
    • 2018
  • Objective: To assess the correlation between surface electromyography (SEMG) and conventional EMG in patients with facial nerve palsy. Additionally, compare the discomfort and the time required by the patients in two methods. Method: 36 patients with facial palsy were given nerve conduction studies (NCS) via conventional EMG. Then, the peak root mean square (RMS) values were obtained from the SEMG. We also recorded visual analogue scale (VAS), House-Brackmann scale, and the time required for the examination. Results: Pearson's correlation coefficient between the amplitude loss ratio of the RMS values obtained by SEMG compared to the unaffected side (RSEMG) and the amplitude loss ratio of CMAP amplitudes compared to the unaffected side (RCMAP) was 0.567 at the frontalis, 0.456 at the orbicularis oculi, 0.393 at the nasalis, and 0.437 at the orbicularis oris. An increase in RSEMG is positively correlated with an increase in RCMAP. The mean VAS score with conventional EMG was $3.55{\pm}1.42$, whereas that experienced when using SEMG was $0.11{\pm}0.52$ and the mean time required for conventional EMG was $610{\pm}103.84$ seconds, while that required for SEMG was $420{\pm}86.32$ seconds. Conclusion: This study demonstrated a significant positive correlation between facial muscle activities as measured by SEMG and conventional EMG in patients with facial nerve palsy. SEMG has the benefits of being more comfortable and faster when diagnosing facial palsy.