• Title/Summary/Keyword: conditions of evaporation

Search Result 459, Processing Time 0.03 seconds

EFFECTS OF GAS PRESSURES ON GRANULAR STRUCTURE'S FOR MATION OF ALUMINUM FILMS PREPARED BY PVD PROCESS

  • Lee, Myeong-hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.585-592
    • /
    • 1996
  • In order to investigate the influence of gas pressure in PVD deposition conditions, aluminum films were prepared by vacuum evaporation and ion plating. The crystal orientation and morphology of the films affected by argon gas pressures were characterized by using X-ray diffraction (XRD) and scanning electron micrography (SEM) respectively. With the increasing of argon gas pressure, the preferred orientation of aluminum films exhibited (200) and the diffraction peaks of the films became less sharp and broadened. Film's morphology changed from columnar structure to granular structure with the increase of gas pressure. And the properties of these films on corrosion behaviors were estimated by measuring anodic polarization curves in deaerated 3% NaCl solution. The aluminum films which exhibited granular structure with (200) preferred orientation showed good corrosion resistance.

  • PDF

Studies of VETH Plot for Standard Design of Evaporative Cooling at Summer Glasshouse (하절기 유리온실의 증발냉각 설계기준을 위한 VETH 선도 연구)

  • Woo, Y.H.;Ahn, Y.K.;Kim, D.E.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.20 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Judicious control of high temperature is the most important task for the successful intensive-cultivation of vegetables in glasshouses during the hot summer. Estimation of cooling load and wise selection of suitable equipments and facilities based upon the environmental conditions are essential for the efficient temperature control. A series of experiments were carried out to investigate VETH(ventilation, evapotranspiration, temperature and humidity) plot was prepared for the possible practical application in designing some evaporated cooling methods for the following 9 locations; Seoul, Seosan, Taejeon, Pusan, Cheju, Kwangju, Taegu, Chonju, and Chinju.

Experimental Study of Moisture-Wicking Fabric as Cooling Pad for Novel Rotary Direct Evaporative Cooler

  • Sang-Hwan Park;Jae-Weon Jeong
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.4
    • /
    • pp.335-341
    • /
    • 2023
  • This study proposes a novel rotary direct evaporative cooler and investigates the potential of a moisture-wicking fabric as a cooling pad for the proposed evaporative cooler. The rotary direct evaporative cooler rotates the cooling pad to reduce the water and energy consumption of the pump compared to those of existing direct evaporative coolers. A moisture-wicking fabric is considered as the material of the cooling pad, because of its high moisture-wicking property, enhancing water evaporation. Experiments are performed under various inlet air conditions while measuring the air temperature, relative humidity, air velocity, and differential pressure. The evaporative cooling efficiency and impacts of the inlet air temperature and air velocity on the cooling performance are also evaluated. The results demonstrate the potential of the moisture-wicking fabric as cooling pad of direct evaporative cooler.

Hybridal Analysis of High-Frequency Combustion Instability with Pressure-Coupled Combustion Response Model (압력섭동과 연관된 연소응답모델에 기초한 고주파 연소불안정의 이론-수치적 고찰)

  • 윤웅섭;이길용
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.253-257
    • /
    • 2003
  • Theoretical-numerical analysis of wave instability is conducted with parametric response function model. Fluctuating instantaneous mass evaporation rate functionally coupled with pressure perturbations with phase lag is assumed to examine the validity of the method. With sufficiently large amplitude and less phase lag to perturbation, combustion response is resonant to pressure waves, unstable waves are amplified, and the system is driven to instability. Magnitude of response is a crucial instability parameter in the determination of a stability margins and makes a critical change of balancing conditions between the amplifying and damping acoustic energies. In the phase regime the unstable waves are amplified, whereas, the acoustic waves are attenuated in the out-of-phase regime. In the intermediate regime, no distinct tendency of unstable waves was determined.

  • PDF

Atomic-scale investigation of Epitaxial Graphene Grown on 6H-SiC(0001) Using Scanning Tunneling Microscopy and Spectroscopy

  • Lee, Han-Gil;Choe, Jeong-Heon;Kim, Se-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.125-125
    • /
    • 2012
  • Graphene was epitaxially grown on a 6H-SiC(0001) substrate by thermal decomposition of SiC under ultrahigh vacuum conditions. Using scanning tunneling microscopy (STM), we monitored the evolution of the graphene growth as a function of the temperature. We found that the evaporation of Si occurred dominantly from the corner of the step rather than on the terrace. A carbon-rich $(6{\sqrt{3}}{\times}6{\sqrt{3}})R30^{\circ}$ layer, monolayer graphene, and bilayer graphene were identified by measuring the roughness, step height, and atomic structures. Defect structures such as nanotubes and scattering defects on the monolayer graphene are also discussed. Furthermore, we confirmed that the Dirac points (ED) of the monolayer and bilayer graphene were clearly resolved by scanning tunneling spectroscopy (STS).

  • PDF

The Numerical Study on Prediction of Diesel Fuel Spray Evolution in a Different Types of Nozzle Geometry (노즐 형상에 따른 디젤 연료 분무의 발달 예측에 관한 수치 해석적 연구)

  • Min, Se Hun;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.169-174
    • /
    • 2017
  • The objective of this study was to verify the experimental and numerical results of spray evolution injected from different types of the nozzle-hole geometries. Spray visualization was taken by high speed camera under the different conditions. For the simulations of spray tip penetration, turbulence, evaporation and break-up model were applied K-zeta-f, Dukowicz and Wave model, respectively. Also, the prediction accuracy of spray tip penetration was increased by varying the spray cone angle. At the same time, the results of this work were compared in terms of spray tip penetration, and SMD characteristics. The numerical results of spray evolution process and spray tip penetration showed good agreement with experimental one.

A Study on the Engine Performance and Exhaust Emission with Intake Port Methanol Injection in a DI Diesel Engine (직분식 디젤기관의 메탄올 흡기분사에 의한 기관성능과 배기배출물에 관한 연구)

  • 김명수;라진홍;안수길
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.249-256
    • /
    • 2000
  • In order to investigate the effectiveness of methanol, which has high latent heat of evaporation and oxygen contents, for DI diesel engine performance and exhaust emission, the methanol was injected at the suction port of DI diesel engine. The injector used for test was conventional gasoline engine injector and controlled the quantity of methanol per cycle by the power supply controller which designed specially for injector. The results shown that the maximum pressure point was delayed, the value of maximum pressure was decreased, and the concentrations of both NOx and Soot were decreased, as the methanol injection quantity increased, and also the thermal efficiency of engine injected methanol under the high load condition was similar to no methanol injection but under the medium load condition was decreased within the experimental conditions.

  • PDF

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

A Study on the Ignition Delay of Fish Oil Using a Constant Volume Combustion Bomb (정용연소장치에 의한 어유의 착화지연에 관한 연구)

  • 서정주;왕우경;안수길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.1
    • /
    • pp.50-58
    • /
    • 1993
  • The ignition delay of diesel oil and fish oil blended with diesel oils was investigated at various pressure and temperature conditions in a constant volume combustion bomb. The evaporation and combustion duration of diesel oil and fish oil blended with diesel oils were respectively different in high and low temperature. The dependence of ignition delay on the temperature was different in high and low temperature ranges which were divided at the 773K. The dependence of ignition delay on the pressure was almost linear, regardless of the test fuels at the constant temperature(863K). The ignition delay became longer as the blending rate of fish oil increased at the constant temperature and pressure, but it was especially short with 20% fish oil blended with diesel oils.

  • PDF

A Properties of n-CdS/p-InP Heterojunction Diodes (n-CdS/P-InP 이종접합 다이오드 특성)

  • 송복식;문동찬;김선태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.60-63
    • /
    • 1993
  • We have prepared n-CdS/p-InP hetero- junction solar cells by thermal evaporation. The efficiency under the optium conditions without the grid line contact was 7.3%, and the solar cell having glid line contact with SiO AR coating was the open circuit voltage of 0.71V, the short circuit voltage current density of 15mA/cm$^2$, the fill factor of 0.73, and the efficiency of 11.5%. As result of photoresponse in 400-1000nm wavelength the cutoff of n-CdS/p-InP solar at 500nm results from absorption by the CdS \"window\" and the cutoff at 930 nm result from absorption by the InP.

  • PDF