• Title/Summary/Keyword: concrete durability.

Search Result 2,150, Processing Time 0.027 seconds

Fundamental Study of Polymer-modified Cement Mortar for Maintenance in Concrete Structure According to Ambient Temperature (온도에 따른 콘크리트 구조체 단면 보수용 폴리머 모르타르의 기초적 연구)

  • Seo, Jung-Pil;Kim, Jae-Won;Lee, Jung-Koo;Choi, Hun-Gug;Kang, Cheol;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.59-62
    • /
    • 2007
  • Nowadays, polymer-cement mortars are widely used in construction field(floorings and pavements, water-proofings, adhesives, repair materials, deck coverings, anti-corrosive linings) Because of excellent performance such as high tensile and flexural strength, waterproofness, excellent adhesion, good durability, improved wear and chemical resistances. This article presents the results of experimental study that investigates the effect of ambient temperature on the strength properties of polymer-modified cement mortar. Results show that when increasing the polymer proportion in mortar on different ambient temperature, the compressive strength and flexural strength are decreased, and also alkali resistance is decreased.

  • PDF

A Review Study on the Application of γ-C2S (γ-C2S 활용에 관한 문헌적 연구)

  • Chen, zheng-xin;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.118-119
    • /
    • 2016
  • γ-C2S is known as a kind of substance that it does not react with water at room temperature. However it could react with the CO2 producing CaCO3 and silica gel as the carbonation products. Thus γ-C2S can be used as a mineral addition to improve the compressive strength and durability of concrete. On the other hand, the manufacture of γ-C2S can give an effective utilization of industrial by-product with low energy consumption and low CO2 emission. This paper aims to summarize the development situation on this field.

  • PDF

Strength Properties of Cement Matrix using Phytoncide (피톤치드를 혼입한 시멘트경화체의 강도 특성)

  • Kim, Hyeon-Sung;Kim, Sun-A;Park, Sun-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.23-24
    • /
    • 2018
  • Most finishing materials are vulnerable to durability, humidity resistance and fire. And those products used formaldehyde to protect, during the manufacturing process. Also most finishing materials used adhesives to construction process indoor. All of these elements are major causes of releasing formaldehyde. In this study, concrete used by phytoncide was examined to remove the formaldehyde. As a result of the experiment, we found that compressive strength was increased and formaldehyde effectively removed by using mixture of cement matrix and phytoncide.

  • PDF

A Study on the field application analysis for high adhesive spray type of degenerated and rubberized asphalt membrane material (스프레이식 고점착 변성 고무 아스팔트 도막 방수재의 재료 및 공법에 관한 실험적 연구)

  • Oh, Sang-Keun;Song, Je-Young;Kim, Jin-Seong;Lee, Nam-Kyoo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.61-65
    • /
    • 2006
  • Urethane, epoxy, acrylic have common property to adhere on the concrete dried surface in the waterproofing materials at present. In the wet condition, however, the materials such as urethane, epoxy, acrylic need a long hardening time and it become a reason of water leakage as the materials breaking down. it is one of the problem to adhere to the substrate. Therefore, in this thesis, I focused to assure the structural safety and durability and quality for waterproofing and safe of construction cost by cut down the cost of labor and reduce the term of works as searching the application of field condition for hish adhesive spray type of degenerated and rubberized asphalt membrane material.

  • PDF

Mock-up Test for Nuclear Power Plant Rebar Modulation Applying Febrication (선조립공법을 활용한 원전구조물 철근모듈화 Mock-up 실험연구)

  • Lim, Sang-Jun;Lee, Byung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.13-14
    • /
    • 2015
  • To minimize construction of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop appication design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are. After reviewing the rebar drawing of the NPP structures and performing the mock-up test, the rebar modulation method in the various area of the NPP Structure has been established.

  • PDF

A Study on the Application of Water Leakage Repair Materials through the Performance Evaluation of Polyacrylic Resin. (폴리아크릴 레진의 누수보수재 성능평가)

  • Cho, Il-Kyu;Yuh, Jae Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.193-194
    • /
    • 2018
  • In this study, various materials such as epoxy material, urethane material, cement material, and acrylic material are used to solve the water leakage occurring in underground structures. However, in the reality that the durability is insufficient and the effect is insufficient, it is aimed to improve the repairing effect by using acrylics. As a second study, it is confirmed that leachate can be used as a repair material by considering long time under water stability, elongation range test, fatigue resistance test, tube stability test, damage recovery performance ana temperature stability considering leakage environment for polyacrylate. In addition, this material is applied to Expansion Joint to perform leakage repair, and to verify the effect of repairing leakage by monitoring and visual observation of concrete humidification.

  • PDF

Standard Manual for the Diagnosis and Repairing Leakage Cracks of Underground Structures in Apartment Housing - Maintenance Diagnosis - (공동주택 부위별 표준 누수 진단 매뉴얼 - 유지관리 진단 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Lee, Sung Jin;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.191-192
    • /
    • 2018
  • This study presents the standard methods of diagnosis and repair to prevent and maintain the durability degradation caused by leakage cracks in underground structures in Korea. The third part after the announcement of the existing maintenance plan, The environmental characteristics and leakage condition of underground structures, the causes of deterioration of underground concrete structures, and countermeasures and leakage equipment were described.

  • PDF

Workability evaluation of HPFRCC depending on mixing proportions (배합비 변화에 따른 HPFRCC의 유동성 평가)

  • Park, Jae-Yong;Kang, Byeong-Hoe;Park, Yong-Jun;Han, Dong-Yeop;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.150-151
    • /
    • 2014
  • Although there has been many research regarding improving anti-shock performance and durability of concrete using fiber-reinforcement, there are still drawback on workability with interruption of fibers such as fiber-ball. Hence to solve this problem, in previous research, the optimum combination of fibers to improve workability of HPFRCC. In this research, based on the result of previous research, to improve the workability further, various fine aggregate contents is evaluated on workability, and the most appropriate mixing proportion is suggested.

  • PDF

Evaluating Insulation Performance of Form-tie in Sandwich Insulation Wall (폼타이 종류에 따른 중단열 벽체의 단열성능 평가)

  • Park, Jun-Ho;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.188-189
    • /
    • 2014
  • Nowadays, many research execute about sandwich-insulation wall for durability of wall and retaining insulation performance. But sandwich-insulation, different exterior and interior insulation, need to form-tie which supporting both side form. And because of it penetrate concrete wall, it is worried about thermal-bridge phenomenon to form-tie. So, this research classify penetration type and buried type and analysis thermal-phenomenon of each type's form-tie and insulation performance. As a result, all form-tie type little occur thermal-bridge but penetration form-tie have superior insulation performance and low U-value.

  • PDF