• 제목/요약/키워드: concrete cover

검색결과 583건 처리시간 0.028초

생태하천 복원 방안 (Suggestions for Ecological Stream Restoration)

  • 김명진
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.59-68
    • /
    • 2007
  • Urban streams have been severely degraded with wastewater and concrete structure over a prolonged period. The Chonggyecheon Restoration Project recovered a stream in the downtown Seoul with landscaping, plantings and bridges after the cover concrete and elevated asphalt road were removed. The project has been criticized partly because it is not an ecological restoration but rather the development of an urban park with an unnaturally straight flowing stream, artificial building structures, and artificial water pumping from the Han River. Nevertheless, the public have praised the project and almost 100,000 visitors per day come to see the reeds, catfish, and ducks. The stream restoration project is attractive to central and regional government decision makers because it increases the public concern of landscape amenity. Several projects such as Sanjichon and Kaeumjungchon are on going and proposed. These projects have a common and different respect in scope and procedure. The Chonggyecheon project in the process of environmental impact assessment (EIA) and prior environmental review system (PERS) reviewed the environmental impacts before development. Kaeumjungchon in the PERS and Sanjichon without EIA and PERS are reviewed. EIA and PERS systems contribute to checking the ecological sustainability of the restoration projects. A stream restoration project is a very complex task, so an integrated approach from plan to project is needed for ecologically sound restoration. Ecological stream restoration requires 1) an assessment of the entire stream ecosystem 2) establishing an ecologically sound management system of the stream reflecting not only benefits for people but also flora and fauna; 3) developing the site-specific design criteria and construction techniques including habitat restoration, flood plains conservation, and fluvial management; 4) considering the stream watershed in land use plan, EIA, PERS, and strategic environmental assessment (SEA). Additionally the process needs to develop the methodologies to enhance stakeholder's participation during planning, construction, and monitoring.

쪼갬파괴가 발생된 GFRP 보강근을 사용한 이음길이 산정식 (Equation of the Development Length for the Pullout tests with GFRP Reinforcement having Splitting Failure)

  • 하상수;최동욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.859-862
    • /
    • 2008
  • 본 연구는 GFRP 보강근의 정착길이 산정식을 제안하는 것이다. 정착길이 산정식을 제안하기 위해 인발실험을 실시하였다. 실험변수는 묻힘길이, 피복두께, 보강근 직경, 보강근 종류이다. 묻힘길이는 15d$_b$, 30d$_b$, 45d$_b$로 하고, 순 피복두께는 0.5d$_b$, 1.0d$_b$, 1.5d$_b$, 및 2.0d$_b$로 계획하였다. 사용된 보강근은 모두 3종류(국내 2종, 국외 1종)이고 보강근 크기는 D10, D13, D16이다. 실험은 겹침이음된 GFRP 보강근 양 단부를 동시에 인발하여 최종파괴에 도달될 때까지 GFRP 보강근에 하중을 가력하였다. 인발실험을 통해 얻은 결과를 토대로 각 변수에 따른 GFRP 보강근의 부착특성 및 평균부착응력을 산정하였으며, 실험체중 쪼갬파괴된 실험체만을 선택하여 회귀분석을 통해 정착길이 산정식은 제안하였고 ACI 440.1R-06에 제안하고 있는 식과 비교하였다. 본 연구를 통해 제안된 회귀분석에 의한 제안식을 근거로 겹침이음된 GFRP 보강근을 이용한 휨 설계가 가능할 것으로 판단된다.

  • PDF

GPR을 이용한 콘크리트 내 공동 탐사 (Detection of Delamination inside Concrete Using Ground Penetrating Radar)

  • 임홍철;이숭재;우상균;송영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.177-184
    • /
    • 2003
  • 비파괴 검사에 널리 쓰이는 Ground Penetrating Radar (GPR)의 콘크리트내 공동 탐사 성능을 알아보기 위해, 일련의 실험을 실시하였다. 공동 탐사는 사용하는 안테나의 주파수에 가장 큰 영향을 받으며, 실험에서는 900 MHz, 1 GHz, 1.5 GHz 3개의 안테나를 사용하였다. 콘크리트 기본시편의 크기는 1,000 mm (길이) ${\times}$ 600 mm (폭) ${\times}$ 140 mm (두께)이고, 공동은 200 mm (길이) ${\times}$ 600 mm (폭) ${\times}$ 50 mm (두께)의 크기를 갖고 있다. 공동의 매립 깊이를 20 mm, 30 mm, 60 mm, 70 mm 4개고 달리한 결과, 모든 경우에서 공동을 성공적으로 탐사하였으며, 각 안테나 주파수에서의 특성을 파악하였다. 또한 상업용 레이더 시스템의 영상 처리 결과를 향상시킨 결과를 논문에서 다루었다.

반복 횡하중을 받는 원형 철근콘크리트 기둥의 Helical Bar 보강효과에 대한 연구 (Study on Reinforcement Effect of Circular RC Columns by Helical Bar Under Cyclic Lateral Load)

  • 김성겸;박종권;한상희;김병철;장일영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.48-58
    • /
    • 2014
  • 본 연구에서는 1992년 도로교설계기준의 내진설계도입 이전 규정에 따라 설계, 시공된 교각의 축소 모델을 실험체로 제작하여 원형기둥의 변위비에 따른 횡하중을 변위제어 방식으로 입력하여 준정적 방법을 통해 실험을 실시하였다. 연구에 적용한 보강재는 성능을 향상시킨 무기계 합금강인 Helical Bar로써 원형기둥 외부에 보강 후 실내실험을 통하여 파괴거동, 하중-변위 관계, 연성도 평가 및 에너지 평가를 실시하였다. 실험변수로는 위험단면 내에서 나선으로 보강한 보강재의 단면력의 크기와 나선보강의 간격, 보강형태로 두었으며, 준정적 실험을 통해 보강성능의 차이와 효과를 확인하였다. 실험결과 보강대상 부재의 성능에 따라 적절한 보강재의 단면력 크기결정과 보강간격 및 형식의 선정이 필요하며 기계적 보강재뿐만 아니라 고강도 콘크리트 피복으로의 치환으로도 보강성능이 향상됨을 확인할 수 있었다.

Experimental investigation of shear connector behaviour in composite beams with metal decking

  • Qureshi, Jawed;Lam, Dennis
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.475-494
    • /
    • 2020
  • Presented are experimental results from 24 full-scale push test specimens to study the behaviour of composite beams with trapezoidal profiled sheeting laid transverse to the beam axis. The tests use a single-sided horizontal push test setup and are divided into two series. First series contained shear loading only and the second had normal load besides shear load. Four parameters are studied: the effect of wire mesh position and number of its layers, placing a reinforcing bar at the bottom flange of the deck, normal load and its position, and shear stud layout. The results indicate that positioning mesh on top of the deck flange or 30 mm from top of the concrete slab does not affect the stud's strength and ductility. Thus, existing industry practice of locating the mesh at a nominal cover from top of the concrete slab and Eurocode 4 requirement of placing mesh 30 mm below the stud's head are both acceptable. Double mesh layer resulted in 17% increase in stud strength for push tests with single stud per rib. Placing a T16 bar at the bottom of the deck rib did not affect shear stud behaviour. The normal load resulted in 40% and 23% increase in stud strength for single and double studs per rib. Use of studs only in the middle three ribs out of five increased the strength by 23% compared to the layout with studs in first four ribs. Eurocode 4 and Johnson and Yuan equations predicted well the stud strength for single stud/rib tests without normal load, with estimations within 10% of the characteristic experimental load. These equations highly under-estimated the stud capacity, by about 40-50%, for tests with normal load. AISC 360-16 generally over-estimated the stud capacity, except for single stud/rib push tests with normal load. Nellinger equations precisely predicted the stud resistance for push tests with normal load, with ratio of experimental over predicted load as 0.99 and coefficient of variation of about 8%. But, Nellinger method over-estimated the stud capacity by about 20% in push tests with single studs without normal load.

철도터널 내화성능 기술개발을 위한 내화성능 확보방안에 관한 연구 (Study on the Effective Method of Fire Protection Technology in Railway Tunnel Fire)

  • 박경훈;김흥열;김형준
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.86-91
    • /
    • 2010
  • 터널 내의 화재발생시 약 $1300^{\circ}C$이상으로 추정되는 고열에 의한 제반설비의 훼손, 콘크리트 구조체의 폭렬현상으로 인한 심각한 구조적 손상 및 이로 인한 내력구조물의 붕괴로 유발되는 2차적 화재피해의 가능성이 높으므로, 터널구조물의 내화설계 분야에 대한 대응기술개발이 추진되어야 할 시점이다. 하지만 국내에서는 화재에 의한 인적 경제적 피해를 최소화하기 위한 연구는 주로 일반건축구조물의 내화구조 대상건축물, 내화구조 공법, 시험방법 및 성능기준 등에만 집중되어 있으며 터널 내에서의 화재실험 및 내화구조 연구는 거의 전무하다. 따라서 터널 내 화재 발생에 따른 구조물의 역학적 거동특성 및 손상범위 파악 등과 같은 연구가 절실히 요구되고 있는 실정이다. 본 연구에서는 터널의 구조요소에 대한 화재거동 실증실험을 통해 터널 구조요소별 화재손상 범위 및 내화재료 최소시공두께를 선정하였다.

피로 및 내구성을 고려한 LNG 저장탱크의 수명평가 프로그램 개발 (The Development of Life Evaluation Program for LNG Storage Tank considering Fatigue and Durability)

  • 김정훈;김영구;조영도
    • 한국가스학회지
    • /
    • 제21권3호
    • /
    • pp.39-45
    • /
    • 2017
  • LNG 산업의 핵심시설인 LNG 저장탱크는 주로 9% 니켈강형 내조와 프리스트레스 콘크리트의 외조로 구성되어 있다. 1896년 상업운전 이후 내조의 피로와 외조의 내구성 저하로 인한 구조물 성능 열화의 위험성 증대에 선제적으로 대응할 수 있도록 수명평가 프로그램이 필요하다. 이 연구는 LNG 저장탱크의 내조에 대해 피로평가와 외조의 내구성(탄산화, 염해)을 평가할 수 있는 수명평가 프로그램을 개발하였다. 내조 탱크는 3가지의 주요 시나리오를 정의하여 구조해석과 마이너 손상법칙이 적용된 피로수명 해석이 수행된다. 외조 탱크의 탄산화 평가는 이산화탄소 함량과 침투 깊이 데이터를 이용하여 콘크리트 피복두께에 따른 탄산화 진전을 예측한다. 외조 탱크의 염해 평가는 다양한 입력조건 고려와 신뢰도 있는 결과를 도출하기 위해 공개 프로그램인 Life-365프로그램에 연계하는 방안으로 구축하였다.

Dynamic behavior of SRC columns with built-in cross-shaped steels subjected to lateral impact

  • Liu, Yanhua;Zeng, Lei;Liu, Changjun;Mo, Jinxu;Chen, Buqing
    • Structural Engineering and Mechanics
    • /
    • 제76권4호
    • /
    • pp.465-477
    • /
    • 2020
  • This paper presents an investigation on the dynamic behavior of SRC columns with built-in cross-shaped steels under impact load. Seven 1/2 scaled SRC specimens were subjected to low-speed impact by a gravity drop hammer test system. Three main parameters, including the lateral impact height, the axial compression ratios and the stirrup spacing, were considered in the response analysis of the specimens. The failure mode, deformation, the absorbed energy of columns, as well as impact loads are discussed. The results are mainly characterized by bending-shear failure, meanwhile specimens can maintain an acceptable integrity. More than 33% of the input impact energy is dissipated, which demonstrates its excellent impact resistance. As the impact height increases, the flexural cracks and shear cracks observed on the surface of specimens were denser and wider. The recorded time-history of impact force and mid-span displacement confirmed the three stages of relative movement between the hammer and the column. Additionally, the displacements had a notable delay compared to the rapid changes observed in the measured impact load. The deflection of the mid-span did not exceed 5.90mm while the impact load reached peak value. The impact resistance of the specimen can be improved by proper design for stirrup ratios and increasing the axial load. However, the cracking and spalling of the concrete cover at the impact point was obvious with the increasing in stiffness.

강재 플레이트 유한요소해석을 이용한 잔교 상부의 풀 박스 부재의 선정 (Design of Pull Box Members on the Landing Pier Using Finite Element Analysis of a Steel Plate)

  • 김성원;홍혜민;한택희;서승남
    • 한국연안방재학회지
    • /
    • 제4권3호
    • /
    • pp.111-118
    • /
    • 2017
  • In this study, pull box members were designed by finite element analysis of a steel plate covering a pull box to secure its safety on the landing pier dedicated to the large research survey ship. It was assumed that the maximum load is due to the 250 tonf class crane used for unloading work when the working environment in the upper part of the landing pier was considered. The safety of the pull box was evaluated by the comparison between the yield strength of the steel plate and the result of stress analysis on the steel plate due to the crane load. It was found that the stress at the plate from the crane load exceeded the yield strength of the steel(205MPa) when the upper part of the pull box was protected by a $1950{\times}1950mm$ steel plate cover. In order to compensate for this, a concrete filled steel tube(CFT) column with a diameter of 150 mm and a steel thickness of 10 mm was reinforced at the center of the plate, and the finite element analysis was carried out. However, the maximum stress at the steel plate was higher than the yield strength of the steel in some load cases so that it was tried to find appropriate thickness of the steel plate and diameter of the CFT columns. Finally, the analysis results showed that the safety of the pull box was secured when the thickness of the steel plate and the diameter of the CFT column were increased to 30mm and 180mm, respectively.

긴장재 절단에 따른 프리텐션 부재의 동적 거동 고찰 (Dynamic Behavior of Pretensioned Concrete Member during Detensioning)

  • 김장호;문도영;지광습;김규선
    • 대한토목학회논문집
    • /
    • 제28권5A호
    • /
    • pp.747-756
    • /
    • 2008
  • 본 논문에서는 전달길이에 영향을 미치는 인자에 따라 프리텐션 부재가 받는 동적 충격에 의한 영향을 실험적으로 고찰하였다. 이를 위해 긴장재의 직경, 콘크리트의 피복 두께, 구속 철근과 비부착 구간의 유무, 긴장력 도입 방식을 변수로 한 10개의 프리텐션 콘크리트 부재를 제작하고, 긴장재에 부착한 전기 저항식 변형률 게이지를 통하여 부재에 긴장력 도입 시 변형률 변화를 동적으로 측정하였다. 실험 결과, 순간 전달 방식으로 긴장력을 도입할 때 절단단부에서 큰 동적 효과가 발생하는 것을 확인할 수 있었다. 또한, 변형률 변화량으로 각 부재의 긴장력을 비교한 결과, 각 인자에 따라 차이가 존재하는 것을 확인했다. 직경 15.2 mm 강선보다 12.7 mm 강선의 잔류 긴장력 비율이 더 컸으며, 75 mm의 콘크리트 피복 두께만으로도 충분한 구속 효과를 기대할 수 있는 것으로 판단된다. 구속 철근의 영향은 미미했고, 비부착 구간의 영향으로 잔류 긴장력이 향상되었다. 순간 전달 방식보다 지연 전달 방식으로 긴장력을 도입할 때 긴장력 손실이 적은 것으로 확인되었다.