Detection of Delamination inside Concrete Using Ground Penetrating Radar

GPR을 이용한 콘크리트 내 공동 탐사

  • Received : 2002.06.29
  • Published : 2003.04.30

Abstract

A series of experimental work has been conducted to evaluate the capability of Ground Penetrating Radar (GPR) system in detecting delamination inside concrete. Three antenna at 900 MHz, 1000 MHz, and 1500 MHz frequency are used in the experiments for laboratory size specimens, and 400 MHz antenna has been used for a large size specimen. The laboratory size specimens have the dimensions of 1,000 mm (length) ${\times}$ 600 mm (width) ${\times}$ 140 mm (thickness) with a delamination of 200 mm (length) ${\times}$ 600 mm (width) ${\times}$ 140 mm (thickness). The cover depth of the delamination is varied as follows: 20 mm, 30 mm, 60 mm, and 70 mm. In all cases, the delamination has been successfully identified. The property of three frequencies was seized about detecting delamination. Also, it was shown that the image results in GPR were improved by signal processing.

비파괴 검사에 널리 쓰이는 Ground Penetrating Radar (GPR)의 콘크리트내 공동 탐사 성능을 알아보기 위해, 일련의 실험을 실시하였다. 공동 탐사는 사용하는 안테나의 주파수에 가장 큰 영향을 받으며, 실험에서는 900 MHz, 1 GHz, 1.5 GHz 3개의 안테나를 사용하였다. 콘크리트 기본시편의 크기는 1,000 mm (길이) ${\times}$ 600 mm (폭) ${\times}$ 140 mm (두께)이고, 공동은 200 mm (길이) ${\times}$ 600 mm (폭) ${\times}$ 50 mm (두께)의 크기를 갖고 있다. 공동의 매립 깊이를 20 mm, 30 mm, 60 mm, 70 mm 4개고 달리한 결과, 모든 경우에서 공동을 성공적으로 탐사하였으며, 각 안테나 주파수에서의 특성을 파악하였다. 또한 상업용 레이더 시스템의 영상 처리 결과를 향상시킨 결과를 논문에서 다루었다.

Keywords