Computed tomography and magnetic resonance imaging features of suspected transitional cell carcinoma lesions involving the bladder, prostate, and urethra in a dog: a case report

  • Wooseok Jin;Sang-Kwon Lee;Seulgi Bae;Taeho Oh;Kija Lee
    • 대한수의학회지
    • /
    • 제63권4호
    • /
    • pp.39.1-39.5
    • /
    • 2023
  • A 14-year-old, spayed female, poodle was presented with dysuria and hematuria. A mass that appeared hypoechoic on ultrasound and hypoattenuating on computed tomography (CT) extended from the bladder neck to the urethra. Magnetic resonance imaging (MRI) showed the mass invading the muscular layer of the bladder, urethra, and prostate with distinct margins. Transitional cell carcinoma (TCC) was confirmed with the CADET-BRAF test. This study describes the CT and MRI features of suspected TCC lesions involving the bladder, prostate, and urethra. MRI showed superior soft tissue contrast resolution, enabling evaluation of invasion of the muscular layer of the bladder and urethra.

심낭오목: 다양한 질환에서의 CT 소견 (Pericardial Recess: Computed Tomography Findings of Varying Disorders)

  • 서진호;김영통;조성식;박찬호
    • 대한영상의학회지
    • /
    • 제81권6호
    • /
    • pp.1364-1376
    • /
    • 2020
  • 심낭오목은 흉부 컴퓨터단층촬영을 받는 환자에서 종종 확인이 된다. 심낭은 종종 정상 변이나 질환과 오인될 수 있어 심낭의 정상 해부학 구조를 알고 있는 것이 중요하다. 그러므로 이 논문에서는 심낭오목의 해부학 및 위치 그리고 심낭오목과 관련된 다양한 질환에서 보일 수 있는 특징적인 소견에 대해 기술할 것이다.

Micro-computed tomographic evaluation of the effect of fluoride agents on white spot lesions: An in vitro study

  • Hong, Sook-Chan;Lee, Dong-Yul;Kim, Yae-Jin
    • 대한치과교정학회지
    • /
    • 제52권1호
    • /
    • pp.75-79
    • /
    • 2022
  • Objective: To investigate remineralizing effect of three fluoride regimens on artificially demineralized enamel around orthodontic bracket by analyzing mineral density (MD) acquired from micro-computed tomography (micro-CT). Methods: Forty-eight bracket bonded bovine incisors were prepared to create demineralized enamel (DE) surface. The samples were divided into four groups according to the fluoride regimen: 1) no fluoridation, 2) 1.23% acidulated phosphate fluoride (APF) gel, 3) fluoridated toothpaste, and 4) 0.05% sodium fluoride mouthwash. Micro-CT was scanned after demineralization (T0), and 2 weeks (T1) and 4 weeks (T2) of fluoridation. Results: APF gel showed highest remineralization of DE during T1-T0 interval among the groups (p < 0.05); followed by toothpaste, mouthwash and no fluoridation. APF gel and toothpaste demonstrated significant increase in MD after 4 weeks of application (p < 0.05). Conclusions: Remineralization effects of three fluoride regimens were depicted through micro-CT analysis, of which APF gel was most effective.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권2호
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

Does Simultaneous Computed Tomography and Quantitative Computed Tomography Show Better Prescription Rate than Dual-energy X-ray Absorptiometry for Osteoporotic Hip Fracture?

  • Ko, Jae Han;Lim, Suhan;Lee, Young Han;Yang, Ick Hwan;Kam, Jin Hwa;Park, Kwan Kyu
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.233-240
    • /
    • 2018
  • Purpose: This study aimed to evaluate the efficacy of simultaneous computed tomography (CT) and quantitative CT (QCT) in patients with osteoporotic hip fracture (OHF) by analyzing the osteoporosis detection rate and physician prescription rate in comparison with those of conventional dual-energy X-ray absorptiometry (DXA). Materials and Methods: This study included consecutive patients older than 65 years who underwent internal fixation or hip arthroplasty for OHF between February and May 2015. The patients were assigned to either the QCT (47 patients) or DXA group (51 patients). The patients in the QCT group underwent QCT with hip CT, whereas those in the DXA group underwent DXA after surgery, before discharge, or in the outpatient clinic. In both groups, the patients received osteoporosis medication according to their QCT or DXA results. The osteoporosis evaluation rate and prescription rate were determined at discharge, postoperative (PO) day 2, PO day 6, and PO week 12 during an outpatient clinic visit. Results: The osteoporosis evaluation rate at PO week 12 was 70.6% (36 of 51 patients) in the DXA group and 100% in the QCT group (P<0.01). The prescription rates of osteoporosis medication at discharge were 70.2% and 29.4% (P<0.001) and the cumulative prescription rates at PO week 12 were 87.2% and 60.8% (P=0.003) in the QCT and DXA groups, respectively. Conclusion: Simultaneous CT and QCT significantly increased the evaluation and prescription rates in patients with OHF and may enable appropriate and consistent prescription of osteoporosis medication, which may eventually lead to patients' medication compliance.

엑스선 컴퓨터 단층면 조사를 통한 나전연상 백골의 제작기법 연구 (Study of the Production Method of the Framework of Lacquerware Inlaid with Mother-of-pearl Using X-ray Computed Tomography)

  • 박영만;양석진
    • 박물관보존과학
    • /
    • 제24권
    • /
    • pp.75-80
    • /
    • 2020
  • 엑스선 컴퓨터 단층면의 관찰은 문화재의 내부 구조조사를 위한 것으로 육안으로 확인할 수 없는 칠기 공예품의 제작 기법을 조사하는데 매우 유용한 방법이다. 특히 나전칠기는 옻칠과 나전을 사용하여 제작한 한국 전통공예품으로써 매우 중요한 연구 대상품이다. 하지만 특수한 환경에서 구조적으로 손상되어 있지 않는 한 백골의 제작기술을 파악하기에는 어렵다. 그 동안의 나전칠기 공예품의 가치 연구는 옻칠 기법과 나전 공예기술에 관한 연구가 주류가 되고 있지만 나전칠기의 뼈대가 되는 백골의 제작기법에 관한 연구는 이루어지지 않고 있는 실정이다. 본 연구는 조선시대 나전칠기에 대하여 컴퓨터 단층촬영[CT: Computed Tomography]을 실시하여 나전칠기 백골의 재질과 목공기술에 대한 결과를 제공하였다. 목재는 침엽수를 사용하였고 기둥목과 쇠목(기둥과 기둥 사이를 가로질러 대는 목재)의 결합은 삼방연귀짜임 방식을 사용하였으며 그 외의 결구 방법은 못을 사용하였음을 알 수 있었다.

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

  • Kim, Ho Jin;Mun, Da Na;Goo, Hyun Woo;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • 제50권2호
    • /
    • pp.71-77
    • /
    • 2017
  • Background: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: $197mL/m^2$ vs. $175mL/m^2$, p=0.008; median LV-EDVI: $94mL/m^2$ vs. $92mL/m^2$, p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향 (Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography)

  • 김기덕;박창서
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

요오드 조영제를 이용한 전산화단층촬영장치의 자가진단 직선성 정도관리 기술 개발 (Development of Self-Diagnosis Linearity Quality Assurance Technique in Computed Tomography by Using Iodic Contrast Media)

  • 성열훈
    • 한국콘텐츠학회논문지
    • /
    • 제15권5호
    • /
    • pp.436-443
    • /
    • 2015
  • 본 연구는 요오드 함량이 다른 조영제를 증류수로 희석한 비율과 관전압의 조건별로 CT number를 측정하여 전산화단층촬영장치의 자가진단 직선성 정도관리 기술을 개발하고자 하였다. 사용된 장비는 4-채널 MDCT를 이용하였고, 요오드 조영제는 300 mgI/ml, 350 mgI/ml, 370 mgI/ml, 400 mgI/ml를 사용했다. 증류수에 대한 조영제 희석비율은 최대 농도값이 측정될 때까지 5%씩 증가하였다. 관전압은 90 kVp, 120 kVp, 140 kVp를 적용하였다. 그 결과, 90 kVp에서 400 mgI/ml 조영제가 5% ~ 25%에서 희석된 비율 구간과 CT number들 간의 상관계수가 0.993으로 가장 근사한 직선성을 구하였다. 본 연구에서 제시한 요오드 조영제를 이용한 자가진단 직선성 평가는 AAPM CT 성능평가용 팬톰을 대체할 수 있는 정도관리 방법으로 이용할 수 있다.