• Title/Summary/Keyword: computed

Search Result 12,209, Processing Time 0.097 seconds

The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing (골결손부 치유과정에서 cone beam형 전산화단층영상의 정확도)

  • Kang, Ho-Duk;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-77
    • /
    • 2007
  • Purpose: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Materials and Methods: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multi planar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. Results: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based methologies. Conclusion: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.

  • PDF

Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

Comparison of Echocardiography and Computed Tomography on Cardiac Wall Thickness and Internal Dimension Size of Left Ventricle in Normal Adults (정상 성인의 좌심실 벽두께와 내강 크기에 대한 심초음파영상과 전산화단층영상의 비교)

  • Ji, Myeong-Hoon;Kim, Seoung-Hwan;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.545-552
    • /
    • 2018
  • The purpose of this study was evaluated the relationship between echocardiography and cardiac computed tomography in normal adults by visual assessment, and evaluated the effective doses of cardiac computed tomography. The subjects were 100 normal patients who visited two general hospitals in Chungnam, from January 1 to May 30, 2018. We obtained images by using these modalities and evaluated the wall thickness and internal dimension of the Left Ventricle with visual assessment. To evaluate the appropriateness of the visual evaluation, two evaluators who were trained for one week were measured and the agreement between the evaluators were verified by statistical analysis. The effective doses of computed tomography were evaluated using the dose length product. As a result, there was a high correlation between the two modalities. The agreement between the two visual evaluator were also highly agreed. The mean X-ray dose of the subjects was $11.1{\pm}3.1mSv$. Although the purpose of imaging is somewhat different in the clinical setting, echocardiography could achieve the same results as radiation-invasive computed tomography. It is thought that utilization will become even larger.

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.

Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis

  • Selvaraj, Abirami;Jain, Ravindra Kumar;Nagi, Ravleen;Balasubramaniam, Arthi
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.133-140
    • /
    • 2022
  • Purpose: The aim of this review was to systematically analyze the available literature on the correlation between the gray values (GVs) of cone-beam computed tomography (CBCT) and the Hounsfield units (HUs) of computed tomography (CT) for assessing bone mineral density. Materials and Methods: A literature search was carried out in PubMed, Cochrane Library, Google Scholar, Scopus, and LILACS for studies published through September 2021. In vitro, in vivo, and animal studies that analyzed the correlations GVs of CBCT and HUs of CT were included in this review. The review was prepared according to the PRISMA checklist for systematic reviews, and the risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A quantitative analysis was performed using a fixed-effects model. Results: The literature search identified a total of 5,955 studies, of which 14 studies were included for the qualitative analysis and 2 studies for the quantitative analysis. A positive correlation was observed between the GVs of CBCT and HUs of CT. Out of the 14 studies, 100% had low risks of bias for the domains of patient selection, index test, and reference standards, while 95% of studies had a low risk of bias for the domain of flow and timing. The fixed-effects meta-analysis performed for Pearson correlation coefficients between CBCT and CT showed a moderate positive correlation (r=0.669; 95% CI, 0.388 to 0.836; P<0.05). Conclusion: The available evidence showed a positive correlation between the GVs of CBCT and HUs of CT.

Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: An in vitro study

  • Juliana Andrea Correa, Travessas;Alessandra Mendonca, dos Santos;Rodrigo Pagliarini, Buligon;Nadia Assein, Arus;Priscila Fernanda Tiecher, da Silveira;Heraldo Luis Dias, da Silveira;Mariana Boessio, Vizzotto
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.399-408
    • /
    • 2022
  • Purpose: The purpose of this study was to compare volume measurements obtained using 2 image software packages on Digital Imaging and Communications in Medicine (DICOM) images acquired from 1 multidetector computed tomography and 5 cone-beam computed tomography devices, using different protocols for physical volume measurements. Materials and Methods: Four pieces of bovine leg were prepared. Marrow was removed from 3 pieces, leaving cortical bone exposed. The resulting space of 1 piece was filled with water, another was filled with propylene glycol, and the third was left unfilled. The marrow in the fourth sample was left fully intact. Volume measurements were obtained after importing DICOM images into the Dolphin Imaging 11.95 and ITK-SNAP software programs. Data were analyzed using 3-way analysis of variance with a generalized linear model to determine the effects of voxel size, software, and content on percentage mean volume differences between tomographic protocols. A significance level of 0.05 was used. Results: The intraclass correlation coefficients for intraobserver and interobserver reliability were, respectively, 0.915 and 0.764 for the Dolphin software and 0.894 and 0.766 for the ITK-SNAP software. Three sources of statistically significant variation were identified: the interaction between software and content (P=0.001), the main effect of content (P=0.014), and the main effect of software (P=0.001). Voxel size was not associated with statistically significant differences in volume measurements. Conclusion: Both content and software influenced the accuracy of volume measurements, especially when the content had gray values similar to those of the adjacent tissues.

Can ultra-low-dose computed tomography reliably diagnose and classify maxillofacial fractures in the clinical routine?

  • Gerlig Widmann;Marcel Dangl;Elisa Lutz;Bernhard Fleckenstein;Vincent Offermanns;Eva-Maria Gassner;Wolfgang Puelacher;Lukas Salbrechter
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: Maxillofacial trauma predominantly affects young adults between 20 and 40 years of age. Although radioprotection is a legal requirement, the significant potential of dose reduction in computed tomography (CT) is still underused in the clinical routine. The objective of this study was to evaluate whether maxillofacial fractures can be reliably detected and classified using ultra-low-dose CT. Materials and Methods: CT images of 123 clinical cases with maxillofacial fractures were classified by two readers using the AOCOIAC software and compared with the corresponding results from post-treatment images. In group 1, consisting of 97 patients with isolated facial trauma, pre-treatment CT images at different dose levels (volumetric computed tomography dose index: ultra-low dose, 2.6 mGy; low dose, <10 mGy; and regular dose, <20 mGy) were compared with post-treatment cone-beam computed tomography (CBCT). In group 2, consisting of 31 patients with complex midface fractures, pre-treatment shock room CT images were compared with post-treatment CT at different dose levels or CBCT. All images were presented in random order and classified by 2 readers blinded to the clinical results. All cases with an unequal classification were re-evaluated. Results: In both groups, ultra-low-dose CT had no clinically relevant effect on fracture classification. Fourteen cases in group 2 showed minor differences in the classification code, which were no longer obvious after comparing the images directly to each other. Conclusion: Ultra-low-dose CT images allowed the correct diagnosis and classification of maxillofacial fractures. These results might lead to a substantial reconsideration of current reference dose levels.

A computed torque method incorporating an iterative learning scheme

  • Nam, Kwanghee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.1097-1112
    • /
    • 1989
  • An iterative learning control scheme is incorporated to the computed torque method as a means to enhance the accuracy and the flexibility. A learning rule is constructed by utilizing a gradient descent algorithm and data compressing techniques are illustrated. Computer simulation results show a good performance of the scheme under a relatively high speed and a heavy payload condition.

  • PDF