Abstract
The purpose of this study was evaluated the relationship between echocardiography and cardiac computed tomography in normal adults by visual assessment, and evaluated the effective doses of cardiac computed tomography. The subjects were 100 normal patients who visited two general hospitals in Chungnam, from January 1 to May 30, 2018. We obtained images by using these modalities and evaluated the wall thickness and internal dimension of the Left Ventricle with visual assessment. To evaluate the appropriateness of the visual evaluation, two evaluators who were trained for one week were measured and the agreement between the evaluators were verified by statistical analysis. The effective doses of computed tomography were evaluated using the dose length product. As a result, there was a high correlation between the two modalities. The agreement between the two visual evaluator were also highly agreed. The mean X-ray dose of the subjects was $11.1{\pm}3.1mSv$. Although the purpose of imaging is somewhat different in the clinical setting, echocardiography could achieve the same results as radiation-invasive computed tomography. It is thought that utilization will become even larger.
Keywords
Echocardiography; Computed tomography; Cardiac wall thickness; Cardiac internal dimension; X-ray dose;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lovic D, Serap E, Alp BC. How to estimate left ventricular hypertrophy in hypertensive patients. Anadolu Kardiyoloji Dergisi. 2014;14(4):389-95.   DOI
2 Choi BW, Cardiac CT, J Korean Med Assoc, 2007;50(1):5-17.   DOI
3 Kim DH, Choi SI, Chun EJ, Jang SA, Choi EG, Jang HJ, et al. Coronary CT Angiography: Focus on a New Algorithm as Diagnostic Tool in Routine Clinical Practice. J Korean Radiol Soc. 2007;56(1):461-72.   DOI
4 Higgins CB, Holt W, Pflugfelder P, Sechtem U. Functional evaluation of the heart with magnetic resonance imaging. Magnetic Resonance in Medicine. 1988;6(2):121-39.   DOI
5 Zhang S, Joseph AA, Voit D, et al. Real-time magnetic resonance imaging of cardiac function and flow-recent progress. Quantitative Imaging in Medicine and Surgery. 2014;4(5):313-29.
6 Weiger M, Pruessmann KP. Cardiac real‐time imaging using SENSE. Magnetic Resonance in Medicine. 2000;43(2):177-84.   DOI
7 Cho SH, Lee SK, Kim PK, Park JH, An CB. Fast Cardiac Magnetic Resonance Imaging Using Compressed Sensing. J The Korean Institute of Electrical Engineers. 2010;7(1):1970-71.
8 Korean Society of echocardiography. Textbook of clinical echocardiography. Edition 3rd. Seoul. Medbook; 2013:1-10.
9 Javed B, Michael D, Davindar J, Tomas N, John N, Maros F, et al. Comparison of Multidetector Computed Tomography and Two-Dimensional Transthoracic Echocardiography for Left Ventricular Assessment in Patients With Heart Failure. J American Cardiology. 2007;99(1):247-9.   DOI
10 http://www.kpanews.co.kr/article/show.asp?idx=188211&table=article&category=C
11 http://www.aftertherain.kr/medicaltoday/?work=view&idx=43476&cate=40
12 Anitha M, Prabhakar RR, Rajyalaxmi K. High resolution ultrasound imaging of cutaneous lesions. J Indian of Radiology and Imaging. 2013;23(3):269.   DOI
13 Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. European Heart Journal-Cardiovascular Imaging. 2015;16(3),233-71.   DOI
14 David S, Lubov V, Yair G, Aya A, Alicia N, Simcha RM, et al. Aortic dimensions by multi-detector computed tomography vs. echocardiography. J cardiology. 2016;67:365-70.   DOI
15 Cousin C, Miller DL, Bernardi G, Rehani MM, Schofield EV, Einstein AJ, et al. ICRP Publication 120, 2011;10:101-16.
16 Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-74.   DOI
17 Kwon SO, Dong KR, Kweon DC, Goo EH, Choi JW, Chung WK. Estimate of Radiation Doses in MDCT Using Patient Weight, PROG. MED. PHYS. 2010;21(3):246-52.
18 Abazid R, Abohamr S, Smettei OA, Qasem MS, Suresh AR, Al Barbi MF, et al. Visual versus fully automated assessment of left ventricular ejection fraction. J Avicenna of Medicine. 2018;8(2):41-5.   DOI
19 Stoodley PW, Costa RJ, Ricards DA, Thomas L. Acute myocardial infarction complicated by LV free wall rupture : benefits of echocardigraphy. J European of Echocardiography. 2007;9(1):188-9.
20 Bai AD, Steinberg M, Showler A, Burry L, Bhatia RS, Tomlinson GA, et al. Clinical Investigation: diagnostic Accuracy of Transthoracic Echocardiography for Infective Endocarditis Finding Using Transesophageal echocardiography as the Reference standard: A Meta-analysis. J American society of Echocardiography. 2017;30(7):639-46.   DOI
21 Choi JO, Shin MS, Kim MJ, Jung HO, Park JR, Sohn IS, et al. Normal Echocardiographic Measurements in a Korean Population Study: Part I. Cardiac Chamber and Great Artery Evaluation. J Cardiovasc Ultrasound. 2015;23(3):158-72.   DOI
22 Ballo H, Tarkia M, Haavisto M, Stark C, Strandberg M, Vahhsilta T, et al. Cardiovasc Ultrasound, Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pig. J Cardiovascular Ultrasound. 2017;15(1):1.   DOI
23 Kang YH, Park JS. Radiation dose and Lifetime Attributable Risk of Cancer Estimates in 64-slice Multidetector Computed Tomography. Jour. of KoCon. a. 2011;11(4):244-52.
24 Kim MC. Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography: Reduced Radiation Dose According to Varity of Examnination Protocols. J of the Korean Society of Radiological Technology. 2009;32(3):299-306.
25 Kim JS, Kim JM, Kwon SM. Basic principles of CT dose index and understanding of CT parameter for dose reduction technique. J of the Korean Society of Radiological Technology. 2015;38(1):51-61.   DOI
26 Juergens KU, Maintz D, Grude M, Boese JM, Heimes B, Fallenberg EM, et al. Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?. European radiology. 2005;15(1):111-7.   DOI
27 Yang S, Lee JS, Kim C. The Accuracy of Echocardiography and ECG in the Left Ventricular Hypertrophy. Jour. of KoCon. a. 2016;16(2):666-72.
28 Dawkins A, George N, Ganesh H, Ayoob A, Lee J, Nair R, et al. Radiologist and Sonographer Interpretation Discrepancies for Biliary Sonographic Findings. Ultrasound Q. 2017;33(4):261-4.   DOI