• 제목/요약/키워드: compressed pulse

검색결과 48건 처리시간 0.022초

가포화 자기스위치 MPC를 적용한 저온 플라즈마의 펄스에너지 전송효율 특성 (The Study on the Optimal Transmission Efficiency Characteristics of Pulse Energy Using Magnetic Pulse Compressors)

  • 이유수;정종한;정현주;김문환;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.383-387
    • /
    • 2003
  • In this paper, we have studied about optimal transmission efficiency characteristics of pulse energy in a coal plant for removing environmental polluted gas. The electrical efficiency of pulse power systems depends on impedance of the reactor. To obtain high efficiency, we used MPC(Magnetic pulse compressor) as the power switch and tested their characteristics as electrode length of the reactor and charging voltage of capacitor, As results, we obtained a compressed pulse such as pulse voltage of 10㎸, rising time 200ns and pulse width of 500ns. With increasing electrode length, the load impedance was decreased but the electrical efficiency was increased.

펄스열을 이용한 MR 영상의 Compressed Sensing 알고리즘 적용 (Pulse Sequence based MR Images for Compressed Sensing Algorithm Applications)

  • 고성민;최나래;김동현
    • 대한전자공학회논문지SP
    • /
    • 제46권5호
    • /
    • pp.1-7
    • /
    • 2009
  • 최근 Compressed Sensing (CS) 알고리즘이 다양한 분야에서 연구되고 있으며, medical imaging 분야에서도 역시 이를 이용한 연구가 활발히 진행 중이다. CS 알고리즘을 이용하기 위해서는 복원하고자 하는 신호가 sparse한 성질을 지니고 있어야 한다. 일반적으로 대부분의 의료 영상의 경우, 이러한 성질을 가지고 있지 못하기 때문에 sparsifying transform을 이용하게 된다. 하지만 MR 영상의 경우, 다른 의료 영상 modality와 비교하여 적절히 펄스열을 이용하여 영상의 contrast를 조절할 수 있다는 특징을 가지고 있다. 이에 본 논문에서는 sparsifying transform을 이용하지 않고도 펄스열에 의한 MR 영상에 CS 알고리즘을 적용할 수 있는 가능성을 제시함과 동시에 적절한 sparsifying transform을 적용하여 영상의 sparsity를 더욱 강조함으로써 CS 알고리즘의 복원 성능을 더욱 향상 시킬 수 있다는 것을 제안하고자 하며, 이를 Shepp-Logan 팬텀 영상과 in vivo 영상을 이용한 시뮬레이션을 통하여 검증하였다.

저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구 (The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma)

  • 정종한;정현주;김휘영;정용호;송금영;김근용;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

위상잡음이 레이더 시스템에 미치는 영향 분석 (Analysis of Effects of Phase Noise in Radar System)

  • 박진성
    • 한국군사과학기술학회지
    • /
    • 제16권3호
    • /
    • pp.373-381
    • /
    • 2013
  • In this paper, the effects of phase noise on the radar system were analyzed in terms of 3 point of view. The impact(s) on the compressed pulse waveform, the FMICW(Frequency Modulated Interrupted Continuous Wave) radar performance and the receiver sensitivity were investigated. From the investigation, it was indicated that the phase noise over 10 kHz offset frequency makes the side lobe level of compressed pulse worse. Also it was founded that the FMICW radar performance, especially at the noise level of range profile, is related to the phase noise. Finally, the investigation showed that the phase noise at local oscillator affects the receiver sensitivity.

유도 브릴루앙 산란에 의한 펄스 압축 과정에서의 Peak Power 반사율과 위상공액도 (Peak Power Reflectivity and Phase Conjugation Fidelity in a Pulse Compression Process by Stimulated Brillouin Scattering)

  • 조민식;최병일;남창희
    • 한국광학회지
    • /
    • 제5권1호
    • /
    • pp.37-44
    • /
    • 1994
  • 유도 브릴루앙 반사광을 고출력 레이저에 응용할 때 요구되는 반사광 특성이 실험적으로 조사되었다. 집속 렌즈의 초점거리에 따른 유도 브릴루앙 반사광의 peak power 반사율과 위상공액도가 측정되었다. 또한 반사광 가운데 펄스압축된 부분만의 위상공액도가 측정되었다. 초점거리가 긴 경우(f=100cm) 반사광의 peak power가 입사광의 약 2배에 이르렀다. 이때 반사광 중에서 압축된 선두펄스만의 위상공액도는 약 90%로 다른 시간의 펄스보다 위상공액도가 우수했다. 공간적으로는 유도 브릴루앙 이득이 가장 큰 광축부분의 바사관이 최대의 펄스압축, peak power 반사율, 위상공액도를 보여서 유도 브릴루앙 산란을 응용할 때 가장 유용한 부분으로 확인되었다.

  • PDF

엑사이머 레이저 여기용 고반복 펄스압축 시스템 개발에 관한 연구 (Development of multi-repetitive Pulse Compression System for excimer laser excitation)

  • 전상영
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.36-38
    • /
    • 1989
  • We have developed Magnetic Pulse Compression System to realize repetitive excimer laser excitation. The principle of this system is to use the large change in permiability owing to the nolinear characteristics of ferro-magnetic material (Metglas2605s-2 metal ribon). Prior to the laser operation, the MPC system was tested with a dummy load (5$\Omega$) and laser head. Laser head has a discharge volume of 1.0 (w) x 2.0 (h) x 20.0(1) cm. This MPC system compressed a 6.2us (FWHM), 80 A pulse into a 0.4us(FWHM), 1.3kA pulse.

  • PDF

금속 증기 레이저용 펄스 전원 장치 (A Pulse Power Supply for Metal Vapor Lasers)

  • 차병헌;이흥호;진정태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.190-197
    • /
    • 2005
  • A reliable and compact pulse power supply using a thyratron and a magnetic pulse compression (MPC) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a conventional thyratron-discharge type pulse power supply. A thyratron generated a long pulse of its conduction pulse width 500 ns and then it was compressed to less than 80 ns of its output voltage rise time by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 30 mm inner diameter and 1.5 m discharge length. It was operated several hundreds hours without any troubles.

IGBT를 사용한 금속증기레이저용 펄스 전원 (A Pulse Power Supply for a Metal Vapor Laser Using IGBTs)

  • 진정태;차병헌;김철중;이흥호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권8호
    • /
    • pp.415-419
    • /
    • 2004
  • A pulse power supply using IGBTs and MPC (magnetic pulse compression) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a vacuum tube or thyratron type pulse power supply. A series-connected IGBT array generated a long pulse of its pulse width 2 ${\mu}\textrm{s}$ md then it was compressed to less than 100 ns by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 10 mm inner diameter and 0.5 m discharge length. and successfully operated.

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법의 실험적 고찰 (Experimental Study of Second Harmonic Ultrasound imaging with a Weighted Chirp Signal)

  • 김동열;이종철;송태경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.151-154
    • /
    • 2001
  • In this Paper, a new harmonic imaging technique is proposed and evaluated experimentally. In the proposed method, a weighted chin signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic (2f0) component of a transmitted chirp signal generated in a square-law system. The proposed method uses the compressed 2f0 component to form an image, for which the crosscorrelation term with f0 component should be suppressed below at least -60dB. After experiment, the 6dB pulse width and peak sidelobe level of the compressed 2f0 component were 0.7us and -60dB, respectively. This result shows that the proposed method can successfully eliminate the f0 component with a single transmit-receive event and therefore is more efficient than the conventional pulse inversion (PI) method in terms of frame rate. We also observed that the 2nd harmonic compont starts to decrease for source pressure higher than 210kPa in water, which implies that SNR of the 2nd harmonic imaging using short pulses cnanot be incresed beyond a certain limit.

  • PDF

광섬유와 회절격자를 이용한 1.319$\mu\textrm{m}$파장 광펄스의 압축과 솔리톤 효과에 의한 재압축 (Optical pulse compression at 1.319$\mu\textrm{m}$ through fiber-grating pair and further compression using soliton effects)

  • 이재승
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 제6회 파동 및 레이저 학술발표회 Prodeedings of 6th Conference on Waves and Lasers
    • /
    • pp.102-108
    • /
    • 1991
  • Utilizing self-phase modulation effects of a dispersion-shifted fiber and delay-line characteristics of two gratings, mode-locked 80 ps pulses at 1.319${\mu}{\textrm}{m}$ wavelength from a Nd: YAG laser are compressed down to 2.1 ps. These pulses are further compressed down to 340 fs using higher order soliton effects in a common single mode fiber.

  • PDF