• Title/Summary/Keyword: composite sections

Search Result 516, Processing Time 0.027 seconds

Biological stability of Zirconia/Alumina composite ceramic Implant abutment (지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구)

  • Bae, Kyu-Hyun;Han, Jung-Suk.;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.

A Study on the Development of Ultra-precision Small Angle Spindle for Curved Processing of Special Shape Pocket in the Fourth Industrial Revolution of Machine Tools (공작기계의 4차 산업혁명에서 특수한 형상 포켓 곡면가공을 위한 초정밀 소형 앵글 스핀들 개발에 관한 연구)

  • Lee Ji Woong
    • Journal of Practical Engineering Education
    • /
    • v.15 no.1
    • /
    • pp.119-126
    • /
    • 2023
  • Today, in order to improve fuel efficiency and dynamic behavior of automobiles, an era of light weight and simplification of automobile parts is being formed. In order to simplify and design and manufacture the shape of the product, various components are integrated. For example, in order to commercialize three products into one product, product processing is occurring to a very narrow area. In the case of existing parts, precision die casting or casting production is used for processing convenience, and the multi-piece method requires a lot of processes and reduces the precision and strength of the parts. It is very advantageous to manufacture integrally to simplify the processing air and secure the strength of the parts, but if a deep and narrow pocket part needs to be processed, it cannot be processed with the equipment's own spindle. To solve a problem, research on cutting processing is being actively conducted, and multi-axis composite processing technology not only solves this problem. It has many advantages, such as being able to cut into composite shapes that have been difficult to flexibly cut through various processes with one machine tool so far. However, the reality is that expensive equipment increases manufacturing costs and lacks engineers who can operate the machine. In the five-axis cutting processing machine, when producing products with deep and narrow sections, the cycle time increases in product production due to the indirectness of tools, and many problems occur in processing. Therefore, dedicated machine tools and multi-axis composite machines should be used. Alternatively, an angle spindle may be used as a special tool capable of multi-axis composite machining of five or more axes in a three-axis machining center. Various and continuous studies are needed in areas such as processing vibration absorption, low heat generation and operational stability, excellent dimensional stability, and strength securing by using the angle spindle.

HYDROLYTIC DEGRADATION OF POSTERIOR RESIN RESTORATIVE MATERIALS (구치부 레진 수복 재료의 가수분해)

  • Yang, Kuy-Ho;Park, Mi-Ran;Choi, Nam-Ki;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.673-682
    • /
    • 2001
  • The use of resin composites has continued to increase over the last several years. In spite of their growing popularity, composites continue to exhibit a number of undesirable characteristics. One of the major deficiencies of composite restorative resins is their inadequate resistance to wear. Of the multitude of factors that have been associated with wear, subsurface degradation within the restoration is considered to be one. The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. This solution with a high concentration of hydroxyl ions is a convenient medium for accelerated degradation of silane coupling and filler particles. The brands studies were Definite($Degussa-H\ddot{u}ls$ AG, Germany), Prodigy(Kerr, USA), Pyramid(Bisco, USA) and Synergy(Coltene, Swiss). Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters : (a) mass loss(%)-determined from pre-and post-exposed specimen weights : (b) Si loss(ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation $depth({\mu}m)$-measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. Mass loss of Synergy was $1.24{\pm}0.002%$, it was the highest, there was no significant difference among the materials. 2. The degree of degradation layer depth of Synergy was $107.83{\pm}2.52{\mu}m$, it was the highest, there was no significant difference among any other materials than Synergy. 3. There was no difference among the four materials in Si loss. 4. The correlation coefficient between mass loss and degradation depth was relatively high(r=0.06, p<0.05). 5. There was no coefficient correlation between Si loss and mass loss, the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler.

  • PDF

Difference of Somatic Symptoms between Anxiety Disorder and Major Depressive Disorder and Their Domainal Association with Suicidal Idealization, Plan and Attempts (불안 장애와 주요우울장애에서 나타나는 신체 증상과 증상군에 따른 자살 사고, 계획, 행동과의 관계 고찰)

  • Ahn, Jun Seok;Kim, Eun young;Cho, Maeng Je;Hong, Jin Pyo;Hahm, Bong-Jin;Chung, In-Won;Ahn, Joon-Ho;Jeon, Hong Jin;Seong, Su Jeong;Lee, Dong-Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.2
    • /
    • pp.174-183
    • /
    • 2016
  • Objectives : The aim of this study is to evaluate difference of somatic symptoms of anxiety disorder and major depressive disorder and domainal association with suicidal idealization, plan, and attempts. Methods : A total of 359 adults diagnosed with major depressive disorder and anxiety disorder of last one year participated. Participants interviewed with certain sections of Korean version of Composite International Diagnostic interview of CIDI. Sections of interests includes questionnaires regarding somatic symptoms and suicidal idea, plan and attempts of last one year. Results : Chest pain shows more prevalence in major depressive disorder. Symptoms of Headache and loose stool are more prevalent in anxiety disorder. Difficulty in equilibrium and fainting spells are more common somatic complaints of co-diagnosis states of anxiety disorder and major depressive disorder. Comparing 3 domains of pain symptoms, gastrointestinal symptoms and pseudo-neurological symptoms, pain symptom domains, gastrointestinal symptoms domain shows significant statistic difference between diagnosis. Average somatic symptom numbers of each symptom domains increase through suicidal idealization, plan and attempt, accordingly. Conclusions : Our finding shows some of somatic symptoms are more prevalent at certain diagnosis. Since increasing numbers of somatic complaints of each symptom domains goes with the suicidal idealization to suicidal attempts, proper psychiatric evaluation and consultations are crucial for patients with numerous somatic complaints in non-psychiatric clinical settings.

Investigation of Minimum Number of Drop Levels and Test Points for FWD Network-Level Testing Protocol in Iowa Department of Transportation (아이오와 주 교통국의 FWD 네트워크 레벨 조사 프로토콜을 위한 최소 하중 재하 수와 조사지점 수의 결정)

  • Kim, Yong-Joo;Lee, Ho-Sin(David);Omundson, Jason S.
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.39-46
    • /
    • 2010
  • In 2007, Iowa department of transportation (DOT) initiated to run the falling weight deflectometer (FWD) network-level testing along Iowa highway and road systems and to build a comprehensive database of deflection data and subsequent structural analysis, which are used for detecting pavement structure failure, estimating expected life, and calculating overlay requirements over a desired design life. Iowa's current FWD networklevel testing protocol requires that pavements are tested at three-drop level with 8-deflection basin collected at each drop level. The test point is determined by the length of the tested pavement section. However, the current FWD network-level program could cover about 20% of Iowa's highway and road systems annually. Therefore, the current FWD network-level test protocol should be simplified to test more than 20% of Iowa's highway and road systems for the network-level test annually. The main objective of this research is to investigate if the minimum number of drop levels and test points could be reduced to increase the testing production rate and reduce the cost of testing and traffic control without sacrificing the quality of the FWD data. Based upon the limited FWD network-level test data of eighty-three composite pavement sections, there was no significant difference between the mean values of three different response parameters when the number of drop levels and test points were reduced from the current FWD network-level testing protocol. As a result, the production rate of FWD tests would increase and the cost of testing and traffic control would be decreased without sacrificing the quality of the FWD data.

Analysis of Buckling Causes and Establishment of Reinforcement Method for Support of Plate Girder Bridge (플레이트 거더교 지점부의 좌굴발생 원인분석 및 보강방안 수립)

  • Ok, Jae-Ho;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.520-526
    • /
    • 2019
  • I-type girders are widely applied as very economical sections in plate girder bridges. There has been research on developing composite laminated panels, curved plates reinforced with closed-end ribs, and new forms of ribs and compression flanges for steel box girders. However, there is a limitation in analyzing the exact cause of local buckling caused by an I-type girder's webs. Therefore, an I-type girder's web was modeled using the finite element analysis program LUSAS 17.0 before and after reinforcement. We checked for the minimum thickness criteria presented in the Korea highway bridge design code, and the cause of buckling after performing a linear elastic buckling analysis of dead and live loads was analyzed. Before reinforcement, an eigenvalue (λ1) at the 1st mode was 0.7025, the critical buckling load was smaller than the applied load, and there is a buckling. After reinforcement, when applying vertical and horizontal stiffeners to the web part of the girder at support, a Nodal line was formed, the eigenvalue was 1.5272, and buckling stability was secured. To improve buckling trace of the girder at the support, an additional plate was applied to the web at the support to ensure visual and structural safety, but buckling occurs at center of web. The eigenvalue (λ1) was 3.5299, and this method is efficient for reinforcing the web of the support.

Experimental Study for the Bending Behavior of Precast Concrete Panel and Composite Deck for Railway Bridge (철도교 바닥판용 프리캐스트 패널과 합성 바닥판의 휨거동에 대한 실험적 연구)

  • Seol, Dae-Ho;Lee, Kyoung-Chan;Youn, Seok-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.21-31
    • /
    • 2018
  • This paper presents an experimental investigation on the structural performance of precast ribbed panel specimens and bridge deck specimens fabricated from the panels. The panel specimens are developed for permanent deck forms of railway bridges (PSC girder). The decks of railway bridges have short lengths compared with highway bridges. Therefore, precast panels for railway bridges are different from those of highway bridges. The precast panels have ribs designed for crack control at the bottom of the sections. Two kinds of specimens were examined: one with 400-mm width and one with 1200-mm width. Three specimens of each type were fabricated, and a total of 12 specimens were tested. In this test, the ultimate load, strain of the reinforcement and concrete, crack width, deformation, and slip were measured. The structural performance of the specimens was assessed using the Korea railway bridge design code and Eurocode. All specimens met the current design criteria for structural strength and serviceability.

LRFD Design and Reliability Level Estimation of a Steel Closed-Box Girder Bridge (폐단면 강박스거더교의 LRFD 설계와 신뢰성수준 평가)

  • Huh, Jung-Won;Yun, Dong-Geon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.217-225
    • /
    • 2010
  • Most of the steel bridges in Korea are being currently designed by the allowable stress design method that uses the conventional deterministic factors of safety. However the limit state design based on the concept of probability, statistics and reliability engineering is becoming very popular as a global standard deign method, leading the rational and economic bridge design. As part of the fundamental research to establish the load and resistance factor design(LRFD) of steel bridges considering domestic environmental conditions and regional characteristics, an experimental design is conducted by applying AASHTO-LRFD specification especially to a steel closed-box girder, which occupies relatively a large portion of steel bridges in Korea. Throughout the experimental design according to various sectional changes, some of the issues to be considered in the LRFD design of a composite steel closed-box girder bridge are examined. In this process, an Excel-based design verification program is developed for easy computation and prevention of errors. Quantitative reliability levels of the bridge sections designed by LRFD are also estimated using a reliability analysis method, and compared with the target reliability indexes applied in the LRFD design to verify the validity of the procedure and methodology used in this study.

Analysis of Korea Earth Science Olympiad Items for the Enhancement of Item Quality (한국 지구과학 올림피아드 문항 분석을 통한 문항의 질 향상 방안)

  • Lee Ki-Young;Kim Chan-Jong
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.511-523
    • /
    • 2005
  • The purpose of this study is to analyze the 1st and 2nd Korea Earth Science Olympiad (KESO) items, in order to find informations to enhance item quality. To do this, internal and external item classification frameworks are developed. Item difficulty (P), discrimination index (DI), correlation, and reliability are estimated by using classical test theory. Generalizability is also estimated by applying the generalizability theory. The results of item classification are as follows: (1) ‘Geology’, ‘astronomy’ and ‘data analysis and interpretation’ are dominant in content and inquiry process domain, respectively. Nearly every item has textbook context. (2) There is no difference between the preliminary and final tests in terms of their thinking skills sections. (3) As a whole, the ratio of items with pictures is high in item representation. However, multiple-choice and short answer items are more common in preliminary competition, and essay type items are found more often in final competition. The ratio of simple items is high in middle school section and preliminary competition, but composite items are dominant in high school section and final competition. The findings of item analysis are as follows: (1) In the middle school section, P is low and DI is moderate. But in the high school section, there is a considerable differences between science high schools and other high schools in general. (2) The highest correlation is reported between the scores of meteorology domain and total score in middle school, whereas in high school astronomy domain and total score show the highest correlation. (3) General high school section show the highest Cronbach $\alpha$ and generalizability. (4) General high school section show acceptable generalizability coefficient (> 0.80), but middle and science high school section should increase the number of items to reach acceptable generalizability level.

Microleakage and Anticariogenic Effect of S-PRG Filler-containing Pit and Fissure Sealant (S-PRG filler를 함유한 치면열구전색제의 미세누출 및 항우식효과)

  • Shin, Seungwoo;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Pit and fissure sealant prevents biofilm accumulation, plays a role in forming a barrier to acidic substance made by the bacteria. The Surface reaction-type pre-reacted glass ionomerI(S-PRG) filler was developed in 1999. S-PRG filler releases fluoride continuously and does not decompose under wet conditions. The aim of this study was to test the microleakage and anticariogenic effect to adjacent enamel of S-PRG filler-containing pit and fissure sealant. Sound premolars and molars were used in this study. A S-PRG filler-containing pit and fissure sealant, Beautisealant$^{(R)}$(Shofu, Japan) was used for this experiment, the composite resin sealant Concise$^{(R)}$(3M ESPE, USA) was used as control. For the microleakage test, all teeth surface were double coated with finger nail varnish, with the exception of a 1.0 mm window around the restoration margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in tap water. For the anticariogenic effect evaluation, all tooth were immersed in artificial carious solution for 9 days and rinsed with tap water. Each tooth was embedded in orthodontic acrylic rein and subsequently sectioned longitudinally in a bucco-lingual direction with a low-speed diamond saw. The cut sections were examined using a stereomicroscope. Differences in microleakage between the two groups were not different significantly. But the S-PRG filler-containing pit and fissure sealant showed higher anticariogenic effect than that of flowable resin sealant.