• 제목/요약/키워드: composite insulation system

검색결과 69건 처리시간 0.024초

액체$N_2$중 절연재료의 부분방전 열화 연구 (Study of Partial Discharge Degradation of Insulating Materials in Liquid Nitrogen)

  • 김현희;김상현;마대영;장종근;남궁도;조전욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.406-410
    • /
    • 1995
  • A superconducting cable is one of the promising methods of undground transmission of high electric power in the future. It is very important that composite insulation system of $LN_2$ and polymer films takes into consideration for application high $T_c$ superconductor. This study is about both the partial discharge and properties V-t in $LN_2$. As result, applied voltage doesn't depend on the radius of non-eroded area but eroded area. And eroded area is observed the formation such as the ring of a tree.

  • PDF

플라즈마 표면개질에 따른 FRP의 자외선 열화 특성에 관한 연구 (A Study on the UV Degradation Characteristics of FRP by Plasma Surface Modification)

  • 황명환;임경범
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권3호
    • /
    • pp.122-126
    • /
    • 2006
  • In this study, composite materials were put to dry interfacial treatment by use of plasma technology It has been presented that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 Torr of system pressure, 100 W of discharge power, and 3 minutes of discharge time. The decrease in surface potential of charged samples by corona discharge indicates that the amount of accumulated electrical charges reduces and the charges that have been injected lessen rapidly when the duration of UV irradiation increases. The surface resistivity and the tensile strength of plasma treated samples, a longer UV irradiation time resulted in decreased insulation.

발전기 고정자 권선에 사용되는 절연재료의 기계적 및 전기적 특성 (Mechanical and Electrical Properties of Insulation System used in Generator Stator Windings)

  • 김희동;박종정;김희곤;강도열;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1376-1378
    • /
    • 1997
  • Mechanical and electrical properties of mica/epoxy composite materials were investigated by dynamic mechanical analyzer(DMA) and dielectric analysis (DMA). Both modulus and permittivity of sound specimens were higher than those of aged specimens. Two results show that $tan{\delta}$ of sound specimens is lower than that of aged specimens. DMA results showed that glass transition temperatures of sound and aged specimens are observed to be $87.16^{\circ}C$ and $88.38^{\circ}C$, which increases with the increase of aging time.

  • PDF

플라즈마 표면개질에 따른 FRP의 자외선 열화 특성에 관한 연구 (A Study on the UV Degradation characteristics of FRP by Plasma Surface Modification)

  • 임경범;이상희;유도현;황명환;임응춘;조기선;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1544-1546
    • /
    • 2003
  • In this study, composite materials were put to dry interfacial treatment by use of plasma technology. It has been presented that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 torr of system Pressure, 100 W of discharge power, and 3 minutes of discharge time. The decrease in surface potential of charged samples by corona discharge indicates that the amount of accumulated electrical charges reduces and the charges that have been injected lessen rapidly when the duration of UV irradiation increases. The surface resistivity and the tensile strength of plasma treated samples, a longer UV irradiation time resulted in decreased insulation.

  • PDF

액체질소 중에서 spacer의 부분적 침적에 대한 연면 방전특성 (Characteristics of Surface Flashover on Partially Immersed of Spacer in Liquid Nitrogen)

  • 김영석;이병성;백승명;정종만;정순용;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제13권2호
    • /
    • pp.177-182
    • /
    • 2000
  • Composite insulation system of liquid nitrogen and solid spacer is widely applied in high temperature superconduction power machine. This study has three step procedure. As follow, first step is composition of parallel deposited electrode and vertically deposited electrode along the direction of immersion in liquid nitrogen(LN2). Second step is investigation into surface flashover voltage of solid spacer under partially immersed in LN2, and last step is comparison the result of this research with that of fully immersed in LN2 and at cryogenic temperature gaseous nitrogen(GN2). This result presented that surface flashover voltage along solid spacer half immersed in LN2 was almost the same as that of fully immersed spacer when the thickness of spacer(t) was t<10mm. In the case of t> 10mm, however, spacer flashover voltage was equal to that obtained in GN2 at cryogenic temperature. And the immersed direction functions as role of deciding the difference of surface flashover voltage.

  • PDF

Creepage Distance Measurement Using Binocular Stereo Vision on Hot-line for High Voltage Insulator

  • He, Wenjun;Wang, Jiake;Fu, Yuegang
    • Current Optics and Photonics
    • /
    • 제2권4호
    • /
    • pp.348-355
    • /
    • 2018
  • How to measure the creepage distance of an insulator quickly and accurately is a problem for the power industry at present, and the noticeable concern is that the high voltage insulation equipment cannot be measured online in the charged state. In view of this situation, we develop an on-line measurement system of creepage distance for high voltage insulators based on binocular stereo vision. We have proposed a method of generating linear structured light using a conical off-axis mirror. The feasibility and effect of two ways to solve the interference problem of strong sunlight have been discussed, one way is to use bandpass filters to enhance the contrast ratio of linear structured light in the images, and the other way is to process the images with adaptive threshold segmentation and feature point extraction. After the system is calibrated, we tested the measurement error of the on-line measurement system with a composite insulator sample. Experimental results show that the maximum relative error is 1.45% and the average relative error is 0.69%, which satisfies the task requirement of not more than 5% of the maximum relative error.

노즈 페어링 구조용 복합재 평판의 음향 하중 저감 특성 (Acoustic Loads Reduction of Composite Plates for Nose Fairing Structure)

  • 박순홍;공철원;장영순;이영무
    • Composites Research
    • /
    • 제17권3호
    • /
    • pp.15-22
    • /
    • 2004
  • 위성 발사체의 추진 기관에 의한 음향 하중은 이륙 시 작용하는 주요한 동적 하중 중 하나로서, 이에 의한 위성이나 탑재물의 파손이 보고되고 있다. 위성이나 탑재물에 작용하는 음향 하중의 강토를 저감하기 위해서는 노즈 페어링의 구조 설계 시 차음 성능을 고려한 설계가 필요하다. 특히 복합재 구조의 경우 금속재 구조에 비해 비강성이 커서 음향 하중의 차음 측면에서는 불리하다. 본 논문에서는 위성 발사체의 노즈 페어링용 복합재 평판의 차음 특성을 살펴보았다. 노즈 페어링 구조로 사용 가능한 4종의 복합재 구조에 대하여 무한판 이론 및 통계적 에너지 해석법(SEA)을 이용하여 차음 성능을 평가하였다. 해석 결과를 토대로 두 종류의 복합재 평판을 제작하여 이에 대한 차음 성능을 측정하고 예측치와 비교를 수행하였다. 이를 바탕으로 무게 대비 차음 성능이 우수한 노즈 페어링용 복합재 구조를 선정할 수 있었다.

복합자재의 패널 간 화염확산방지에 따른 플래시오버 지연 효과에 대한 실험적 연구 (Experimental Study on the Flash Over Delay Effects according to the Prevention of Flame Spread between Composite Material Panels)

  • 김도현;조남욱
    • 한국화재소방학회논문지
    • /
    • 제31권2호
    • /
    • pp.1-8
    • /
    • 2017
  • 샌드위치패널은 건축물의 내 외벽 및 지붕구조에 사용되며 양면의 불연성재료와 단열용 심재로 구성된 복합자재이다. 뛰어난 단열성능과 경량 및 시공의 우수한 특성 대비 화재 시 패널간 결합부위를 통해 화염이 내부로 유입되어 심재가 쉽게 용융되며 급격한 화염확산으로 인명 및 재산피해를 발생시킨다. 현행 건축법은 건축물 마감재료에 대하여 소규모 시험편에 대한 화재시험방법으로 연소성능을 파악하며 규정한 성능기준에 합격한 제품을 사용하도록 한다. 외벽 마감재료의 경우 불연 준불연 성능확보 재료를 사용하거나 화재확산방지구조를 설치하도록 규정한다. 본 연구는 외벽 마감재료에 국한되어 적용하고 있는 화재확산방지 구조를 샌드위치패널 건축물에 적용하여 수평 수직 화재확산의 위험성의 차이를 확인하고자 하였다. 이에 샌드위치패널에 대하여 ISO 13784-1 시험방법을 통한 실물화재실험과 금속구조물을 이용하여 패널간 화염확산을 차단하는 시공을 통해 화염확산방지 적용 여부에 대한 연소거동과 그 효과를 측정하였다. 실험 결과 패널 조인트 부위의 화염확산방지구조 시공은 패널 내부의 화염확산을 지연하며 이에 따른 플래시오버 시간이 지연되어 복합자재 건축물의 화재안전확보에 중요한 요인으로 작용될 수 있음을 확인하였다.

Salt fog 시험에서 인가전계에 따른 silicone rubber의 방전전류의 특성 (Properties of Discharge Current on Silicone Rubber as Electrical Field in Salt Fog)

  • 강성화;박영국;이운용;이광우;장동욱;김완수;이용희;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1621-1623
    • /
    • 1999
  • Recently, high voltage outdoor ploymer insulators have been widely used commercially owing to their excellent electrical and mechanical properties, superior comtamination flashover performance, light weight, easy installation or handing, no maintenance during service, competitive price and so on. compared to porcelaain and glass insulators. For instance, silicone rubber(SR) for polymeric insulators specially has much superior insulating and anti-pollution performance due to its specific hydrophobicity even in severe contaminated environments. We have investigated surface discharge current characteristics of silicone rubbers(SR) for HV outdoor composite insulation specimen under accelerated aging codition using a computer measuring system. The relations of average leakage current and surface discharge current repetition rates and discharge current amplitude, the distribution of discharge current amplitude were studied to investigate electrical conduction of silicone rubber surface with the salt fog condition.

  • PDF

VLS growth of ZrO2 nanowhiskers using CVD method

  • 백민기;박시정;정진환;최두진
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.149-149
    • /
    • 2016
  • Ceramic is widely known material due to its outstanding mechanical property. Besides, Zirconia(ZrO2) has a low thermal conductivity so it is advantage in a heat insulation. Because of these superior properties, ZrO2 is attracted to many fields using ultra high temperature for example vehicle engines, aerospace industry, turbine, nuclear system and so on. However brittle fracture is a disadvantage of the ZrO2. In order to overcome this problem, we can make the ceramic materials to the forms of ceramic nanoparticles, ceramic nanowhiskers and these forms can be used to an agent of composite materials. In this work, we selected Au catalyzed Vapor-Liquid-Solid mechanism to synthesize ZrO2 nanowhiskers. The ZrO2 whiskers are grown through Hot-wall Chemical Vapor Deposition(Hot wall CVD) using ZrCl4 as a powder source and Au film as a catalyst. This Hot wall CVD method is known to comparatively cost effective. The synthesis condition is a temperature of $1100^{\circ}C$, a pressure of 760torr(1atm) and carrier gas(Ar) flow of 500sccm. To observe the morphology of ZrO2 scanning electron microscopy is used and to identify the crystal structure x-ray diffraction is used.

  • PDF