• Title/Summary/Keyword: complex motion

Search Result 814, Processing Time 0.027 seconds

Numerical Analysis of Simultaneous Cooling Process of Upper and Lower Side of Running Hot Steel Strip (주행하는 고온 강재의 상하부 동시 냉각 과정 수치해석)

  • Kwon, Myeon Jae;Park, Il Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1051-1056
    • /
    • 2014
  • After hot rolling, a high-temperature steel plate with a temperature higher than $800^{\circ}C$ is rapidly cooled by multiple circular water jets. In this cooling process, because the temperature of the steel plate is much higher than the boiling point of the cooling water, film-boiling heat transfer occurs and a very thin steam layer forms between the plate surface and the cooling water. The steam layer acts as a thermal resistance that prevents heat transfer between the cooling water and the steel plate. In addition to the film-boiling heat transfer, complex physical phenomena such as the free-surface flow of residual water that accumulated on the material and the material's high-speed motion also occur in the cooling process. In this study, the simultaneous cooling process of the upper and lower sides of a running hot steel strip is investigated using a three-dimensional numerical model and the cooling performances and characteristics of the upper-side cooling and lower-side cooling are compared.

Latissimus Dorsi Transfer in Brachial Plexus Injury for the Elbow Flexion (상완 신경총 손상후 주관절 근력 회복을 위한 광배근 전이술)

  • Han, Chung-Soo;Chung, Duke-Whan;Soh, Jae-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1998
  • The incidence of brachial plexus injury is increasing because of the development of motor vehicle but the the results of treatment was reported poor due to its complex anatomical structure and changes of function and sensory during the recovery after trauma. But the results of treatment has been improved by the recently introduced high sensitive diagnostic method that can evaluate accurately the site and extent of the injury and treatment method. Restoration of the elbow flexion is the most important goal of treatment after brachial plexus injury and nerve graft, neurotization and muscle transfer were used for methods of treatment. From December 1992 to May 1994, the author performed 6 cases of latissimus dorsi transfer at the same side for the improvement of elbow flexion in the patients of brachial plexus injury. There were 5 cases of male, one case of female and average age was 22 years old. The causes of injury were traffic accident in 3 cases, gun shot injury, falldown and birth injury in each one case and in all cases, the type of injury were upper arm type. The average follow up period were 1 year 5 months ranging from 12 months to 4 years 5 months. In all cases, active elbow flexion was impossible before operation and average muscle power was grade I. We analysed the active range of motion, muscle power and the functional results. At the last follow up, range of active elbow flexion was average $124^{\circ}$ and flexion contracture was average 11 degrees and the average of muscle power was grade IV. In the functional analysis, there were two cases of excellent, three cases of good and 1 case of fair. There was no complications including wound infection, vascular compromise and donor site problem. The results of latissimus dorsi transfer for improvement elbow flexion in the patients of brachial plexus injury is one of the useful mettled for the restoration of elbow flexion.

  • PDF

Cloth Modeling using Implicit Constraint Enforcement (묵시적 제한방법을 이용한 옷 모델링 방법)

  • Hong, Min;Lee, Seung-Hyun;Park, Doo-Soon
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.4
    • /
    • pp.516-524
    • /
    • 2008
  • This paper presents a new modeling technique for the simulation of cloth specific characteristics with a set of hard constraints using an implicit constraint enforcement scheme. A conventional explicit Baumgarte constraint stabilization method has several defects. It requires users to pick problem-dependent coefficients to achieve fast convergence and has inherent stabilization limits. The proposed implicit constraint enforcement method is stable with large time steps, does not require problem dependent feed-back parameters, and guarantees the natural physics-based motion of an object. In addition, its computational complexity is the same as the explicit Baumgarte method. This paper describes a formulation of implicit constraint enforcement and provides a constraint error analysis. The modeling technique for complex components of cloth such as seams, buttons, sharp creases, wrinkles, and prevention of excessive elongation are explained. Combined with an adaptive constraint activation scheme, the results using the proposed method show the substantial enhancement of the realism of cloth simulations with a corresponding savings in computational cost.

  • PDF

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

Ligamentoplasty with interposition of the proximal interphalangeal joint in the treatment of unicondylar osteochondral defects: a cadaveric feasibility study

  • Hery, Jean-Charles;Picart, Baptiste;Malherbe, Melanie;Hulet, Christophe;Lombard, Aude
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.635-640
    • /
    • 2021
  • Background Injuries to the proximal interphalangeal (PIP) joint are common and complex. However, the treatment of osteochondral defects of the head of the proximal phalanx has rarely been described. Herein, we propose a new technique for the management of unicondylar defects of the proximal phalanx that can restore joint amplitudes and provide PIP stability. Methods In this cadaveric feasibility study, unicondylar defects were generated using striking wedges and chisels. First, a transverse tunnel measuring 2 mm in diameter passing through the head of the proximal phalanx was made. A second tunnel at the base of the middle phalanx with the same diameter was then created. The hemitendon of the flexor carpi radialis graft was passed through each of these tunnels. The proximal end of the graft was interposed in the area with a loss of bone substance. The ligamentoplasty was then tensed and fixed by two anchors on the proximal phalanx. Joint amplitudes and frontal stability were measured preoperatively and postoperatively. Results There was no significant change in the joint's range of motion: preoperatively, the mean mobility arcs were -2° to 113.80°, and they were -2° to 110° after the procedure (P=0.999). There was no significant difference in joint stability (P>0.05). Conclusions Ligamentoplasty with PIP interposition appears to be a possible solution for the management of unicondylar defects of the proximal phalanx. An evaluation of clinical results is planned in order to definitively confirm the validity of this procedure.

Shoulder Arthrokinematics of Collegiate Ice Hockey Athletes Based on the 3D-2D Model Registration Technique

  • Jeong, Hee Seong;Song, Junbom;Lee, Inje;Kim, Doosup;Lee, Sae Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.155-161
    • /
    • 2021
  • Objective: There is a lack of studies using the 3D-2D image registration techniques on the mechanism of a shoulder injury for ice hockey players. This study aimed to analyze in vivo 3D glenohumeral joint arthrokinematics in collegiate ice hockey athletes and compare shoulder scaption with or without a hockey stick using the 3D-2D image registration technique. Method: We recruited 12 male elite ice hockey players (age, 19.88 ± 0.65 years). For arthrokinematic analysis of the common shoulder abduction movements of the injury pathogenesis of ice hockey players, participants abducted their dominant arm along the scapular plane and then grabbed a stick using the same motion under C-arm fluoroscopy with 16 frames per second. Computed tomography (CT) scans of the shoulder complex were obtained with a 0.6-mm slice pitch. Data from the humerus translation distances, scapula upward rotation, anterior-posterior tilt, internal to external rotation angles, and scapulohumeral rhythm (SHR) ratio on glenohumeral (GH) joint kinematics were outputted using a MATLAB customized code. Results: The humeral translation in the stick hand compared to the bare hand moved more anterior and more superior until the abduction angle reached 40°. When the GH joint in the stick hand was at the maximal abduction of the scapula, the scapula was externally rotated 2~5° relative to 0°. The SHR ratio relative to the abduction along the scapular plane at 40° indicated a statistically significant difference between the two groups (p < 0.05). Conclusion: With arm loading with the stick, the humeral and scapular kinematics showed a significant correlation in the initial section of the SHR. Although these correlations might be difficult in clinical settings, ice hockey athletes can lead to the movement difference of the scapulohumeral joints with inherent instability.

Comminuted Radial Head Fracture in All-arthroscopic Repair of Elbow Fracture-dislocation: Is Partial Excision of the Radial Head an Acceptable Treatment Option?

  • Yang, Hee Seok;Kim, Jeong Woo;Lee, Sung Hyun;Yoo, Byung Min
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.234-239
    • /
    • 2018
  • Background: In elbow fracture-dislocation, partial excision of the comminuted radial head fracture that is not amenable to fixation remains controversial considering the accompanying symptoms. This study was undertaken to evaluate the results of radial head partial excision when the comminuted radial head fracture involved <50% of the articular surface in all-arthroscopic repair of elbow fracture-dislocation. Methods: Patients were divided into two groups based on the condition of the radial head fracture. In Group A, the patients had a radial head comminuted fracture involving <50% of the articular surface, and underwent arthroscopic partial excision. Group B was the non-excision group comprising patients with stable and non-displacement fractures. Follow-up consultations were conducted at 6 weeks and at 3, 6, 12, and 24 months after surgery. Results: In all, 19 patients (Group A: 11; Group B: 8) met the inclusion criteria and were enrolled in the study. At the final follow-up, all 19 patients showed complete resolution of elbow instability. No significant differences were observed in the range of motion, visual analogue scale score, and Mayo elbow performance score between groups. Radiological findings did not show any complications of the radiocapitellar joint. However, nonunion of the coracoid fracture was observed in 3 patients (Group A: 1; Group B: 2), without any accompanying instability and clinical symptoms. Conclusions: Considering that the final outcome is coronoid fracture fixation and lateral collateral ligament complex repair for restoring elbow stability, arthroscopic partial excision for radial head comminuted fractures involving <50% of articular surface is an effective and acceptable treatment for elbow fracture-dislocation.

Fabrication of Fluorescent Labeled Bi-compartmental Particles via the Micromolding Method (미세 성형 방법을 이용한 형광 표지된 이중 분획 입자의 제조)

  • Shim, Gyurak;Jeong, Seong-Geun;Hong, Woogyeong;Kang, Koung-Ku;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.826-831
    • /
    • 2018
  • This study presents fabrication of bi-compartmental particles labeled by multiple fluorescence. To compartmentalize fluorescent expression at the particle, two fluorescent dyes with less overlap of the excitation and emission spectra are selected. To ensure the fluorescence stability, the fluorescent dyes contain acrylate functional groups in the molecules so that they can be cross-linked together with monomers constituting the particle. Strong fluorescent expression and compartmentalization were observed at the particle fabricated using the selected fluorescent dyes through confocal microscopy. Furthermore, long-term fluorescence stability was verified by measuring fluorescent expression and intensity for 4 weeks. We anticipate that the bi-compartmental particles labeled by multiple fluorescence can be widely used for multi-target drug delivery system, analysis of 3 dimensional Brownian motion, and investigation of 3 dimensional complex self-assembled morphologies.

Characteristics of EMR emitted by coal and rock with prefabricated cracks under uniaxial compression

  • Song, Dazhao;You, Qiuju;Wang, Enyuan;Song, Xiaoyan;Li, Zhonghui;Qiu, Liming;Wang, Sida
    • Geomechanics and Engineering
    • /
    • v.19 no.1
    • /
    • pp.49-60
    • /
    • 2019
  • Crack instability propagation during coal and rock mass failure is the main reason for electromagnetic radiation (EMR) generation. However, original cracks on coal and rock mass are hard to study, making it complex to reveal EMR laws and mechanisms. In this paper, we prefabricated cracks of different inclinations in coal and rock samples as the analogues of the native cracks, carried out uniaxial compression experiments using these coal and rock samples, explored, the effects of the prefabricated cracks on EMR laws, and verified these laws by measuring the surface potential signals. The results show that prefabricated cracks are the main factor leading to the failure of coal and rock samples. When the inclination between the prefabricated crack and axial stress is smaller, the wing cracks occur first from the two tips of the prefabricated crack and expand to shear cracks or coplanar secondary cracks whose advance directions are coplanar or nearly coplanar with the prefabricated crack's direction. The sample failure is mainly due to the composited tensile and shear destructions of the wing cracks. When the inclination becomes bigger, the wing cracks appear at the early stage, extend to the direction of the maximum principal stress, and eventually run through both ends of the sample, resulting in the sample's tensile failure. The effect of prefabricated cracks of different inclinations on electromagnetic (EM) signals is different. For samples with prefabricated cracks of smaller inclination, EMR is mainly generated due to the variable motion of free charges generated due to crushing, friction, and slippage between the crack walls. For samples with larger inclination, EMR is generated due to friction and slippage in between the crack walls as well as the charge separation caused by tensile extension at the cracks' tips before sample failure. These conclusions are further verified by the surface potential distribution during the loading process.

A Study on the Development of AR Content for Promoting Memory Learning -Nursing Education Learning Content (암기학습 증진을 위한 증강현실 콘텐츠 개발 연구 - 간호 술기 학습 콘텐츠 중심으로)

  • Suh, Donghee;Suh, Eunyoung
    • Journal of Industrial Convergence
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2021
  • The purpose of this study was to investigate the existing augmented reality (AR) contents in education and to develop digital AR contents to promote the learning outcomes in nursing skills education. AR contents has been widely used in education such as children's books, coloring, or exhibition experiences, but rarely developed in nursing education. We wanted to develop AR contents on nursing skills which required memorization of complex contents. In order to improve nursing students' memorization skills, we developed AR techniques holding and executing cameras along with game elements of time and points. In order to give the effect of placing objects in front of the user's eyes, an augmented reality camera was applied, and a total of 40 levels were created to produce the sequence of nursing techniques. This study showed that learning contents in the medical field requiring expertise could be implemented as AR contents. The content developed in this study will be used as a learning aid for nursing students.