• Title/Summary/Keyword: complex load

Search Result 947, Processing Time 0.024 seconds

Hybrid PSO-Complex Algorithm Based Parameter Identification for a Composite Load Model

  • Del Castillo, Manuelito Y. Jr.;Song, Hwachang;Lee, Byongjun
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.464-471
    • /
    • 2013
  • This paper proposes a hybrid searching algorithm based on parameter identification for power system load models. Hybrid searching was performed by the combination of particle swarm optimization (PSO) and a complex method, which enhances the convergence of solutions closer to minima and takes advantage of global searching with PSO. In this paper, the load model of interest is composed of a ZIP model and a third-order model for induction motors for stability analysis, and parameter sets are obtained that best-fit the output measurement data using the hybrid search. The origin of the hybrid method is to further apply the complex method as a local search for finding better solutions using the selected particles from the performed PSO procedure.

CCQC modal combination rule using load-dependent Ritz vectors

  • Xiangxiu Li;Huating Chen
    • Structural Engineering and Mechanics
    • /
    • 제87권1호
    • /
    • pp.57-68
    • /
    • 2023
  • Response spectrum method is still an effective approach for the design of buildings with supplemental dampers. In practice, complex complete quadratic combination (CCQC) rule is always used in the response spectrum method to consider the effect of non-classical damping. The conventional CCQC rule is based on exact complex mode vectors. Sometimes the calculated complex mode vectors may be not excited by the external loading and errors in the structural responses always arise due to the mode truncation. Load-dependent Ritz (LDR) vectors are associated with the external loading and LDR vectors not excited can be automatically excluded. Also, contributions of higher modes are implicitly contained in the LDR vectors in terms of static responses. To improve the calculation efficiency and accuracy, LDR vectors are introduced in the CCQC rule in the present study. Firstly, the generation procedure of LDR vectors suitable for non-classical damping system is presented. Compared to the conventional LDR vectors, the LDR vectors herein are complex-valued and named as complex LDR (CLDR) vectors. Based on the CLDR vectors, the CCQC rule is then rederived and an improved response spectrum method is developed. Finally, the effectiveness of the proposed method in this paper is verified through three typical non-classical damping buildings. Numerical results show that the CLDR vector is superior to the complex mode with the same number in the calculation. Since the generation of CLDR vectors requires less computational cost and storage space, the method proposed in this paper offers an attractive alternative, especially for structures with a large number of degrees of freedom.

공동주택단지의 개발계획단계 시 에너지 수요예측 프로세스에 관한 연구 (A Study on the Process of Energy Demand Prediction of Multi-Family Housing Complex in the Urban Planning Stage)

  • 문선혜;허정호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.304-310
    • /
    • 2008
  • Currently energy use planning council system is mandatory especially for the urban development project planned on a specified scale or more. The goal of existing demand prediction was to calculate the maximum load by multiplying energy load per unit area by building size. The result of this method may be exaggerated and has a limit in the information of period load. The paper suggests a new forecasting process based on standard unit household in order to upgrade the limit in demand prediction method of multi-family housing complex. The new process was verified by comparing actual using amount of multi-family housing complex to forecasting value of energy use plan.

  • PDF

주상복합의 실외기 형태에 따른 냉방시스템 성능 평가 (The performance evaluation of outdoor unit cooling system in a residential apartment complex)

  • 경서경;김윤진;임정희;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

PLF(Probabilistic Load Flow)를 이용한 모선 전압 안전도 평가 (Security Assessment for Bus Voltages Using Probabilistic Load Flow)

  • 이승혁;정창호;김진오;김태균;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.28-30
    • /
    • 2003
  • Probabilistic Load Flow(PLF) solution based on the method of moments is used for security assessment of bus voltages in power systems. Bus voltages, line currents, line admittances, generated real and reactive power, and bus loads are treated as complex random variables. These complex random variables are known in terms of probability density functions(PDF). Also, expressions for the convolutions of complex random variables in terms of moments and cumulants have been derived. Proposed PLF solution using the method of moments is fast, because the process of convolution of various complex random variables is performed in moment and cumulant domain. Therefore, the method is applied to security assessment of power systems in this paper. Finally, system operator also can be used information of security assessment to improve reliability of power systems.

  • PDF

Homogenized limit analysis of masonry structures with random input properties: polynomial Response Surface approximation and Monte Carlo simulations

  • Milani, G.;Benasciutti, D.
    • Structural Engineering and Mechanics
    • /
    • 제34권4호
    • /
    • pp.417-447
    • /
    • 2010
  • The uncertainty often observed in experimental strengths of masonry constituents makes critical the selection of the appropriate inputs in finite element analysis of complex masonry buildings, as well as requires modelling the building ultimate load as a random variable. On the other hand, the utilization of expensive Monte Carlo simulations to estimate collapse load probability distributions may become computationally impractical when a single analysis of a complex building requires hours of computer calculations. To reduce the computational cost of Monte Carlo simulations, direct computer calculations can be replaced with inexpensive Response Surface (RS) models. This work investigates the use of RS models in Monte Carlo analysis of complex masonry buildings with random input parameters. The accuracy of the estimated RS models, as well as the good estimations of the collapse load cumulative distributions obtained via polynomial RS models, show how the proposed approach could be a useful tool in problems of technical interest.

Improvement to Crack Retardation Models Using ″Interactive Zone Concept″

  • Lee, Ouk-Sub;Chen, Zhi-Wei
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권4호
    • /
    • pp.72-77
    • /
    • 2002
  • The load interaction effect can be best illustrated by the phenomenon of overload retardation. Some prediction methods for retardation are reviewed and the problems discussed in the present paper. The so-called under-load effect much of the retardation disappears if a very low level minimum stress follows the overload, is also of importance for a prediction model to work properly under random load spectrum. The concept of Interactive Zone (IZ) fully considering reversed plasticity during unloading was discussed. This IZ concept can be combined with existing models to derive some improved models that can naturally take account of the under-load effect. Some simulations by IZ improved models for test under complex load sequences including multiple overloads and both over/under loads are compared with test results. It is seen that the improvement by IZ concept greatly enhanced the ability of existing models to accommodate complex load interaction effects.

지형에 따른 육상풍력발전단지 난류강도 및 피로 하중 비교 분석 (Comparison Analysis of Turbulence Intensity and Fatigue Load of Onshore Wind Farms According to Terrain)

  • 김영휘;김민지;백인수
    • 풍력에너지저널
    • /
    • 제14권4호
    • /
    • pp.57-67
    • /
    • 2023
  • This study aimed to investigate differences in turbulence intensity and turbine loads among onshore wind farms located in various types of terrain. To achieve this, simulations were conducted for two onshore wind farms with identical wind turbines and capacity but situated on complex and flat terrains. The simulations used meteorological data gathered over a 10-year period from automatic weather stations nearest to the wind farms. WindSim and WindPRO software tools were employed for wind field and load analysis, respectively. The simulation results revealed that wind farm A, situated on complex terrain, exhibited significantly higher effective turbulence intensity than wind farm B on flat terrain, as expected. Consequently, the load indices of several wind turbines exceeded 100 % in wind farm A, indicating that the turbines could not reach their design lifespan. From the simulation study, aimed at reducing both the effective turbulence intensity and turbine loads, it became evident that while increasing turbine spacing could decrease effective turbulence intensity to some extent, it couldn't completely resolve the issue due to the inherently high ambient turbulence intensity on complex terrain. The problem with wind turbine loads could only be completely resolved by using wind turbines with a turbine class of A+, corresponding to a reference turbulence intensity of 0.18.

Investigation of rotation and shear behaviours of complex steel spherical hinged bearings subject to axial tensile load

  • Shi, Kairong;Pan, Wenzhi;Jiang, Zhengrong;Lv, Junfeng
    • Structural Engineering and Mechanics
    • /
    • 제73권2호
    • /
    • pp.123-132
    • /
    • 2020
  • Steel spherical hinged bearings have high loading capacity, reliable load transfer, flexible rotation with universal hinge and allowance of large displacement and rotation angle. However, bearings are in complex forced states subject to various load combinations, which lead to the significant influence on integral structural safety. Taking the large-tonnage complex steel spherical hinged bearings of Terminal 2 of Guangzhou Baiyun International Airport as an example, full-scale rotation and shear behaviour tests of the bearings subject to axial tensile load are carried out, and the corresponding finite element simulation analyses are conducted. The results of experiments and finite element simulations are in good agreement with the coincident development tendency of stress and deformation. In addition, the measured rotational moment is less than the calculated moment prescriptive by the code, and the relationship between horizontal displacement and horizontal shear force is linear. Finally, based on these results, the rotation and shear stiffness models of bearings subject to axial tensile load are proposed for the refinement analysis of integral structure.

공동주택 단지 배치유형별 PV시스템 최적 설치면적 및 전기부하 기여율 평가 연구 (A Study on the Power Saving Fraction of Site Electrical Load depending on the installation area of PV system in Apartment Complex)

  • 윤종호;박재성;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.60-66
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex through the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the shading effect of buildings. Electrical load profile of typical Korean apartments were investigated for the load matching analysis. To calculate an annual total PV output, we used MERIT program which is a hourly based load matching tool developed by ESRD. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending on a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡtype revealed the best option for the maximum output of PV system.