• 제목/요약/키워드: comparison in measurement

검색결과 2,998건 처리시간 0.03초

EAV의 측정치(測定値)와 사상체질유형(四象體質類型) 및 중풍(中風)과의 상관성(相關性)에 관한 연구(硏究) (A Study of The Correlativity in EAV(Electroacupuncture According to Voll)measurement valvues, Sasang Constitution Classfication and CVA(Cerebrovascular accident))

  • 김종원;고병희;송일병
    • 사상체질의학회지
    • /
    • 제7권2호
    • /
    • pp.59-88
    • /
    • 1995
  • Three groups have participated in this study. 1) The first group consists of 57 patients were who had been treated in the Oriental Medical Hospital at Kyung Hee Medical Center. 2) The second group consists of 37 outpatients who had been treated in the Oriental Medical Hospital at Kyung Hee Medical Center. 3) The third group consists of 76 students of the Oriental Medical School at Kyung Hee University. The following conclusions were made in comparison with EAV measurement values, SaSang Constitution Classfication and CVA. 1. The following conclusions were made in comparison with EAV measurement values and Type(SaSang Constitution Classfication). 1) The analsis of the Correlation in Normal group with EAV measurement values and Type(SaSang Constitution Classfication). 2) The analysis of the correlation in patient group with EAV measurement values showed significant differences in Right meridians(Nerval degeneration vessel, Circulation, Allergy) and in Left meridian(Liver). 3) The analysis of the correlation in Total(Normal+patient)group with EAV measurement values showed significant differences in Right meridians(Large intestine, Nerval degeneration vessel, Circulation, Allergy, Pancreas) and in Left meridians(Lymph vessel, Nerval degeneration vessel, Spleen, liver). 4) The above results showed common-significant differences in Right Allery meridian and in Left Liver meridian. 2. The analysis of the correlation in EAV measurement values and Group (Cerebrovascular accident) showed significant differences in Right meridians(Lymph vessel, Lung, Nerval degeneration vessel, Allergy, Paren & Epith. degeneration vessel, Triple warmer, Heart, Pancreas, Stomach, Fibroid degeneration vessel, Skin, Fatty degeneration vessel, Heart, Stomach, Fibroid degeneration vessel, Skin, Fatty degeneration vessel, Bile duct, Kidney). 3. The analysis of the correlation in EAV measurement values and Para(GROUPS according to PARALYSIS)showed significant differences in Left Stomatch meridian. The analysis of the correlation in EAV measurement values and Para(GROUPS according to PARALYSIS) about the differance of right measurement values and left measurement values showed significant differences in Nerval degeneration vessel, Stomatch, Gall bladder & Bile duct, Kidney and Urinary Bladder meridians. 4. The analysis of the correlation in EAV measurement values and Compl(GROUPS according to COMPLICATION with CVA)showed significant differences in Right meridians(Lymph vessel, Articular degeneration vessel, Fatty degeneration vessel) and in Left meridians(Lung, Stomatch, Fatty degeneration vessel). 5. The analysis of the correlation in Type and MORPHOROGICAL DIAGRAMING (HTOUPS according to MORPHOROGY) showed significant differences in Cranium region, Chest region, Stomatch region and Umbilicum region. 6. The analysis of the correlation in BAZ measurement values and Group(Cerebral Vascular Attack)showed significant differences, the analysis on the correlation of BAZ measurement values and Type(SaSang Constitution Classfication) didn't show any significant differences. 7. In comparison with Actual measurement vales and Voll's measurement values, BAZ measurement values agree with Voll's measurement values but CMP measurement values lower than the Voll's measurement values. Later We have to research further about classifications of race, age, sex etc. The EAV measurement values have Group(Cerebrovascular accident) more correlative than Type(SaSang Constitution Classfication). The EAV may well be that it will be used as an accessory method in SaSang Constitution Classfication and as a diagnostic method in medicine too.

  • PDF

다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석 (Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP)

  • 지주연;박승용;이광우;박경민;황순홍;김동호;이영준
    • 한국환경과학회지
    • /
    • 제22권2호
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

레이저를 이용한 테이블 처짐 측정과 시뮬레이션에 관한 연구 (A Study on the Measurement for Table Deflection using Laser Interferometer and Simulation)

  • 김민주
    • 한국생산제조학회지
    • /
    • 제8권6호
    • /
    • pp.55-63
    • /
    • 1999
  • The acceleration of the performance of machine tools influences the development of the semi-conductor and optical technology as the development of NC and measurement technology. Because the measurement has been done to unload condition without considering of mechanical stiffness in the case of machining center as we measure the quasi-static error of machine tools on general study people who works on the spot has many problems on the data value. Also there are no satisfiable results until now in spite of many studys about this because the deflections of the table and the shaft supporting a workpiece influence, influence the accuracy of the table and shaft supporting a workpiece influence the accuracy of the workpiece. And there is doubt about the inspection method of measured error. In this paper Therefor we will help working more accurately on the spot by measuring analyzing displaying the defoec-tion of the table and support shaft when we load on the table and the support shaft of machining center using laser interfer-ometer. Also we try to settle new conception of the measurement method and more accurate grasp of the deflection tenden-cy by verifing the tendency of the error measured through the comparison of the simulated error measured through the comparison of the simulated error using ANSYS a common finite element analysis program which is able to measure heat deformation material deformation and error resulted from this study.

  • PDF

A Study on Weld Bead Profile Measurement System for Use in Automatic Weld Bead Removal System

  • Lee, Jeong-Woo;Lee, Eun-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.194-197
    • /
    • 1999
  • Automatic weld bead removal system is consisted of bead removal tool, bead profile measurement system and tool motion control system. In this paper, design of weld bead profile measurement system which is used for automatic weld bead removal system is described. The system measures the weld bead position, normal vector of the auto-body and weld bead profile. The optical sensor with structured laser beam is used as a sensor and comparison of the sensor that can be used for this purpose is discussed in detail. The measurement process and the related software developed for this purpose are also described. A median filter, average filter and long line filters are used and their effects in bead profile measurement are discussed. The measurement system is integrated into automatic bead removal system and is used to remove weld bead in rear pillar of automotive body. The whole system operates well in automotive body assembly line and thus the system is proved to be good for this purpose.

  • PDF

P018 Comparison between Cutoff Probe and Langmuir Probe: Focused on Measurement Technique Error

  • 권준혁;김대웅;유신재;신용현
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.235.1-235.1
    • /
    • 2014
  • Precise measurement of plasma parameters including density and temperature is the most essential part for understanding plasma characteristics. To persue more accurate measurement, it is very important to understand the intrinsic error of the measurement method. In this paper, we performed the plasma measurement with different method; langmuire probe and cutoff probe. Both measurement technology are known to be exactly correlate with etch other. We conducted the four set of same experiments process by diffrent persons to observe the intrinsic error based on measurement tools. As a result, the cutoff probe is relatively reliable then the Langmuir probe. This difference is analyzed to be intrinsic since it cames from the inevitable error such as manufacturing of probe tip. From this study, we sure that it is good decision to choose cutoff probe as repeatable measurement independent with intrinsic human factor.

  • PDF

교량 계측 정보 관리를 위한 데이터베이스 설계 (The Database Design for the Management of Bridge Measurement Information)

  • 황진하;박종회;조대현
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.126-132
    • /
    • 2004
  • The database design for the management of bridge measurement information is presented in this paper. To express the associated data generated during the whole process of ambient measurement efficiently, requirements analysis for database construction is performed. And to define objects and organize schema conceptual and logical design are performed, which convert data model into logical schema. Finally, physical design is performed using DDL(data defined language). This database is based on the object-relational data modeling approach that has rich expressive power and good reusability in comparison with the traditional entity-relational modeling.

  • PDF

충격전압 재단과 측정을 위한 보상회로에 관한 연구 (A Study on the Compensation Method in the Measuring System for Chopped Lightning Impulse)

  • 김익수;김영배;김진기;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1895-1897
    • /
    • 1996
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard (IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Comparison tests of dividers for chopped lightning impulse measurement were rallied out by KERI. The 700kV shielded resisitive divider with and without compensation element were done comparison test with 300kV PTB divider which have the similar charateristics as that were circulated among the laboratories. This paper reports on the calculation results of response charateristics obtained by EMTP and the comparison test results with chopped lightning impulse voltages from 150kV to 250kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

측정방법 및 기상상태에 따른 PM-10 질량농도 비교 (Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions)

  • 정창훈;박진희;황승만;정용국
    • 한국입자에어로졸학회지
    • /
    • 제5권2호
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

Performance Test of a Real-Time Measurement System for Horizontal Soil Strength in the Field

  • Cho, Yongjin;Lee, DongHoon;Park, Wonyeop;Lee, Kyouseung
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.304-312
    • /
    • 2016
  • Purpose: Soil strength has been measured using a cone penetrometer, which is making it difficult to obtain the spatial data required for precision agriculture. Our objectives were to evaluate real-time horizontal soil strength (RHSS) to measure soil strength in real time while moving across the field. Using the RHSS data, the tillage depth was determined, and the power consumption of a tractor and rotavators were compared. Methods: The horizontal soil-strength index (HSSI) obtained by the RHSS was compared with the cone index (CI), which was measured using a cone penetrometer. Comparison analysis in accordance with the measurement depth that increased at 5-cm interval was conducted using kriged maps at six sensing depths. For tillage control and evaluation of the power consumption, the system was installed with a potentiometer for tillage depth, a torque sensor from the rear axle, and a power take-off (PTO) shaft. Results: The HSSI was lower than the CI, but they were the same at 54.81% of the total grids for the 5-cm depth and at 3.85% for the 10-cm depth. In accordance with the recommended tillage map, tillage operations between 0 and 15 cm left 2.3% and 7% residue cover on the soil, and that between 20 and 10 cm covered a wider utilization of 3% and 18.4%, respectively. When the tillage depth was 15 cm, the comparison result of the power requirements between the PTO and rear axle in terms of control performance revealed that the maximum power requirements of the axle and PTO were 44.63 and 23.24 kW, respectively. Conclusions: An HSSI measurement system was evaluated by comparison with the conventional soil strength measurement system (CI) and applied to a tractor to compare the tillage power consumption. Further study is needed on its application to various farm works using a tractor for precision agriculture.

반전법을 이용한 축 직각도 측정방법 (Measurement of Axis Squireness by using Reversal Method)

  • 이창우;송준엽;하태호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.436-439
    • /
    • 2005
  • In general a square master and a dial gauge are used to measure the axis squareness on the spot. This method is a comparison measurement and its accuracy depends on the square accuracy wholly. Therefore the accuracy of a square master is very important and it is impossible that the accuracy of a square measurement is superior to the accuracy of a square master. In this paper, the new method of square measurement is proposed for measuring square without a square master and easily. This method is an absolute measurement by using a reversal method and can be used to measurement the accuracy of a square master.

  • PDF