• Title/Summary/Keyword: compare

Search Result 30,684, Processing Time 0.045 seconds

A Comparison of Estimation in an Unbalanced Linear Mixed Model (불균형 선형혼합모형에서 추정량)

  • 송석헌;정병철
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.2
    • /
    • pp.337-354
    • /
    • 2002
  • This paper derives three estimation methods for the between group variance component for serially correlated random model. To compare their estimation capability, three designs having different degree of unbalancedness are considered. The so-called empirical quantile dispersion graphs(EQDGs) used to compare estimation methods as well as designs. The proposed conditional ANOVA estimation is robust for design unbalancedness, however, ML estimation is preferred to the conditional AOVA and REML estimation regardless of design unbalancedness and correlation coefficient.

Goodness-of-Fit Test for the Normality based on the Generalized Lorenz Curve

  • Cho, Youngseuk;Lee, Kyeongjun
    • Communications for Statistical Applications and Methods
    • /
    • v.21 no.4
    • /
    • pp.309-316
    • /
    • 2014
  • Testing normality is very important because the most common assumption is normality in statistical analysis. We propose a new plot and test statistic to goodness-of-fit test for normality based on the generalized Lorenz curve. We compare the new plot with the Q-Q plot. We also compare the new test statistic with the Kolmogorov-Smirnov (KS), Cramer-von Mises (CVM), Anderson-Darling (AD), Shapiro-Francia (SF), and Shapiro-Wilks (W) test statistic in terms of the power of the test through by Monte Carlo method. As a result, new plot is clearly classified normality and non-normality than Q-Q plot; in addition, the new test statistic is more powerful than the other test statistics for asymmetrical distribution. We check the proposed test statistic and plot using Hodgkin's disease data.

The Flow Characteristics around Circular Cylinder of Pressure Interference with Slits (표면압력이 상호 간섭되는 슬릿을 가진 원주의 후류 유동 특성)

  • 부정숙;김진석;류병남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.736-744
    • /
    • 2003
  • This study is conducted to investigate aerodynamic forces and wake structures about the pressure interference of a circular cylinder with slits. An experimental investigation of a circular cylinder with slits is carried out in uniform flow in the range of Reynolds number from 8,000 to 32,000 using X-type hot wire. Flow visualization is executed by smoke-wire method to understand the mechanism of these vortex formation process. Inspection in the wake at X/D=5.5 of the cylinder with the slits suggested that a strong vortex-shedding pattern for these cylinders is revealed compare with a circular cylinder without slits. It is found that the rolling up position of shear layer of the cylinder with slits is shorten compare with a circular cylinder without slits.

Development of High Peformance Geothermal heatexchanger (고성능저가형 지중열교환기 개발연구)

  • An, Hyung-Jun;Baek, Sung-Kwon;Im, Sung-Kyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.470-473
    • /
    • 2007
  • Geothermal heat exchanger(GHEX) is a major component of Geothermal heat pump system(GSHPs). In Common, We use the vertical type GHEX in Korea. But vertical type GHEX needs a high cost for installation, because of drilling the hole which has 200m depth at max. So, We suggest the use of horizontal type GHEX. When we construct buildins, We excavate the ground and we can install the horizontal type GHEX at the excavated underground. It's very cheap and convenient method compare to vertical type GHEX installation. This study is peformed to estimate the peformance of horizontal type GHEX and to analyze effects of heat exchanger types and undergroundwater. As the result, slinky type GHEX has a 66% efficiency compare to vertical type GHEX and mat type has a 201% efficiency at the undergroundwater zone.

  • PDF

Amine Gases Detecting Studies using the Compounds on the Urethane Nano Web and Laminating Film (아민 감지 화합물을 이용한 우레탄 나노웹과 라미네이팅 필름의 아민 가스 감지특성 연구)

  • Lee, Jun-Hee;Seo, Hye-Ji;Kang, Yoo-Jung;Lee, Do-Hyun
    • Textile Coloration and Finishing
    • /
    • v.25 no.1
    • /
    • pp.70-74
    • /
    • 2013
  • For amine gas detection, we incorporated two well-known isomers, 2-chloro-3,5-dinitro-benzotrifluoride and 4-chloro-3,5-dinitro-benzotrifluoride, in polyurethanes. Nanoweb and thin film were prepared by electrospinning and lamination, respectively, in order to compare their sensing behaviors. Moreover, we studied photophysical property using UV-Vis spectrometer and observed surface area through scanning electron microscope to compare between the Nanoweb and thin film. We found out that nanowebs exhibited high sensitivity specifically to primary amine gas.

Effect of Suppository Bases on Absorption of Lithium Carbonate (좌제기제가 탄산리튬의 흡수에 미치는 영향)

  • Kim, Yong-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.4
    • /
    • pp.148-151
    • /
    • 1986
  • This paper was designed to investigate the influence of different suppository bases on both the rectal absorption and dissolution rate of lithium carbonate, and to compare bioavailability from rectal administration with that from oral administration. The dissolution rates were in such order as PEG 4000, surfactant A (Witepsol 15+sodium lauryl sulfate), surfactant B (Witepsol 15+cholic acid), Witepsol 15 and cacao butter. Among various suppository bases, the blood level of lithium carbonate after rectal administration was increased in the following order: surfactant A>surfactant B>PEG 4000>Witepsol 15>cacao butter. When it comes to compare oral with rectal administration in AUC values, surfactants and PEG 4000 showed similar blood levels to oral administration, but lipophilic bases such as Witepsol 15 and cacao butter showed far lower blood level than oral administration. Peak time in oral administration was 2 hrs, but those in rectal administration using various suppository bases were $6{\sim}8$ hrs.

  • PDF

A Comparative Study on the Runoff Characteristics from Watershed Using SWAT and HSPF (SWAT과 HSPF의 유출특성 비교)

  • Hwang, Ha-Sun;Yoon, Chun-Gyeng
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.457-460
    • /
    • 2002
  • Development and application of nonpoint pollutant source model need pertinent runoff simulation for expecting good simulation result of yield of nonpont pollutant and it's move. this study purpose was compare to runoff height among Observed of Regression, HSPF and SWAT in hukchun basis loacated Gyeonggi province yangpeong-gun in two years($1998{\sim}1999$). Result, runoff height were Regression, SWAT, HSPF is 2578.96, 2526.44, 2547.21mm respectively, Nash-Schutcliff' simulation efficiency, compare to observed, was 70.22, 73.71% respectively so two simulation run off height was pertinent. If Regression method use excess observed arrange, it include error. so it's importance using pertinent arrange of observed runoff height.

  • PDF

A Study on Performance Comparison of COTS Operating Systems for a Mission Computer Using UAV Collision Avoidance Algorithm (무인기 충돌회피 알고리즘을 이용한 임무컴퓨터용 상용기성품 운영체계 성능 비교에 대한 연구)

  • Yang, Jun-Mo;Jeon, Yu-Ji;Lee, Sang-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.4
    • /
    • pp.6-11
    • /
    • 2016
  • There has been an increase in the number of researches on the segment for commercialization after developing avionics systems. In this paper, we have applied a commercial off-the-shelf(COTS) operating systems in an aircraft mission computer. We used UAV collision avoidance algorithms to compare the performance of COTS operating systems. The UAV collision avoidance algorithms were tested on different operating systems to compare the performances of the operating systems. The measured parameters are memory usage and processing time. We have verified that the UAV collision avoidance algorithms worked successfully and compared the performance of each operating system.

Benchmark tests of MITC triangular shell elements

  • Jun, Hyungmin;Mukai, Paul;Kim, San
    • Structural Engineering and Mechanics
    • /
    • v.68 no.1
    • /
    • pp.17-38
    • /
    • 2018
  • In this paper, we compare and assess the performance of the standard 3- and 6-node MITC shell elements (Lee and Bathe 2004) with the recently developed MITC triangular elements (Lee et al. 2014, Jeon et al. 2014, Jun et al. 2018) which were based on the partitions of unity approximation, bubble node, or both. The convergence behavior of the shell elements are measured in well-known benchmark tests; four plane stress tests (mesh distortion test, cantilever beam, Cook's skew beam, and MacNeal beam), two plate tests (Morley's skew plate and circular plate), and six shell tests (curved beam, twisted beam, pinched cylinder, hemispherical shells with or without hole, and Scordelis-Lo roof). To precisely compare and evaluate the solution accuracy of the shell elements, different triangular mesh patterns and distorted element mesh are adopted in the benchmark problems. All shell finite elements considered pass the basic tests; namely, the isotropy, the patch, and the zero energy mode tests.

Development Model for Estimating Critical Path Probability of Element Path in PERT (PERT 요소공정의 주경로 확률 산정 모델 개발)

  • Youn, Deuk-No;Kim, Tae-Gon;Han, Yi-Cheol;Lee, Jeong-Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.27-34
    • /
    • 2010
  • The PERT is one form of probabilistic network and can have many critical paths in the concept of each work has dispersed complete time. Here we propose two operators to estimate the probabilistic complete time about serial and parallel connections, and in each junction node, probability of critical path is estimated by new operator. Then we compare the estimated results with robability of critical path with deterministic CPM and Monte Carlo simulation (MCS). Our results show that all paths in PERT can be critical path, and proposed operators are efficient and accurate probabilistic calculators compare MCS result.