• Title/Summary/Keyword: communication cable

Search Result 439, Processing Time 0.026 seconds

Cable Tunnel Monitoring System by Wireless Sensor Network (무선센서 네트워크에 의한 지하 통신구 터널 모니터링 연구)

  • Kim, Hyung-Woo;Moon, Tae-Gyun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.549-552
    • /
    • 2008
  • In this study, we deployed the cable tunnel inspection and monitoring system by wireless sensor network. It is shown that the wireless sensor network which is composed of sensor, wireless communication module, and gateway can be applied to cable tunnel monitoring system. Sensors considered herein are flame detection sensor, flood detection sensor, intruder detection sensor, and temperature sensor, etc. It is also found that the wireless sensor network can deliver sensing data reliably by wireless sensing technology. The gateway system that can transmit sensed data to server by CDMA is developed. Monitoring system is constructed by web service technology, and it is observed that this system can monitor the present state of tunnel without difficulties. The system provides an alternative to inspecting and monitoring the tunnel efficiently where the conventional wired system is infeasible.

  • PDF

A Study on the Fault Location Using Multiscale Correlation in Underground Power Cable Systems (Multiscale Correlation을 이용한 지중송전계통 고장점 추정에 관한 연구)

  • Jung Chae Kyun;Lee Jong Beom;Kang Ji Won
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.557-559
    • /
    • 2004
  • The study of applying wavelet transform in power cable system fault location has been recognized by many researchers and investigated. For performance of fault location, the fault generated transients can be captured at one end of the cable or both ends. Between two approaches, single-ended approach is less expensive and more reliable as it doesn't need communication link between the ends of the cable. So, we performs the approach based on the one. In this paper, we are going to introduce a new algorithm to discriminate the transient and the reflected signal using wavelet coefficient. For wavelet transform, the stationary wavelet transform(SWT) is applied instead of conventional DWT because SWT has redundancy properties which is more useful in noisy signal processing.

  • PDF

Implementation of Efficient Cable Spreading Algorithm and Automation Program for Electrical Equipment in Power Plant (발전소 전기설비를 위한 효과적인 케이블 포설 알고리즘 및 자동화 프로그램 구현)

  • Park, Ki-Hong;Kang, An Na;Choi, Hyo Beom;Lee, Yang Sun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2229-2236
    • /
    • 2014
  • In this paper, we proposed and implemented the automated cable-spreading program which can be done effectively cabling plan for electrical equipment in power plant. Cause the process of existing cable-spreading design was written in by hand, there are grossly inefficient gain by a personal and time investment with cable omission and unfixed overfill value. Proposed automation program for cable-spreading, which is coded cable and raceway, can calculate the overfill value and raceway change. Some experiments are conducted so as to verify the proposed model, and as a result, implemented cable-spreading program is well performed.

A study on Lifetime Evaluation of High-power Cables Based on Temperature Changes (온도변화에 따르는 고전력 케이블의 수명 변화 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.273-278
    • /
    • 2015
  • In order to meet increasing power demands, electrical capacity of equipment for power transfers should become larger accordingly. The equipment used for producing and delivering high-voltage power is also required to operate with a high degree of reliability. The stable operation of power equipment is a necessity, not an option. The current through the power cable, the only device to deliver high power, generates a Joule heat, which causes a deteriorating process on the cable system. The XLPE cable is manufactured in such a manner that it can operate for 30 years at $90^{\circ}$, but there is no guarantee that each cable will reach its projected lifetime of 30 years. In this paper, we have measured the temperatures of nine power cables in operation, based on the theory of cable longevity. In order to study the relationship between temperature and longevity, we have devised a new set of equipment and installed it at Korea Western Power Co., Ltd. located in Taean.

A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station (화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.187-193
    • /
    • 2018
  • There has been a gradual increase in the demand for the electric power in Korea. In order to meet the demand, power station should have technical functions with increased effectiveness. When accident happens in electric machinery at power stations, huge amount of economic losses and mulfunction of equipments occur. One of the accidents is a deteriorated cables operating power stations. In order to prevent cable accident in advance, we should monitor the insulation status of the cable. Cable accidents are resulting from the junctions. We have developed and installed a device in order to identify the status of junction part of power cable at Korea Western Power Co., Ltd.. We performed an accurate diagnosis for the stable utilization of junctions where the accidents occurs most frequently, and to increase the reliability. In this paper, we present the concepts of our device and the method of monitoring diagnosis for the stable use of junctions at cables predicting the life time of cables by analyzing the data obtained by the device. We also present the hardware aspect of the device we have developed.

A Study on the Management of Local Channel and Renewed License of Cable TV System Operator in Korea (케이블TV SO의 지역채널 운영 및 재허가 심사에 관한 연구)

  • Jung, In-Sook;Chung, Sang-Yune
    • Korean journal of communication and information
    • /
    • v.54
    • /
    • pp.58-75
    • /
    • 2011
  • This study explores the management of cable local channel and its related issue of renewed license. Programming of the local channel is the special obligation duty on the cable system operators(SO) under the article 70 (3) of the Broadcast Act. The law provides that SO should operate a local channel which produce, program and transmit the local information, a broadcast program guide and the official announcement items etc. under the conditions as prescribed by Presidential Decree. And the article 55 of the Enforcement Decree defines the scope of broadcast program which transmit through the local channels. And the Korea Communications Commission(KCC) grants a renewed licence 3-5 years based on the level of contribution to the development of local community under the article 31 of the Broadcasting Act and the Rules of Broadcast Evaluation. However, the management of local channel does not give the operators real benefit for the investment of a significant cost, and it could be a reason why the local channel programming has not been vitalizing despite of the legal coercion. To solve the several research questions, this study used in-depth interviews with the experts concerned and literature review for the government documents. The result shows that each SO local channel schedule almost 24 hour a day, but much of them is the repeat programming. In addition to that, the outcome reveals that the scale of the cost investment on the local channel is decreasing and the evaluation score of its management is not so positive figures. These result indicates that the policy of the cable local channel needs revised policy alternatives or paradigm on the basis of realistic goals.

  • PDF

Design and fabrication of the GPS antenna system including RF-stage (RF 수신부를 내장한 GPS 안테나 시스템의 설계 및 제작)

  • 홍성일;이정호;변건식;정만영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.99-107
    • /
    • 1996
  • When GPS (global positioning system) is used as synchronous signal in CDMA digital cellular base station system and high speed digital synchronous communication network, antenna cable length is increased, comparing with other GPS application such as positioning or car navigation. In this paper, it is proposed that a type of new GPS antenna system including RF stage for reduction of cable loss in case of long cable.The antenna system with TMPA(truncated-corners microstrip patch antenna) is designed and fabricated because GPS signal has RHCP (right-hand circular polarization), consequently antenna size can be made small size. LNA (low noise amplifier) is designed by using HEMT(high electron mobility transistor)which has lower noise figurae and better AGC characteristics at low voltage than GaAs FET, and we equiped mixer, in GPS antenna unit, which converts from 1575.42MHz to 75.42MHz. As result of comparing between typical system and proposed system when cable length is 60m, 63dB, 55dB and 25dB gain are obtained for RG-316/U, RG-58C/U and RG-213/U, and better characteristics are achieved than typical system as far as cable length is longer.

  • PDF

Consideration for the Repeaterless Transmission in Long Distance Optical Submarine Cable System (장거리 해저 무중계 전송기술 연구)

  • Park, Hong-Tae;Kim, Chun-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.1
    • /
    • pp.40-45
    • /
    • 2007
  • The repeaterless system can be designed by applying EDFA technology in receiver, transmitter and optical cable in the case of connecting several hundred km from coast to coast, between continents or islands. Because of no repeater the repeaterless system do not need power system to feed laser diode in repeater for signal amplification and cooper tuber in submarine cable. So we can be configured more reliable and economical compared to repeater system. But lower loss optical fiber must be used to get enough signal amplitude without the amplification of repeater. This report consider long distance optical repeaterless system by reflecting the limitation factor of optical amplification.

  • PDF