• Title/Summary/Keyword: common-mode rejection

Search Result 29, Processing Time 0.026 seconds

An Enhancement of Channel Separability for Stereophonic Signals by Common Mode Rejection Method (동상분 제거에 의한 입체음향의 채널 분리도 개선)

  • Kwon, Ho-Yeol
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.439-442
    • /
    • 1998
  • In this paper, we firstly suggested C&D (Common mode and Differential mode) model for the representation of a stereophonic signal. Then a measure of stereophonic channel separability is defined as the ratio of differential mode energy to total energy in frequency domain. After that, a new channel separability enhancement scheme is proposed by the control of common mode rejection. Finally, some experimental results are presented in order to verify our scheme.

  • PDF

Common Mode Filter Embedded in Flexible Printed Circuit Board for Multi-Function Cable (다기능 케이블을 위한 연성 회로 기판에 내장된 공통 모드 필터)

  • Byun, Jin-Do;Jung, Sang-Woon;Lee, Keun-Hyung;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.343-351
    • /
    • 2008
  • In this paper, a spiral shaped common mode filter(CMF) embedded in a flexible printed circuit board(FPCB) is proposed for a multi-function cable. The CMF embedded in a FPC cable presents a new concept as a multi-function cable by the common mode rejection characteristics without a surface mounted device(SMD) CMF. The embedded CMF has a wideband common mode rejection bandwidth and an enhanced differential mode characteristics compared to conventional CMFs that use a magnetic material such as a ferrite of high loss. The proposed CMF of 3 turn inductors has a common mode rejection bandwidth from 0.4 GHz to 3.12 GHz and has 1.95 dB at 3 GHz, 6.97 dB at 8 GHz improvements of a differential mode insertion loss compared to the commercial LTCC(Low Temperature Co-fire Ceramics) CMFs.

Development of the speed up x-DSL extender for AM, HF rejection (공중파 제거를 위한 x-DSL 고속화 장치 개발)

  • Min, Gyung-Chan;Oh, Ho-Seuk;Kang, Jeong-Jin;Kim, Sin-Ryeong;Chang, Hark-Sin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.9-14
    • /
    • 2008
  • Intentional city bands and public radio frequencies could reduce the internet transmission speed on the wired lines because AM and HF band are overlapping on the xDSL up and down data steam by way of the wired transmission lines. We were designed the adaptive common mode rejection circuit with 2 way amplifier against public radio frequency. Specially our circuits were applied for power and signal lines. We could reduced the common mode rejection up to 30dB and increased the up stream speed around 1.8 times using a our developed equipments. Also it could expanded the transmission distance up to 1.7 times than old lines.

  • PDF

Enhanced Common-Mode Noise Rejection Method Based on Impedance Mismatching Compensation for Wireless Capsule Endoscopy Systems

  • Hwang, Won-Jun;Kim, Ki-Yun;Choi, Hyung-Jin
    • ETRI Journal
    • /
    • v.37 no.3
    • /
    • pp.637-645
    • /
    • 2015
  • Common-mode noise (CMN) is an unresolved problem in wireless capsule endoscopy (WCE) systems. In a WCE system, CMN originates from various electric currents found within the human body or external interference sources and causes critical demodulation performance degradation. The differential operation, a typical method for the removal of CMN rejection, can remove CMN by subtracting two signals simultaneously received by two reception sensors attached to a human body. However, when there is impedance mismatching between the two reception sensors, the differential operation method cannot completely remove CMN. Therefore, to overcome this problem, we propose an enhanced CMN rejection method. The proposed method performs not only subtraction but also addition between two received signals. Then a CMN ratio can be estimated by sufficient accumulation of division operation outcomes between the subtraction and addition outputs during the guard period. Finally, we can reject the residual CMN by combining the subtraction and addition outputs.

Comparison between a differential and a non-differential amplifier system with two electrodes in bio-potential measurement (생체 전위 측정에서 2-전극 차동 증폭 시스템과 2-전극 비차동 증폭 시스템의 비교)

  • Kang, Dae-Hun;Lee, Chung-Keun;Lee, Sang-Joon;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1977-1978
    • /
    • 2008
  • In this paper, we compare performance of common-mode rejection between a differential and a non-differential amplifier system with two electrodes. A differential amplifier system is constant for common-mode rejection ratio(CMRR) on the frequency domain. But a non-differential amplifier's CMRR is determined by $Z_{FB}/Z_e$ ($Z_{FB}$ ; feedback impedance, $Z_e$; electrode impedance). There is trade-off between a non-differential amplifier's CMRR and its differential input impedance. And a non-differential amplifier system has some advantages for a bio-potential measurement with two electrodes because a designer can control the impedance between the body and system's common.

  • PDF

MOS Transistor Differential Amplifier (MOS Transistor를 이용한 착동증폭기)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.4 no.4
    • /
    • pp.2-12
    • /
    • 1967
  • A pair of insulated-gate metal-oxide-semiconductor field-effect transistor has been used to measure the direct current produced from the ionization chamber in the range of to A. An analisis of direct-current differential amplifier giving the expressions of the common-mode rejection ratio and the rralization of the constant-current generator to give very large effective source resistance has been presented. Voltage gain is 6.6, drift at the room temperature is 1.5mv per day. The common-mode rejection ratio is obtained maximum 84db. These facts give the feasibility of small direct-current measurements by utilizing this type transistors.

  • PDF

A Feasibility Study for Application of Single-Chip Solution for Diagnostic Resting ECG (ECG 원칩 솔루션의 진단용 심전계 적용을 위한 타당성 연구)

  • Kang, Bum-Sun;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.86-94
    • /
    • 2015
  • In order for medical devices to be used outside hospital, they have to be not only of small size but also power consumption has to be kept at low level. This study investigates the feasibility of application of ADS1298 ECG single-chip solution developed by Texas Instruments Inc. for use in development of a new platform for diagnostic resting ECG. To prove the feasibility of commercial products based on the ADS1298 chip, the performance of the ADS1298 chip was measured in terms of input impedance, common mode rejection, frequency response, and input dynamic range using the testing method under the suitability criteria of the IEC 60601-2-25 standard. Result of the this study shows that commercialization of the ECG products based on the ADS1298 ECG single-chip solution that satisfies the international standards would be possible, if the manufactures take the filter characteristics into account in building a new platform for diagnostic resting ECG.

Ultra-Low-Power Differential ISFET/REFET Readout Circuit

  • Thanachayanont, Apinunt;Sirimasakul, Silar
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.243-245
    • /
    • 2009
  • A novel ultra-low-power readout circuit for a pH-sensitive ion-sensitive field-effect transistor (ISFET) is proposed. It uses an ISFET/reference FET (REFET) differential pair operating in weak-inversion and a simple current-mode metal-oxide semiconductor FET (MOSFET) translinear circuit. Simulation results verify that the circuit operates with excellent common-mode rejection ability and good linearity for a single pH range from 4 to 10, while only 4 nA is drawn from a single 1 V supply voltage.

  • PDF

Satellite Battery Cell Voltage Monitor System Using a Conventional Differential Amplifier (종래의 차동증폭기를 사용한 인공위성 배터리 셀 전압 감시 시스템)

  • Koo, Ja-Chun;Choi, Jae-Dong;Choi, Seong-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.113-118
    • /
    • 2005
  • This paper shows a satellite battery cell voltage monitor system to make differential voltage measurements when one or both measurement points are beyond voltage range allowed by a conventional differential amplifier. This system is particularly useful for monitoring the individual cell voltage of series-connected cells that constitute a rechargeable satellite battery in which some cell voltages must be measured in the presence of high common mode voltage.

On-chip Magnetic Sensor with Embedded High Inductance Coil for Bio-magnetic Signal Measurement (생체자기 신호측정을 위한 고인덕턴스 코일 내장형 온칩 자기센서)

  • Lyu, HyunJune;Choi, Jun Rim
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.91-98
    • /
    • 2013
  • Magnetic sensor chip for measuring bio-magnetism is implemented in $0.18{\mu}m$ CMOS technology. The magnetic sensor chip consists of a small-sized high inductance coil sensor and an instrumentation amplifier (IA). High inductance coil sensor with suitable sensitivity and bandwidth for measurement of bio-magnetic signal is designed using electromagnetic field simulation. Low gm operational transconductance amplifier (OTA) using transconductance reduction techniques is designed for on-chip solution. Output signal sensitivity of magnetic sensor chip is $3.25fT/{\mu}V$ and reference noise of 21.1fT/${\surd}$Hz. Proposed IA is designed along with band pass filters(BPF) to reduce magnetic signal noise by using current feedback techniques. Proposed IA achieves a common mode rejection ratio of 117.5dB while the input noise referred is kept below $0.87{\mu}V$.