• Title/Summary/Keyword: combined type

Search Result 2,282, Processing Time 0.028 seconds

A Combined Rotary Compressor-vane Expander (일체형 로타리 압축기-베인 팽창기)

  • Kim, Hyun Jin;No, Young Jae;Kim, Yong Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.12-19
    • /
    • 2015
  • As a means of improving cycle performance of a R410A air-conditioning system, a combined structure of compressor and expander was introduced. A vane rotary type expander was designed to share a common shaft with twin type rolling piston rotary compressor in a housing. Numerical simulation on the performance of the combined compressor and expander was carried out. At ARI condition, the volumetric and total efficiencies of the designed vane expander were 69.37% and 30.23%, respectively. With the application of this expander, the compressor input was reduced by 3.91%, and the cooling capacity was increased by 3.98%. As a result, COP of the air-conditioning system was improved by 8.2%. As the pressure difference between the condenser and the evaporator becomes large, COP improvement increases unless the mass flow rate in the expander exceeds that in the compressor.

An Experimental Study of a Water Type Glazed PV/Thermal Combined Collector Module (액체식 Glazed PVT 복합모듈의 성능실험 연구)

  • Kim, Jin-Hee;Kim, Jun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.260-265
    • /
    • 2008
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic/thermal (PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that converts solar radiation into electricity and heat simultaneously. In general, two types of PVT can be distinguished : glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively low-temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of water type PVT combined module, glass-covered, analyzed. The electrical and thermal performance of the module were measured in outdoor conditions, and the results are analyzed. The results showed that the thermal efficiency of the PVT module was 27.6% average and its PV efficiency was about 10.0% average, both depending on solar radiation, inlet water temperature and ambient temperature.

An Experimental Study on the Drying and Curing Characteristics of Conductive metallic ink using Combined IR and Hot Air Type in the Roll-to-Roll System (R2R 공정에서 적외선가열과 열풍을 혼합한 건조방식에서 전도성 금속 잉크의 건조 및 큐어링 공정 특성에 관한 실험적 연구)

  • Kim, Young-Mo;Hong, Seung-Chan;Lee, Jai-Hyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.73-78
    • /
    • 2010
  • This research is about the drying and curing characteristic of conductivity metallic ink on-line curing device in order to improve the curing time for productivity in RFID Gravure printing. The curing process is carried out to increase the electric conductivity after the metallic ink is printed on the substrate. The metal ink is composed of nano-sized silver or copper particles. In this research, the combined IR and Hot air curing system is used and its results is compared with those of oven, IR and Hot Air type respectively. Generally the curing time in the past is about 3 minutes. But the combined system (IR+Hot Air) in this research shows that curing time is less than 30 seconds. These results is much faster than those of other system. This study can be help to make Roll-to-Roll drying and curing process for mass and continuous production on-line.

Buckling Analysis of Laminated Composite Cylindrical Shell under Combined Load State (복합하중상태에 있는 복합재료 원통형 쉘의 좌굴 거동)

  • Yeo, Kyoung-Su;Yang, Won-Ho;Cho, Myoung-Rae;Sung, Ki-Deug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.119-130
    • /
    • 1999
  • This paper deals buckling behavior of laminated composite cylindrical shells subjected to combination of axial compression and torison. Linear and nonlinear finite element analysis are carried out . the influence of load type, load ratio, fiber orientation angle, stacking sequence, and intial imperfect on buckling behavior is discussed.

  • PDF

A Case Report of Myasthenia Gravis Combined with Thymoma (흉선종양과 Myasthenia Gravis가 합병한 1례 보고)

  • 최수승
    • Journal of Chest Surgery
    • /
    • v.7 no.1
    • /
    • pp.123-126
    • /
    • 1974
  • The incidence of myasthenia gravis in patients with thymomas has been reported from 10 to 50 percent, and the controversy ranges from 8-15 percent. This is the report of myasthenia grayis combined with benign thymoma and obtained relatively good result through surgical treatment at the department of thoracic surgery, National Medical center. The thymoma was mixed type and benign nature. Post operatively this patient was developed myasthenia crisis, and treated with mechanical respirator, and recurred the symptoms about 2months later, but well controlled with medical treatment.

  • PDF

Derivation of Expected Mean Squares (EMS) Using Venn Diagram by the Type of Experimental Design (실험설계 유형별 Venn Diagram을 이용한 EMS 도출)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.695-699
    • /
    • 2011
  • The study presents an efficient design method of Venn Diagram that can be used when implementing the quality design of experiments based on generalizability theory. The paper examines four mixed and combined models that are designed by fixed factor, random factor, crossed factor and nested factor. The models considered in this research are $A^*{\times}B^*{\times}C$, (B: $A^*$)${\times}C$, $A{\times}B{\times}C$ and (B: A)${\times}C$.

  • PDF

A Study on Simultaneous Optimization of Multiple Quality Characteristics for Robust Design

  • Kwon, Yong Man
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.2
    • /
    • pp.142-157
    • /
    • 1996
  • Robust design in industry is an approach to reducing performance variation of quality characteristic values in products and processes. In the Taguchi type robust design, the product array approach using orthogonal arrays is mainly used. However, it often requires an excessive number of experiments. In this paper, for the combined array approach to assign control and noise factors, we propose how to simultaneously optimize multiple quality characteristics. Two examples are illustrated to show the difference between the product-array approach and the combined-array approach.

  • PDF

A Study on the Structure of Combined Architecture of Dang and Sil in the Early Joseon Dynasty -Focusing on the Rectangular Plan and the Gable Roof Meeting at Right Angle- (조선전기 당(堂)·실(室) 결합 건축의 가구특성 분석 -방형 평면의 맞배직교형 지붕 가구를 중심으로-)

  • Kim, Bue-Dyel;Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.26 no.2
    • /
    • pp.31-42
    • /
    • 2017
  • This study investigates how the spatial recognition structure is emerging through the case of rectangular plan combined with a combination of Dang-Sil(堂室) and Gong(工) shape roof, and identifies a type of architecture in the early Joseon Dynasty that has never been revealed. The conclusion of this study is as follows. First, the Dang and the Sil are connected to each other, but the architectural elements such as pillars, frame, and windows are distinguished and appear as separate buildings. Second, the distinction between Dang and Sil is evident by the difference in the number of ridges and the shape of the roof. In addition, the roof and roof framework of the independent rooms and the rooms were common in the right angled architecture where the direction and the expandability of each structure were maintained. Third, the construction of the Dang-Sil combined structure, in which two or more structure frameworks were combined with the rectangular combined flat roof structure, gradually changed into a single structure with a single ridge. Fourth, this change means that people of the early Joseon Dynasty recognized the Dang and Sil as separate architecture, but the strict sense of spatial separation has disappeared over time.

A Case Study on Combined School-Public Library of Gangnam-gu (기초자치단체가 설립한 학교-공공 통합형 도서관 운영사례 -강남구립 학교전자도서관의 경우를 중심으로 -)

  • 한윤옥;이승원
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.14 no.2
    • /
    • pp.59-82
    • /
    • 2003
  • Gannam-gu established 'school digital libraries' in 15 of their elementary schools between September 2001 to October 2002, and now offers library services to both students and residents All expenses and human resources for these libraries are provided by the Gannam-gu and schools provide only their vacant classrooms. This is a good example of combined school-public library The type of combined school-public library can be a useful suggestion for our educational situation. So the purpose of this study is to reveal the actual condition and the efficiency of the library established by Gannam-gu, a well-known case of a combined school-public library.

  • PDF

A Study on Performance Improvement in Cellular IP Using Combined Cache and Different Handoff (통합 캐시 및 차별화된 핸드오프를 이용한 셀룰러 IP의 성능개선에 관한 연구)

  • Seo Jeong Hwa;Kim Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12B
    • /
    • pp.1063-1069
    • /
    • 2004
  • There are some problems with the methods of paging and routing cache(PRC) and quasi soft handoff that are proposed to improve the performance for the transmission of real time data. This paper proposed a reasonable solution of these problems by proposing a new method using a combined cache(CC) and applying a different handoff procedure according to each type of data. The combined cache dose not maintain the handoff state but the idlle/active state. The simulation results in a better performance than the above methods in terms of the control packet traffic load, initial recevied data packet traffic load and arrival tune of real time packet at the epoch of handoff.