Water Injection/Urea SCR System Experimental Results for NOx Reduction on a Light Duty Diesel Engine

  • Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.394-403
    • /
    • 2008
  • The effects of water injection (WI) and urea injection for NOx on a 4-cylinder Direct Injection (DI) diesel engine were investigated experimentally. For water injection, it was installed at the intake pipe and the water quantity was controlled at the intake manifold and Manifold Air Flow (MAF) temperatures while the urea injection was located at the exhaust pipe and the urea quantity was controlled by NOx quantity and MAF. The effects of WI system, urea-SCR system and the combined system were investigated with and without exhaust gas recirculation (EGR). Several experiments were performed to characterize the urea-SCR system, using engine operating points of varying raw NOx emissions. The results of the Stoichiometric Urea Flow (SUF) and NOx map were obtained. In addition, NOx results were illustrated according to the engine speed and load. It is concluded that the NOx reduction effects of the combined system without the EGR were better than those with the EGR-based engine.

A Study on the Installation of Combined Turnout Management System (분기기 통합 관리 시스템 구축에 관한 연구)

  • Kong, Hyun-Jin;Kim, Doo-Guym;Ko, Young-Hwan;Song, Joong-Ho;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1077-1083
    • /
    • 2011
  • Turnout is one of railroad track components. The turnout is used to change train routes to near other sections when keeping the train speed. There are many accidents in the section including the turnout. The number of accidents and errors is 363 for ten years in the section including the turnout and annual average is 36.3. To ensure safety of the turnout, it is necessary to install monitoring systems. By using the monitoring systems, it is able to accumulate related information, develop maintenance and take a step for accidents in advance. Hence, The number of accidents and errors is decreased in the section including the turnout. So, when new turnout is installed, it is needed to use monitoring systems. Therefore, combined turnout management system is needed in Korea. It is possible to perform efficient maintenance because real-time monitoring system by using sensors and data-base management system. In this paper, accidents in the section including domestic turnout are analyzed and foreign combined turnout management system is presented. Hence, articles for installing the combined turnout management system in Korea are proposed.

  • PDF

[ H2S ] Removal Characteristics by Combined System of Bioscrubber and Biofilter (Bioscrubber와 Biofilter 병합 시스템에 의한 H2S 제거특성)

  • Bin, Jung-In;Lee, Byung-Hun;Kam, Sang-Kyu;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.16 no.6
    • /
    • pp.763-769
    • /
    • 2007
  • This study compared the performance of a bioscrubber, a biofilter, and a combined system of bioscrubber and biofilter employed being operated at the laboratory-scale. for the removal of hydrogen sulfide. The bioscrubber maintained 100% removal of hydrogen sulfide up to inlet load of $56\;g-S/m^3{\cdot}hr$, while the removal efficiency was decreased with the increase of inlet load. The biofilter showed 100% removal efficiency up to inlet load of $126\;g-S/m^3{\cdot}h$ and the maximum elimination capacity of $126\;g\;S/m^3{\cdot}h$ for the inlet load of $224\;g-S/m^3{\cdot}h$. On the other hand, the combined system of bioscrubber and biofilter showed 100% removal for an inlet hydrogen sulfide load of up to $85\;g-S/m^3{\cdot}h$ and the maximum elimination capacity of $153\;g-S/m^3{\cdot}h$ for inlet loads of $224\;g-S/m^3{\cdot}h$.

Combined Optimal Design with Minimum Phase System (최소위상시스템을 고려한 통합최적설계)

  • 박중현
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.2
    • /
    • pp.192-196
    • /
    • 2004
  • A combined optimal design problem is discussed taking a 3-D truss structure as a design object. We use descriptor forms for a controlled object and a generalized plant because the structural parameters appear naturally in these forms. We consider not only the minimum weight design problem for the structure, but also the suppression problem of the effect of disturbances for the control system as the purpose of the design. A numerical example shows the validity of combined optimal design of the structure and control systems. We also consider the validity of the sensor-actuator collocation for the control system design in this paper.

Effect of Myricetin Combined with Taurine on Antioxidant Enzyme System in B16F10 Cell (Myricetin과 Taruine의 병용 투여가 B16F10 세포의 항산화 효소계에 미치는 영향)

  • Yu, Ji-Sun;Kim, An-Keun
    • YAKHAK HOEJI
    • /
    • v.50 no.1
    • /
    • pp.58-63
    • /
    • 2006
  • The antioxidant enzyme (AOE) system plays an important role in the defense against oxidative stress damage. To determine whether myricetin or myricetin/taurine can exert antioxidative effects not only by modulating the AOE system directly but also by scavenging free radical, we investigated the influence of the myricetin and taurine on cell viability ROS level, activities of different antioxidant enzyme, and the expression of different antioxidant enzyme. As results, the cell viability showed inhibition of the proliferation with treatment of 'myricetin' or 'myricetin with taruine', respectively, with dose-dependent manner. Compared to control, the treatment of 'myricetin' decreased activities and gene expressions of superoxide dismutase (SOD), and glutathione peroxidase (GPx). However, combined treatment of 'myricetin with taurine' increased activities and gene expressions of the SOD, GPx, and catalase (CAT). In addition, the combined treatment of 'myricetin with taurine' somewhat decreased ROS levels, compared to the treatment of 'myricetin'. In conclusion, our study provides that the combined treatment of different antioxidants can enhance antioxidant effects.

Rotational Characteristics of High Precision Spindle Unit with Ball-Hydrostatic Bearing (볼-유정압 복합베어링을 갖는 고정밀 주축의 회전특성에 관한 연구)

  • 이찬홍;이후상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.663-667
    • /
    • 2000
  • The spindle unit is core parts in high precision machine tools. Diverse static and dynamic charateristics of spindle unit are needed for special purpose of machine tools. Specially, high damping ability may be very useful to high precision and high speed spindle unit. But commercial bearing system has very low damping value and high stiffness. In this paper, the combined bearing system with ball-hydrostatic bearing is suggested for high damping spindle unit. The suggested bearing system has 30% damping ability more than general ball bearing's. The average rotational accuracy of spindle with combined bearing in working speed is 24% better than with ball bearing. The unbalance rotating experiment in spindle show that rotating error with combined bearing is only half value of with ball bearing.

  • PDF

Multi-Objective Optimization of Rotor-Bearing System with dynamic Constraints Using IGA

  • Choi, Byung-Gun;Yang, Bo-Suk;Jun, Yeo-Dong
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.403-410
    • /
    • 1998
  • An immune system has powerful abilities such as memory recognition and learning how to respond to invading antigens, and has been applied to many engineering algorithms in recent year. In this paper, the combined optimization algorithm (Immune-Genetic Algorithm: IGA) is proposed for multi-optimization problems by introduction the capability of the immune system that controls the proliferation of clones to the genetic algorithm. The new combined algorithm is applied to minimize the total weight of the rotor shaft and the transmitted forces at the bearings in order to demonstrate the merit of the combined algorithm. The inner diameter of the shaft and the bearing stiffness are chosen as the design variables. the results show that the combined algorithm can reduce both the weight of the shaft and the transmitted forces at the bearing with dynamic constraints.

  • PDF

Structure-Control Combined Design for 3-D Flexible Structure (3차원 유연구조물에 대한 구조-제어 통합설계)

  • Park Jung-Hyen
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.109-114
    • /
    • 2004
  • A combined optimal design problem of structural and control systems is discussed by taking a 3-D flexible structure as an object. We consider a minimum weight design problem for structural system and disturbance suppression problem for the control system. The conditions for the existence of controller are expressed in terms of linear matrix inequalities (LMI). By minimizing the linear sum of the normalized structural objective function and control objective function, it is possible to make optimal design by which the balance of the structural weight and the control performance is taken. We showed in this paper the validity of combined optimal design of structural and control systems.

Seismic Performance of Replaceable Steel Brace System Subjected to Combined Loadings (복합하중을 고려한 교체 가능한 강재 브레이스 시스템의 내진성능)

  • Ro Kyong Min;Kim Yoon Sung;Kim Min Sook;Lee Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.4
    • /
    • pp.43-50
    • /
    • 2023
  • This study aims to assess the seismic performance of retrofitted reinforced concrete columns using a Replaceable Steel Brace (RSB) system, subjected to combined axial, lateral, and torsional loadings. Through experimental testing, one non-retrofitted concrete column specimen and two retrofitted specimens with variable sliding slot lengths were subjected to eccentric lateral loads to simulate realistic seismic loading. The retrofitted specimens with RSBs exhibited enhanced resistance against shear cracking, effective torsional resistance, and demonstrated the feasibility of easy replacement. The RSB system substantially improved seismic performance, achieving approximately 1.7 times higher load capacity and 3.5 times greater energy dissipation compared to non-retrofitted column, thus validating its efficacy under combined loading conditions.

Evaluation of First Flush Rainfall Inflow and Pollution Loads into Manhole against Combined and Sanitary Sewer Overflows (초기우수 관거유입계수 산정 및 오염부하 기여도 평가)

  • Kim, Hongtae;Shin, Dongseok;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.67-70
    • /
    • 2015
  • Some data into combined and sanitary sewer system were collected in order to find out the characteristics of discharge from first flush rainfall inflow. The inflow ratios of combined and sanitary sewer system were 0.46 and 0.27 during rains from various survey data. The average inflow ratio 0.31 was appropriate for general application because many watersheds were not classified clearly as combined or sanitary sewage treatment areas. The percentage of first flush loads in the whole BOD load was about 10%. This result was thought some meaningful, comparing with similarity of first flush pollution load contribution previous surveyed by KECO (2004).