• 제목/요약/키워드: combined noise sources

검색결과 41건 처리시간 0.022초

수면방해에 대한 복합소음의 종류와 S/N비의 영향 (Effect of Type and S/N Ratio of Combined Noise Sources on Sleep Disturbance)

  • 이평직;심명희;전진용
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.960-966
    • /
    • 2009
  • The World Health Organization(WHO) has reported the sleep disturbance as one of the adverse effects of noise. And the effect of combined noise sources on human have been investigated because community noises are seldom heard and are concurrent. Therefore, the effects of combined noise source and its S/N ratio on sleep disturbance were investigated; as a single noise source, road traffic noise was selected, and construction and movie noise were combined with road traffic noise. Tests for sleep disturbance were conducted in bedrooms and the effect on each subjects' sleep was evaluated by questionnaire. The results showed that the rate of awakening increased slightly only when the SPL of construction noise was 10 dB higher than that of road traffic noise. It was also found that the sleep disturbance was affected by the type of combined noise sources and its S/N ratio.

외부 공간에서 복합소음에 대한 불쾌감 연구 (Dose-response relationship for annoyance caused by combined noise sources in urban spaces)

  • 이평직;유진;정충일;연준오;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.264-267
    • /
    • 2008
  • Relationship between exposure to combined noise sources and community annoyance have been investigated. Social surveys were conducted in urban spaces near the construction site with road traffics. The question relating to noise annoyance was answered on an 11-point numerical scale and 5-point verbal scale according to ISO 15666. The questionnaire also contained demographic factors, interference with daily activities, health-related symptoms, and noise sensitivity. Noise levels were measured in terms of A-weighted equivalent level ($L_{Aeq}$), and noise mapping technique was applied to predict the noise levels of urban spaces. Synthesis curves for the relationship between noise levels and percentage highly annoyed for combined noise sources were derived, and compared to the curves from a single noise source.

  • PDF

1200MW 복합화력 발전소가 부지경계에 미치는 환경소음 예측 (Environmental Noise Evaluation of the Boundary Areas for 1200MW Combined Cycle Power Plant)

  • 이현;김연환;김희수;배용채;김성휘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1056-1061
    • /
    • 2001
  • This paper describes the evaluation of noise influence of residental and boundary areas from power plant noise sources of 1200MW combined cycle power plant. Noise assessments are carried out by based on the ISO 3744, ISO 9613-1 and ISO 9613-2 to predict the noise distribution to satisfy the recommended noise level at specific locations and to calculate properly the octave noise power of main noise sources such as power transformers. air-intakes, stacks.

  • PDF

산업용 직각형 감속기의 소음 저감에 대한 연구 (A Study on Noise Reduction for an Industrial Right-angled Reducer)

  • 서홍승;박성필;정진태
    • 한국소음진동공학회논문집
    • /
    • 제21권6호
    • /
    • pp.546-552
    • /
    • 2011
  • In this study, noise sources of a reducer which is combined a spiral bevel gear and a planocentric gear are identified by experimental method and the noise was reduced by the structure modification of the reducer. In order to identify the noise sources, noise and vibration signals were measured by microphone and accelerometer and these signals were analyzed with waterfall plot. In addition, the frequency response functions were obtained to prove the noise and vibration sources. It was found that the resonance was generated by the gear mesh frequencies and natural frequency of the reducer. The noise of the reducer could be reduced by structure modification.

산업용 직각형 감속기의 소음 저감에 대한 연구 (A Study on Noise Reduction for the reducer designed right angle)

  • 서홍승;박성필;정진태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.51-56
    • /
    • 2011
  • In this study, noise sources of a reducer which is combined a spiral bevel gear and a planocentric gear are identified by experimental method and the noise was reduced by the structure modification of the reducer. In order to identify the noise sources, noise and vibration signals were measured by microphone and accelerometer and these signals were analyzed with waterfall plot. In addition, the frequency response functions were obtained to prove the noise and vibration sources. It was found that the resonance was generated by the gear mesh frequencies and natural frequency of the reducer. The noise of the reducer could be reduced by structure modification.

  • PDF

진공청소기 원심 홴의 소음원 분석 및 공력 소음 예측 (Investigation of the noise sources for the centrifugal fan and aeroacoustic noise prediction)

  • 정예은;배영민;문영준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.645-645
    • /
    • 2009
  • In many practical applications of the centrifugal fan, the impeller-diffuser interaction noise is considered as a main source of fan noise. The housing for an electric motor is also expected to play an important role on noise propagation because of its complicated configuration. This study investigates the impeller-diffuser interaction noise and its sources by computing three-dimensional, incompressible flow field of the centrifugal fan in motor housing. The effect of motor case on fan noise characteristic is then investigated using the Brinkman penalization method, while the noise source associated with impeller-diffuser interaction is mathematically modeled. It is found that the present methodology combined with mathematical description of noise source provides a fairly good agreement with the experimental results, indicating that the motor housing has significant effect on noise characteristics. Finally, aeroacoustic noise prediction for various impeller-diffuser blade count ratios is conducted for noise reduction.

  • PDF

발전소 변압기 소음저감 대책의 유효성 (The effectiveness of noise reduction devices for transformer noise control of Power Plants)

  • 김연환;김희수;배용채;이현;김성휘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1823-1828
    • /
    • 2000
  • Power transformers, air-intakes, stacks in a combined thermal power plant are the main noise sources. Power transformer noise among them has being get a target of public complaint due to 480Hz component of its pure tone. The source is mainly magnetostrictive vibration of the transformer core. The first countermeasures was installing sound barrier on the front of transformer. However, 500Hz, center of the frequency is not reduced. This paper includes the measurements of noise level at the near resident apartment, the identification of noise transfer and the countermeasures for noise sources. Cavity resonance type of noise reduction devices was installed on enclosuring wall of transformers. As a result, the noise level from transformer is reduced about 3dB.

  • PDF

다차원 스펙트럼 해석법을 이용한 탈수 시 드럼세탁기의 소음 기여도 분석 (The Analysis of Noise Contribution about Drum Washer under Dehydrating Condition Using Multi-dimensional Spectral Analysis)

  • 김호산;박상길;강귀현;이정윤;오재응
    • 한국소음진동공학회논문집
    • /
    • 제17권11호
    • /
    • pp.1056-1063
    • /
    • 2007
  • Recently, there has been a growing consumer interest in the amount of noise produced by household electrical appliances. The designer of the product must identify the source of the noise, in order to reduce the noise. In the case of a household electric appliance such as the washing machine, there is consumer's complaint about the noise that is generated during the dehydrating condition. Because of several noise sources combined each other. It is difficult to identify the noise sources that contribute to the noise output. Multi-Dimensional Spectral Analysis (MDSA) is a method that can remove the correlation between different noise sources, and it expresses the key contributing factor as a unique output. This study utilized MDSA to analyze the contribution of each input in the noise output during the dehydrating condition.