• Title/Summary/Keyword: combined management system

Search Result 611, Processing Time 0.025 seconds

A Study on the Installation of Combined Turnout Management System (분기기 통합 관리 시스템 구축에 관한 연구)

  • Kong, Hyun-Jin;Kim, Doo-Guym;Ko, Young-Hwan;Song, Joong-Ho;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1077-1083
    • /
    • 2011
  • Turnout is one of railroad track components. The turnout is used to change train routes to near other sections when keeping the train speed. There are many accidents in the section including the turnout. The number of accidents and errors is 363 for ten years in the section including the turnout and annual average is 36.3. To ensure safety of the turnout, it is necessary to install monitoring systems. By using the monitoring systems, it is able to accumulate related information, develop maintenance and take a step for accidents in advance. Hence, The number of accidents and errors is decreased in the section including the turnout. So, when new turnout is installed, it is needed to use monitoring systems. Therefore, combined turnout management system is needed in Korea. It is possible to perform efficient maintenance because real-time monitoring system by using sensors and data-base management system. In this paper, accidents in the section including domestic turnout are analyzed and foreign combined turnout management system is presented. Hence, articles for installing the combined turnout management system in Korea are proposed.

  • PDF

Evaluation of First Flush Rainfall Inflow and Pollution Loads into Manhole against Combined and Sanitary Sewer Overflows (초기우수 관거유입계수 산정 및 오염부하 기여도 평가)

  • Kim, Hongtae;Shin, Dongseok;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.67-70
    • /
    • 2015
  • Some data into combined and sanitary sewer system were collected in order to find out the characteristics of discharge from first flush rainfall inflow. The inflow ratios of combined and sanitary sewer system were 0.46 and 0.27 during rains from various survey data. The average inflow ratio 0.31 was appropriate for general application because many watersheds were not classified clearly as combined or sanitary sewage treatment areas. The percentage of first flush loads in the whole BOD load was about 10%. This result was thought some meaningful, comparing with similarity of first flush pollution load contribution previous surveyed by KECO (2004).

A study on the construction of a combined system of western and oriental medicine at the Korean National Rehabilitation Center (국립재활원 양.한방 협진체계 구축에 대한 소고)

  • Lim, Sung-Min
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Objectives This study investigates the construction of a combined system of Western and Oriental medicine at the Korean National Rehabilitation Center. The findings of this study can be used as guidelines for the establishment and management of an Oriental Medicine Department at the Center. Methods The study involved the collection and organization of information regarding combination of Western and Oriental medicine, analysis of the current system, meetings with experts, modifications made on the basis of the meeting results, and assessment of operations to be carried out by the Oriental Medicine Department at the Center. Results This study provided suggestions for the establishment and management of the Oriental Medicine Department at the Center. In addition, it made recommendations for the role that the Oriental Medicine Department can play in the formation of a combined system of Western and Oriental medicine. Thus, the study can facilitate the construction of a combined system of Western and Oriental medicine through the Oriental Medicine Department at the Center in December 2010. Conclusion It is possible to realize patient-centric treatment procedure under the stable and efficient combination of Western and Oriental medicine through the establishment of an Oriental Medicine Department at the Korean National Rehabilitation Center. Such a cooperative system should involve a complete understanding of Western and Oriental medicine and should not be restricted to limited information sharing.

A Study on the outcome-oriented evaluation using System Dynamics: Focused on the Field of Disaster and Safety Management in the Combined Evaluation of Local Governments (SD를 활용한 성과지향적 평가에 관한 연구: 자치단체 합동평가 재난안전분야를 중심으로)

  • Kim, Kun Wee;Choi, In Soo;Jeon, Dae Uk
    • Korean System Dynamics Review
    • /
    • v.14 no.4
    • /
    • pp.143-163
    • /
    • 2013
  • This study is firstly aiming at diagnosing the present problems of evaluating the performance, especially in the field of disaster and safety management, of LGA (Local Government Authorities) in Korea. The study also deals with developing alternatives to solve a series of barrier factors revealed during the evaluation process using System Dynamics. This paper therefore presents literature review including the official documents published by the government and the performance evaluation studies of LGA. Moreover the authors analyze the current practice of the CELG (Combined Evaluation of Local Governments) as performance management, address and map a series of barrier factors in the CELG process to elaborate the CLDs (Causal-Loop Diagrams) and find solutions using system thinking with the CLDs. According to the analysis results, the core barrier factors to overcome is lack of proactive indicators/indices in the current practice of the CLEG. The authors therefore recommend to develop more proactive indicators that leads to avoid difficulties in measuring the LGA output, as well as to lessen the burden in competition for rankings and goal of the displaced.

  • PDF

Effect of Drainage System on ET and Drainage Flows

  • ;Ph.D.,P.E.
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.E
    • /
    • pp.12-19
    • /
    • 1992
  • The effects of drainage system on evapotranspiration and drainage flows are studied. Data from drainage field experiment at Castalia in North Central Branch, Ohio Agricultural Research and Development Center were used in this study. A water table management model, ADATP (Agricultural Drainage and Pesticide Transport), which was developed by combining the GLEAMS and the subsurface drainage part of the DRAINMOD model with several modifications, was evaluated and used to predict hydrologic components. The ET is very much affected by the presence of tile drainage system but not significantly affected by the surface drainage system. The combined surface and subsurface drainage system gives the largest total outflow values while the surface drainage only system gives the smallest. Comparisons of model predicted and measured values of surface runoff only, subsurface drainage only, and combined surface runoff and subsurface drainage system are in satisfactory agreement. The model predicted values are within the range of the variations of the observed replications in general. Based on the results of the model evaluation study, it is concluded that ADAPT model can be used to design water table management systems.

  • PDF

A Study on the ESS Integration Plan with Inner PCS of Wave-Offshore Hybrid Generation System for Maximizing Power Profile Stability (복합발전의 공급전력 안정성 극대화를 위한 파력발전 PCS의 BESS 연동방안 연구)

  • Jung, Seungmin;Kim, Hyun-Wook;Yoo, Yeuntae;Jang, Gilsoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.82-91
    • /
    • 2014
  • The combined generator system by integrating several renewable energy sources can share the electrical infrastructure and therefore have the advantage of constructing not only the transmission system but also the power conversion system. Among the various combined renewable system, the wind power and wave power has a high possibility of future growth due to the economic feasibility in offshore environment. This kind of large-scale combined systems might be follow the determination by the transmission system operator's directions and control the output profile by focusing at PCC. However, both renewable energies are depend on the unpredictable environmental variation; it is needed to do the compensation devices. In this paper, the ESS compensation plan is proposed to do output determination of the combined generator system by paying attention to active power of utility grid with the analysis of the controllable elements of the wind and wave power generator. The improvement of the new application technique of the combined system is confirmed through using the PSCAD/EMTDC. The entire simulation process was designed by adopting the active power control according to the reference signal of TSO.

Analysis of the Effects of Sewer System on Urban Stream using SWMM based on GIS (GIS 기반의 SWMM 모형을 이용한 하수도시스템 선정에 따른 도시하천 수질개선효과의 정량적 분석)

  • Jang, Ju-Hyoung;Park, Hae-Sik;Park, Chung-Kil
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.982-990
    • /
    • 2006
  • Generally CSOs (Combined Sewer Overflows) are regarded as one of the most serious nonpoint pollution source in the urban watershed, Particularly, the water quality of the Oncheon stream is seriously affected by CSOs because the capacity of interception sewer system connected to the Suyoung wastewater treatment plant is too small to intercept most storm water discharges. The objective of this study is to evaluate the effect of nonpoint source on an urban stream with regards to combined sewer system and separate sewer system using GIS (Geographic Information System) and SWMM (Storm Water Management Model), and to provide an insight for the management of urban stream water quality. In order to consider the effect of CSOs on the receiving water quality, the flow divider element in SWMM was applied. The model calibration and verification were performed by the measured data of quantity and quality on the Oncheon stream. The quantity data acquired from the Suyoung wastewater treatment plant were also used for this procedure. In case of separate sewer system, the modeling results showed the increased tendency in streamflow compared with the combined system in dry weather, In addition, the water quality is remarkably improved in rainfall events at the separate condition. The results imply that the construction of separate sewer system should be taken into first consideration to restore the quality and quantity of water in urban streams.

A Study on the Analysis of Publicly Announced Combined Financial Statements and their Improvement Points (공시된 결합재무제표의 분석과 게선 방향에 관한 연구)

  • Park Sang-Bong
    • Management & Information Systems Review
    • /
    • v.6
    • /
    • pp.137-162
    • /
    • 2001
  • Our business conglomerates are sharing their fates economically because of mutual debt warranty among their own affiliates and excessive financial loans. For this reason, it is inevitably restrictive to obtain the whole information on such conglomerates by individual and consolidated financial statements. To solve this problem, the system of combined financial statement was introduced through modifications of the Act of the outside audit of corporations in 1988. As a result, 15 out of this nation's 30 major business conglomerates prepared and submitted their own combined financial statements. In this paper, all financial statements are grouped into financial and non-financial parts, based on characteristics of business control and combined financial statement. Then the business size, financial rate and internal transactions for each of the conglomerates are analyzed, based on which problems of the combined financial statement as announced publicly are clarified. For the system, this study suggests improvement points such as a sufficient publication of any possible situations and interest coordination caused between the date of business settlement and that of preparing combined financial statements by applying principles of sharing to the evaluation of valuable instrument papers for investment and by determining the amount, 5% accounting for the total amount of debt warranty, foreign exchange assets and debts.

  • PDF

Optimization Model for Location Management in WCDMA Networks (WCDMA 네트워크에서의 일치관리 최적화 모형)

  • Chung, Yong-Joo
    • Korean Management Science Review
    • /
    • v.26 no.3
    • /
    • pp.23-35
    • /
    • 2009
  • This study deals with the location management in WCDMA (Wideband Code Division Multiple Access) networks. The new location management method is the one of the many techniques used to provide the packet switched (PS) services effectively in WCDMA networks. WCDMA introduces RA (routing area) for the PS services in addition to LA (location area) for the circuit switched (CS) services. WCDMA system also adopts the cooperative paging and the combined area update which are to decrease signaling traffic using the PS network resources for the CS services. Considering the characteristics of the WCDMA networks, this study formulate into the mathematical programming problem for the location management. Rather than the existing researches which consider the single MSC/SGSN networks, we deal with the multi MSC/SGSN networks, where both MSC area and SGSN area should be determined as well. Fairness between traffic loads of MSC/SGSN and the system cost incurred to MSC/SGSN are also incorporated into our model, which make the model more realistic. We propose greedy algorithms for the problems, which consists of the merger of two neighboring areas and the movement of an area. Extensive experiment has been done based on the realistic problem examples. Followed by the analysis of parameter effect on the final solutions and the quality of final solutions obtained by our greedy algorithms. Our proposed model and analysis result can be used to determine WCDMA system areas and to predict the system performance measures by the determination.

Energy Management Technology Development for an Independent Fuel Cell-Battery Hybrid System Using for a Household (가정용 독립 연료전지-배터리 하이브리드 에너지 관리 기술 개발)

  • YANG, SEUGRAN;KIM, JUNGSUK;CHOI, MIHWA;KIM, YOUNG-BAE
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.2
    • /
    • pp.155-162
    • /
    • 2019
  • The energy management technology for an independent fuel cell-battery hybrid system is developed for a household usage. To develop an efficient energy management technology, a simulation model is first developed. After the model is verified with experimental results, three energy management schemes are developed. Three control techniques are a fuzzy logic control (FLC), a state machine control (SMC), and a hybrid method of FLC and SMC. As the fuel cell-battery hybrid system is used for a house, battery state of charge (SOC) regulation is the most important factor for an energy management because SOC should be kept constant every day for continuous usage. Three management schemes are compared to see SOC, power split, and fuel cell power variations effects. Experimental results are also presented and the most favorable strategy is the state machine combined fuzzy control method.