• Title/Summary/Keyword: combined electric power generation system

Search Result 48, Processing Time 0.028 seconds

Analysis on the Operational Characteristics of the Combined Generation System with Power Storage Apparatus that Apply Microcontroller

  • Lim, Jung-Yeol;Yoon, Seok-Am;Cha, In-Su
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.12B no.1
    • /
    • pp.24-30
    • /
    • 2002
  • The developments of the solar and the wind power energy are necessary since the future alternative, energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a flew faults with the weather condition. In order to solve these existing problem combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added far the present study. In an experiment, when output of combined generation system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

Development of kW Class SOFC Systems for Combined Heat and Power Units at KEPRI

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Keun-Bae;Yoo, Young-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.12
    • /
    • pp.772-776
    • /
    • 2008
  • The Korea Electric Power Research Institute (KEPRI) has been developing planar solid oxide fuel cells (SOFCs) and power systems for combined heat and power (CHP) units. The R&D work includes solid oxide fuel cell (SOFC) materials investigation, design and fabrication of single cells and stacks, and kW class SOFC CHP system development. Anode supported cells composed of Ni-YSZ/FL/YSZ/LSCF were enlarged up to $15{\times}15\;cm^2$ and stacks were manufactured using $10{\times}10\;cm^2$ cells and metallic interconnects such as ferritic stainless steel. The first-generation system had a 37-cell stack and an autothermal reformer for use with city gas. The system showed maximum stack power of about $1.3\;kW_{e,DC}$ and was able to recover heat of $0.57{\sim}1.2\;kW_{th}$ depending on loaded current by making hot water. The second-generation system was composed of an improved 48-cell stack and a prereformer (or steam reformer). The thermal management subsystem design including heat exchangers and insulators was also improved. The second-generation system was successfully operated without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_{e,DC}$ with hydrogen and $1.2\;kW_{e,DC}$ with city. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water. Recently KEPRI manufactured a 2kW class SOFC stack and a system by scaling up the second-generation 1kW system and will develop a 5kW class CHP system by 2010.

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • New & Renewable Energy
    • /
    • v.2 no.3
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

The policy study on the power grid operation strategy of new and renewable energy combined generation system (도서지역의 신재생에너지복합발전 전력계통 운영방안에 관한 정책연구)

  • Kim, Eui Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.109.1-109.1
    • /
    • 2011
  • KEPCO was operating power plants with diesel generators in 49 islands including Baekryeong-Do, and the generation capacity was about 66 MW in 2008. The cost of fuel is increasing by the international oil price inflation and continuous rise of oil price is predicted. For the stabilizing of electric power supply to the separate islands, renewable energy and fuel cell systems were considered. Hydrogen is made using renewable energy such as wind power and solar energy, and then a fuel cell system generates electricity with the stored hydrogen. Though the system efficiency is low, it is treated as the only way to secure the stable electric supply using renewable energy at this present. The analytic hierarchy process was used to select suitable candidate island for the system installation and 5 islands including Ulleung-Do were selected. Economic evaluation for the system composed of a kerosene generator, a wind power, an electrolysis, and a fuel cell system was conducted with levelized generation cost based on present value methode. As the result, the necessity of renewable energy combined generation system and micro grid composition in the candidated islands was confirmed. Henceforth, the development of an integration technology which connects micro grid to the total power grid will be needed.

  • PDF

A Combined Bulk Electric System Reliability Framework Using Adequacy and Static Security Indices

  • Billinton, Roy;Wangdee, Wijarn
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.414-422
    • /
    • 2006
  • Deterministic techniques have been applied in power system planning for many years and there is a growing interest in combining these techniques with probabilistic considerations to assess the increased system stress due to the restructured electricity environment. The overall reliability framework proposed in this paper incorporates the deterministic N-1 criterion in a probabilistic framework, and results in the joint inclusion of both adequacy and security considerations in system planning. The combined framework is achieved using system well-being analysis and traditional adequacy assessment. System well-being analysis is used to quantify the degree of N-1 security and N-1 insecurity in terms of probabilities and frequencies. Traditional adequacy assessment is Incorporated to quantify the magnitude of the severity and consequences associated with system failure. The concepts are illustrated by application to two test systems. The results based on the overall reliability analysis framework indicate that adequacy indices are adversely affected by a generation deficient environment and security indices are adversely affected by a transmission deficient environment. The combined adequacy and security framework presented in this paper can assist system planners to realize the overall benefits associated with system modifications based on the degree of adequacy and security, and therefore facilitate the decision making process.

Performance Test of MGT Combined Heat & Power System (마이크로 가스터빈 열병합 발전시스템 성능평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

A Development of the Software to Estimate of Economics for Combined Heat and Power Generation Systems in Apartment Estates (아파트의 소형열병합발전시스템 경제성평가 프로그램개발)

  • Lee, Jong-Sung;Park, Tae-Won;Lee, Taik-Seob
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.89-94
    • /
    • 2006
  • For a development of the software which estimates the economics of a combined heat and power generation system in apartment estates, the thermal consumption and electric power consumption data were investigated in about 115 apartment estates. And the algorithm was developed, then the software was made by the macro function of the Excel spread sheets.

  • PDF

Analysis on the Operation Characteristic of the Combined Electric Power Generation System by Photovoltaic and Wind Energy with Power Storage Apparatu (동력저장장치를 이용한 풍력$\cdot$태양광 복합발전시스템의 특성분석)

  • Lim Jung-Yeol;Lee Jung-Il;Jung Hak-Su;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.58-62
    • /
    • 2001
  • Photovoltaic and wind power generation have an advantage of unlimited and unpolluted amount of energy resource. In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. The system driven by the wind force in this paper consists of a generator, an invertor, batteries and sets for power storage with a spring. In this paper, the operation characteristics of system were analyzed through experiments for a trial product.

  • PDF

Combined Propulsion System Analysis for Naval Combatant Vessels using Diesel and Gas Turbine Engine (디젤 및 가스터빈 엔진을 사용하는 전투함의 복합추진체계 기술 동향 분석)

  • Lee, H.M.
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.16-21
    • /
    • 2011
  • The large scale decisive battle will be gradually reduced on the sea in the future and surface combatant ship installed advanced weapon units as well as propulsion system will be continuously increased. The high level of military technology leads to appear state-of-the-art weapon system using high power energy. As a results, fossil fuel powered main prime mover as diesel engine and gas turbine which are composed of mechanical propulsion system should be decreased from combatant ship in the near future. The new building naval combatant ship with the latest technology has electric based propulsion method of the hybrid type combined with mechanical and electrical drive. U.S. and Royal Navy, especially, select the integrated fully electric based propulsion system for the next generation combat ship and play an important roll for developing them. In this context, this paper was focused on the deduction of implications through analyzing the combatant ship propulsion system using diesel and gas turbine engine which are promoted on the worldwide.