• Title/Summary/Keyword: combination tests

Search Result 720, Processing Time 0.041 seconds

Behavior of High-Speed Rail Roadbed Reinforced by Geogrid under Cyclic Loading (지오그리드로 보강한 고속철도 노반의 거동 특성)

  • 신은철;김두환
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.84-91
    • /
    • 2000
  • The general concept of reinforced roadbed in the high-speed railway is to cope with the soft ground for the bearing capacity and settlement of foundation soil. The cyclic plate load tests were performed to determine the behavior of reinforced ground with multiple layers of geogrid underlying by soft soil. With the test results, the bearing capacity ratio, elastic rebound ratio, subgrade modulus and the strain of geogrids under loading were investigated. Based on these plate load tests, laboratory model tests under cyclic loading were conducted to estimate the effect of geogrid reinforcement in particular for the high-speed rail roadbed. The permanent settlement and the behavior of earth pressure in reinforced roadbed subjected to a combination of static and dynamic loading are presented.

  • PDF

The behavior of high-speed rail roadbed reinforced by geogrid under cyclic loading (지오그리드로 보강한 고속철도 노반의 동적 거동)

  • 신은철;김두환;김종인
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.415-422
    • /
    • 1999
  • The general concept of reinforced roadbed in the high-speed railway is to cope with the soft ground for the bearing capacity and settlement of foundation soil. The cyclic plate load tests were performed to determine the behavior of reinforced ground with multiple layers of geogrid underlying by soft soil. Five series of test were conducted with varying the soil profile conditions including the ground level, type of soil, and the thickness of each soil layer. Based on these plate load tests, laboratory model tests under cyclic loading were conducted to know the effect of geogrid reinforcement in particular for the high-speed rail roadbed. The permanent settlement and the behavior of earth pressure in reinforced roadbed subjected to a combination of static and dynamic loading are presented.

  • PDF

Perceptibility and Acceptability Tests for the Quality Changes of Complex Images (복합 이미지에 대한 Perceptibility와 Acceptability 측정)

  • Kim Dong Ho;Park Seung Ok;Kim Hong Seok;Kim Yeon Jin
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.80-81
    • /
    • 2003
  • The psychophysical experiments were carried out by a panel of eleven observers on the image difference pairs displayed on the LCD (liquid crystal display)to quantify the quality changes of complex images imparted by the typical image processing operations. There were six different kinds of pairs according to their original image. The three types of visual tests performed were: pair-to-pair comparison of image differences for ordering the differences between images introduced by single or combination of image lightness change, contrast change, blurring, and sharpening, perceptibility and acceptability tests using ascending or descending series of image difference pairs ordered according to the size of their visual differences. (omitted)

  • PDF

Performance Test of C-shape Steel Base Isolation System (C형 강재 지진격리장치의 성능시험)

  • Jung, Dae-Yu;Shim, Chul-Hwan;Park, Hyung-Ghee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.25-35
    • /
    • 2009
  • This paper introduces the performance of a newly developed base isolation system made from the combination of a polyurethane disk - attached pot bearing and C-shape steel dampers. Ultimate compressive load tests, ultimate rotation tests, dynamic tests, and dynamic load repeat tests have been completed to determine dynamic characteristics and to verify performance characteristics. The experimental results are compared with the analytic results. It is determined that all requirements for bridge bearing in the specifications are satisfied, and that adequate energy dissipation has occurred. The EDC and effective stiffness estimated by tests are similar to the theoretical values.

Enhancement of Antinociception by Co-administrations of Nefopam, Morphine, and Nimesulide in a Rat Model of Neuropathic Pain

  • Saghaei, Elham;Zanjani, Taraneh Moini;Sabetkasaei, Masoumeh;Naseri, Kobra
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2012
  • Background: Neuropathic pain is a chronic pain due to disorder in the peripheral or central nervous system with different pathophysiological mechanisms. Current treatments are not effective. Analgesic drugs combined can reduce pain intensity and side effects. Here, we studied the analgesic effect of nimesulide, nefopam, and morphine with different mechanisms of action alone and in combination with other drugs in chronic constriction injury (CCI) model of neuropathic pain. Methods: Male Wistar rats (n = 8) weighing 150-200 g were divided into 3 different groups: 1- Saline-treated CCI group, 2- Saline-treated sham group, and 3- Drug-treated CCI groups. Nimesulide (1.25, 2.5, and 5 mg/kg), nefopam (10, 20, and 30 mg/kg), and morphine (1, 3, and 5 mg/kg) were injected 30 minutes before surgery and continued daily to day 14 post-ligation. In the combination strategy, a nonanalgesic dose of drugs was used in combination such as nefopam + morphine, nefopam + nimesulide, and nimesulide + morphine. Von Frey filaments for mechanical allodynia and acetone test for cold allodynia were, respectively, used as pain behavioral tests. Experiments were performed on day 0 (before surgery) and days 1, 3, 5, 7,10, and 14 post injury. Results: Nefopam (30 mg/kg) and nimesulide (5 mg/kg) blocked mechanical and thermal allodynia; the analgesic effects of morphine (5 mg/kg) lasted for 7 days. Allodynia was completely inhibited in combination with nonanalgesic doses of nefopam (10 mg/kg), nimesulide (1.25 mg/kg), and morphine (3 mg/kg). Conclusions: It seems that analgesic drugs used in combination, could effectively reduce pain behavior with reduced adverse effects.

Fire Tests for Representative Combustibles in Residential Facilities for the Development of Field Commander Training Content (현장지휘관 훈련 콘텐츠 개발을 위한 주거목적시설 대표 가연물 실물화재시험)

  • Moon, Min-Ho;Yang, So-Yeon;Han, Kuk-Il;Lee, Ji-Hee;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, the fire patterns, heat emissions, and smoke generated by means of fire tests developed for representative combustibles in residential facilities were analyzed from among seven fire types. These combustibles were selected in a previous study to simulate real-world situations and professionalism required while dealing with these types of fires and develop the field commander training content. Consequently, the maximum heat dissipation was recorded as 728.6 kW, followed by the dissipation measured from the combination of a mattress and electric blanket, desk and chair, and TV and mattress. The total heat emission of sofas (226.2 MJ) and the combination of mattress and electric blanket (2,259.5 ㎡) was recorded. In this study, the scope of the tests was limited to the fire characteristics and characteristics of the combustibles, and it is expected that a simulation using various data acquisition methods and FDS would be performed and evaluated at a later stage.

A Study of the Effect of Magnetic Fields Using Welding Process (용접 공정에서 자기력의 효과에 대한 연구)

  • Cho, Hong Seok;Park, Ik Keun;Lee, Wooram
    • Journal of Welding and Joining
    • /
    • v.32 no.5
    • /
    • pp.32-43
    • /
    • 2014
  • Welding and joining technology has become a core field. Therefore it is more widely applied to nonferrous metals, inorganic and polymeric materials. That is because the high performance, high function and diversification trend of materials used as industrial technology develops. In the laser welding process, STS 304 and SCP1-S were used as the base materials, the output density was fixed $7MW/cm^2$, the protective gas was argon(Ar) and the transfer rate was fixed 5 mm/sec. and it was progressed while the magnetic field is gradually increasing by 100 mT ranging 0 to 400 mT. The tensile test showed in average about 6 % tensile strength improvement in the case of the laser welding process using the magnetic fields. In the shielded metal arc welding process using SPHC only or the combination of SPHC+STS304 as base materials. The electric current was set at 80 Amperes and the protective gas used argon(Ar) the same as the laser welding process and the strength of magnetic fields. In the shielded metal arc welding process using the magnetic fields, the tensile tests showed about 5 % tensile strength improvement in the case of using SPHC only, 3 % tensile strength improvement in the case of using the combination of SPHC+ STS304. In comparing the results of numerical analysis to the results of experimental tests, it was revealed that the temperature, thermal stress distribution and the behavior of molten pool were similar to those of real tests. Consequently, it may be considered that the numerical assumption and the analytical model used in this study were reasonable.

Weathering Performance Evaluation of Duplex Coating Systems of Thermal Spraying and Painting using Corrosion Test (부식실험에 의한 금속용사와 도장의 복합피복방식법의 내후성능평가)

  • Kim, In Tae;Kim, Ho Seob;Kien, Dao Duy;Jun, Je Hyeong;Ahn, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.97-108
    • /
    • 2016
  • Thermally sprayed metals or organic coatings is often used in corrosion protection of steel structures. Duplex coating systems of thermally sprayed metal in combination with organic coating are selected as a new generic type of coatings on steel structures under the highly corrosive environments. In this study, three types of corrosion tests were carried out on four types of thermal sprayed specimens with sealing: zinc, zinc-15%aluminum alloy, aluminum and aluminum-5%magnesium alloy, four types of duplex coated specimens; thermally sprayed metals in combination with paint of acrylic urethane, and painted specimens. NORSOK M-501, Wet/dry cyclic seawater tests and outdoor exposure tests of nine types of specimens were conducted. From the corrosion test results, weathering performance of them were presented.

A Case Report of Integrative Treatment in a Type 2 Diabetes Patient with Multiple Symptoms and Evaluation Using Continuous Glucose Monitoring (소갈 증상을 호소하는 제2형 당뇨 환자에서의 한양방 병행치료 치험 1례와 연속 혈당 측정기를 이용한 평가)

  • Woo-nyoung Jung;Mee-ryoung Song;Yeon-joo Yoo;Min-seong Lee;Young-min Ahn;Se-young Ahn;Byung-cheol Lee
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.303-313
    • /
    • 2024
  • Introduction: We describe the effects of Sosiho-tang decoction and insulin combination therapy, as well as the effect of integrated traditional Korean medicine therapy, using continuous glucose monitoring (CGM) in a diabetic patient complaining of a range of diabetic symptoms. Case report: A 24-year-old female presented with symptoms of diabetes, including weight loss, thirst, and polyuria, and was diagnosed with type 2 diabetes through blood tests, endocrine tests, and autoantibody tests. During hospitalization, the patient received insulin therapy and Sosiho-tang decoction concurrently, achieving normal blood glucose levels. After discharge, adhering to the Sosiho-tang decoction and CGM enabled the insulin dosage to be gradually reduced while maintaining normal blood glucose levels. Conclusion: Combination therapy with insulin and Sosiho-tang rapidly reduced hyperglycemia in the short term. CGM post-discharge allowed for observation of the patient's blood glucose levels. Ultimately, Sosiho-tang medication lowered blood glucose levels, reduced insulin requirements, and facilitated a reduction in the insulin dosage.

Diagnostic value of various screening tests in neonatal sepsis (신생아 패혈증의 다양한 선별검사들의 진단적 가치)

  • Je, Hyun Gon;Jeoung, Young Mi;Jeong, Soo Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1167-1173
    • /
    • 2006
  • Purpose : To evaluate various sepsis screening tests, individually and in combination, to formulate a guideline for the diagnosis of neonatal sepsis. Methods : The study was a retrospective cohort study. It took place at the neonatal intensive care unit of the Paediatric Department, Il Sin Christian Hospital, Busan, Korea, over a period of 68 months from 1st, April, 2001 to 31st, December, 2005. This study evaluated 100 neonates having clinical features of sepsis and 100 normal asymptomatic neonates and used screening tests including C-reactive protein (CRP), total leukocyte count (TLC), absolute neutrophil count (ANC), immature neutrophils to total neutrophil count ratio (I/T ratio), thrombocytopenia, degenerative changes in the neutrophils and gastric aspirate cytology (GAC) for the diagnosis of neontal sepsis. Results : The sensitivity of CRP and ANC was high. CRP had 86 percent sensitivity for group-A (proven sepsis) and 74 percent sensitivity for group-B (probable sepsis) and 94 percent specificity for group-A, B. ANC had sensitivity of 72 percent for group-A and 62 percent for group-B and 86 percent specificity for group-A, B. For group-A, sensitivity, specificity of GAC for polymorphs was 74 percent and 94 percent respectively. As for sensitivity, specificity of platelet count for group-A was 64 percent and 89 percent respecively. The sensitivity, specificity and predictive values (PV) of the individual tests and different test combinations were also calculated for group-A and B. Conclusion : For the detection of culture negative cases in neonatal sepsis, screening tests including CRP, TLC, ANC, thrombocytopenia, cytoplasmic vacuolization in the neutrophils and GAC for polymorphs have high sensitivity. A combination of three tests has higher sensitivity.