• Title/Summary/Keyword: column

Search Result 12,408, Processing Time 0.041 seconds

Seismic Behavior of Column-Slab Connections with Different Column Aspect Ratio (기둥 형상비에 따른 플랫 플레이트 기둥-슬래브 접합부의 거동특성)

  • Chun, Young-Soo;Lee, Hyun-Ho;Lee, Do-Bum;Kim, Jin-Soo;Hur, Moo-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.30-33
    • /
    • 2006
  • The purpose of this research is to study the seismic behavior of interior column-slab connections with different column aspect ratio, when subjected to combined gravity and cyclic lateral loading. The control specimen had square column, while the other specimens had rectangular column with aspect ratio of 0.5 and 2.0. From the test results, all of the specimens sustain lateral drifts as high as 4% with no more than a 20% decrease in peak lateral load capacity. And it appears that KBC Code(2005) procedure may be unconservative for connections with different column aspect ratio.

  • PDF

An Experimental Study for the Structural Behavior of the Precast Prestressed Concrete Columns (프리캐스트 콘크리트 교각의 구조거동에 관한 실험적 연구)

  • Choi, Seung-Won;Shin, Hyun-Mok;Lee, Jae-Hoon;Oh, Byung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.146-149
    • /
    • 2006
  • In many previous studies, a prestressed concrete column has a larger flexural strength, shear strength and restoring force than a RC column. Recently, a precast prestressed concrete column is rising up a very rational column structure in that a economic aspect. In a precast prestressed concrete column, it makes in a factory. So, it needs a small construction site and acquires a higher durability than a cast in place concrete column. Seven precast concrete columns were tested under a constant axial load and a cyclically reversed horizontal load to investigate the performance. It is designed with a hollow section and consisted of 4 segments. The main variables of the test were a amount of prestressed, a type of joints and a boding type of strands. The test results show that the performance of a precast prestressed concrete column; failure mode, maximum load, energy dissipation and stiffness degradation.

  • PDF

A study on stiffness of flat-plate system according to column section shape (기둥단면형상에 따른 무량구조시스템 강성변화에 관한 연구)

  • Kang, Su-Min;Lee, Ji-Woong;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.314-317
    • /
    • 2006
  • In the present study, design methodologies for effective width of slabs in slab-column connections were evaluated in comparison with the experimental results on the full-scale slab-column connections. The design methodologies are as follows: the methodology proposed by Jacob S. Grossman and the methodology proposed by Choi & Song. The former does not predict the stiffness change of the slab-column connection due to the change in the column section shape and the latter overestimates the stiffness when edge length of the column section in the loading direction is long. Accordingly, the equation to calculate the effective width of slabs should be modified to reflect the effect of the change in the column section shape.

  • PDF

Determination of Vitamin $B_{12}$ in Foods Using Column-Switching Technique in $\mu$-HPLC ($\mu$-HPLC의 Column-Switching 기술을 이용한 식품중 비타민 $B_{12}$의 분석)

  • 박성진;김혜경;함태식;김병용
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.6
    • /
    • pp.1208-1211
    • /
    • 1999
  • Semi HPLC using a column switching technique was used to determine the trace content of vitamin B12 in various foods. Total analytical time required less than 20 mins per sample and the recovery ratio was 99.9, 99.6, 100.1 and 99.8% for 1.0, 10.0, 100.0 and 1,000 g/kg, respectively. The content of vitamin B12 in various foods obtained using column switching method showed higher levels compared to labels in dried milk(0.5 g/100g) and in grain products(0.51~34.36 g/100g). Thus, this column switching method was more sensitive, effective and precise than the microbiological analysis currently used to determine the trace compounds like a vitamin B12.

  • PDF

A Study on the Bearing Capacity characteristics of Stone column by Numerical Analysis (수치해석에 의한 쇄석말뚝의 지지력 특성 고찰)

  • Chun, Byung-Sik;Kim, Baek-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.90-99
    • /
    • 2004
  • Stone column is one of the soft ground improvement method, which enhances ground conditions through ground water draining, settlement reducing and bearing capacity increasing complexly by using crushed stone instead of sand in general vertical drain methods. In recent, general construction material, sand is in short of supply, because of the unbalance of demand and supply. Also, the bearing capacity improving effect of stone column method is needed in many cases so the bearing capacity estimation is considered as important point. Nevertheless, adequate estimation methods to predict bearing capacity of stone column considering stone column and improving ground behavior reciprocally is not yet prepared. To contribute this situation, bearing capacity behavior of stone column were simulated as numerically on various property cases of crushed stone and surrounded ground. Through the numerical analysis of simulation results, bearing capacity behavior prediction formula was suggested. This formula was verified by comparing the prediction result with in situ test.

  • PDF

Column Shortening prediction and Field measurement of Tall building with Transfer floor (전이층을 가진 초고층건물의 기둥축소량 예측 및 현장계측)

  • Song Hwa-Cheol;Cho Yong-Soo;Chung Sung-Jin;Yoon Kwang-Sup;Lee Woo-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.175-181
    • /
    • 2006
  • The prediction of time-dependent column shortening is essential for tall buildings considering both strength and serviceability aspects. The Column shortening of tall buildings with transfer floor should be calculated considering the long-term deflection of transfer girder. In this study, both the column shortening and the deflection of transfer girder of 45-story tall concrete building are predicted. The column shortening considering deflection of transfer girder are compared with the actual column shortening by field measurement.

  • PDF

탈질 조건에서 투과매질 내 미생물 성장에 관한 연구

  • 최영화;오재일;배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.366-369
    • /
    • 2002
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Most biobarrier studies were conducted under aerobic condition, however there were several obstacles to make aerobic condition. Thus, In this study, we examined biobarrier formation under denitrifying condition by using nitrate as an electron acceptor. Experiments were performed with a sand column inoculated with activated sludge from the nearby WWTP. The substrate medium was pumped to the sand column in an upflow mode. During the low substrate loading rate period, the extent of reduction rate in hydraulic conductivity was found similar throughout the column, and permeability became relatively stable after couple of days. However, during the high substrate loading rate period, the column demonstrated a gradient of permeability reduction, with the greatest reduction in sections nearest the column inlet. Rapid growth of microorganisms near the column inlet resulted in the unbalanced reduction of hydraulic conductivity throughout the sand column. As a result, at this denitrifying condition the thickness of biobarrier could be controlled by adjusting the medium conditions of microbial growth.

  • PDF

Shear Behavior of Wide Beam-Column Joints with Slab (슬래브가 있는 넓은 보-기둥 접합부의 전단거동)

  • 안종문;최종인;신성우;이범식;박성식;양지수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.157-162
    • /
    • 2003
  • An experimental investigation was conducted to study the behavior of high-strength RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were compressive strength of concrete($f_ck$=285, 460kgf/$cm^2$), the ratio of the column-to-beam flexural capacity($M_r$=$\Sigma M_c / \Sigma M_b$ ; 0.77 -2.26), extended length of the column concrete($l_d$ ; 0, 12.5, 30cm), ratio of the column-to-beam width(b/H ; 1.54, 1.67). Test results are shown that (1) the behavior of specimen using high-strength concrete satisfied for required minimum ductile capacity according to increase the compressive strength, (2) the current design code and practice for interior joints(type 2) are apply to the wide beam-high strength concrete column.

  • PDF

Bearing capacity analysis of stone column in soft clay soils (연약점토 지반에 있는 STONE COLUMN의 지지력 산정)

  • 이윤주
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.141-148
    • /
    • 1996
  • Use of stone column for deep ground treatment in soft clay soils is an effective method. The stone column significantly increases load carrying capacity of the soft clay soil. A analysis method for bearing capacity of stone column in soft clay soil is developed. The capacity made by developed method are compared wity observed values from field load test and a reasonable correlation is noted.

  • PDF

Electrokinetic Remediation of Cobalt Contaminated Soil (코발트 오염토양 동전기적 제염)

  • 김계남;오원진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.290-293
    • /
    • 2000
  • After kaolin clay was compulsorily contaminated with Co$^{2+}$ion, the remediation characteristics by electrokinetic method were analyzed. Ethanoic buffer was injected in the soil column and $CH_3$COOH was continuously inputted in cathode reservoir to restrain the pH elevation. Since pH of the cathode side of the soil column was 4.0 at initial and was restrained by 6.5 at 43.6 hours, Precipitation, Co(OH)$_2$, was not formed in the column. Effluent rate increased with time passage and remediation in the column in initial time was mainly controlled by ion migration. 13.1% of total in the soil column was remediated in 10 hours, and the 6.8% of total in 20.8 hours, and the 71.7% of total in 43.6 hours, and the 94.6% of total in 43.6 hours. Meanwhile, the residual concentrations in the column calculated by the developed model were similar to those by experiment.t.

  • PDF