소형 칼라미터의 개발에 관한 연구 (Development of a Portable Colorimeter)

  • 김재형;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.328-331
    • /
    • 2001
  • Color simulation on a portable colorimeter was performed to distinguish quantitatively a chromaticity coordinates on a color guide of a urine strips by using the spectral power distribution of chip LED, the spectral reflectance of printed objects, and the spectral sensitivity of photodiode. The CIE tristimulus values and chromaticity coordinates realized by a colorimeter were modified to be conformable with real color reactions. Experimental results showed a real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

소형 칼라미터의 개발에 관한 연구 (Development of a Portable Colorimeter)

  • 김재형;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.328-331
    • /
    • 2001
  • Color simulation on a portable colorimeter was performed to distinguish quantitatively a chromaticity coordinates on a color guide of a urine strips by using the spectral power distribution of chip LED, the spectral reflectance of printed objects, and the spectral sensitivity of photodiode. The CIE tristimulus values and chromaticity coordinates realized by a colorimeter were modified to be conformable with real color reactions. Experimental results showed a real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

토양의 색 특성과 색차계 측정치의 상호관계 (Relationship between Soil Color Characteristics and Measurement Values by Colorimeter)

  • 김기인;홍순달
    • 한국토양비료학회지
    • /
    • 제35권2호
    • /
    • pp.77-86
    • /
    • 2002
  • 삼각통을 포함하여 29개 토양통으로 분포되는 연초 경작지 67개 토양에 대하여 토양의 색 특성은 광학적 기기에 의해 측정되는 색차계 방법과 육안관찰에 의해 비색 평가되는 Munsell color chart 방법으로 비교되었고, 또한 토양의 화학성과의 상호관계가 검토되었다. 색차계로 측정한 토양의 색 특성 L, a 및 b 값은 Munsell color chart의 명도(V), 채도(C), 및 색상(H)과 밀접하게 관련되며 정량적 수치로 표현되었다. 토양 색 측정치의 표준편차는 2mm 체 통과시료보다 0.5mm 체 통과시료에서 적었다. 토양 색의 L, 및 b 값은 수분함량이 증가함에 따라 감소되는 경향이었으나 a 값은 수분함량의 변화에 따라 차이가 없이 비슷하였다. 그러나 풍건조건과 습윤조건(-10hPa)에서 측정된 토양의 L, a, b 값 각각의 상관계수는 r=0.90 이상으로 고도로 유의성 있는 정의 상관을 보였다. 따라서 토양 색의 측정은 일정한 수분 조건인 풍건토 0.5mm 체 통과시료에서 측정하는 것이 바람직할 것으로 생각되었다. 토양의 색 특성은 유기물함량, 양이온치환용량, 치환성 석회 및 고토 등과 유의성 있는 상관을 보였으며 특히 L 값은 유기물 함량과 가장 밀접한 관계를 보였다.

New generation of imaging colorimeter and imaging polarimeter

  • Boher, Pierre;Leroux, Thierry;Glinel, David
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.453-456
    • /
    • 2009
  • We present a new generation of imaging colorimeter that ensures improved accuracy and sensitivity for shorter measurement times. The imaging optics is telecentric on the sensor and allows measurements at any distances without additional calibration. A new technology is used to make the color filters and flat densities. Imaging polarimetry at fixed wavelength is also possible with the same instrument.

  • PDF

대기 중 암모니아 성분의 분석법 연구: UV/VIS 분광계를 이용한 간이비색계의 상대 성능평가 (Some considerations for the analytical approaches to measure atmospheric ammonia: tests on a relative performance of a portable colorimeter against UV/VIS spectrophotometer)

  • 김기현;박신영;김선태
    • 분석과학
    • /
    • 제18권5호
    • /
    • pp.425-430
    • /
    • 2005
  • 본 연구에서는 대기 중 암모니아 성분의 농도 계측에 활용하는 간이비색계의 성능을 UV/VIS 분광계에 대비하는 방식으로 평가하였다. 본 연구의 목적상 두 가지 분석 시스템을 이용하여 검출한계, 재현성, 직선성, 정확도 등의 기준항목을 다양하게 비교하였다. 본 연구에 의하면, 간이비색계의 성능은 대체로 UV/VIS 분광계와 양호한 일치도를 보일 정도로 좋은 결과를 보였다. 검출한계를 평가한 결과 두 가지 시스템 모두 $3{\mu}g$에 가깝게 나타났다. 그러나 간이비색계의 경우, 아주 낮은 농도와 고농도대에서 상대적으로 문제점이 존재하는 것으로 나타났다. 예를 들어, 암모니아의 절대량이 $10{\mu}g$ 이하일 때는 재현성에 대한 문제가 두드러졌고, $100{\mu}g$ 이상의 고농도대에서는 직선성이 제한되는 문제로 인해 분석이 어려웠다. 따라서 만약 대기시료를 30 리터 정도로 채취한다고 가정하면, (별다른 희석을 가하지 않고 분석한다면) 500 ppb에서 5 ppm의 농도대에서 간이비색계를 적용하는 것이 유효한 것으로 나타났다. 농도대에 따른 간이비색계의 제한적인 특성을 충분히 감안하고 사용할 경우, 간이비색계를 활용한 분석은 상당히 양호한 결과를 생산하는 것이 가능하다는 결론을 내릴 수 있다.

Color Conversion Method for Camera-based PDP Color Inspection

  • Do, Hyun-Chul;Kim, Woo-Seop;Chien, Sung-Il;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.85-88
    • /
    • 2005
  • A low-cost and high-speed PDP color inspection system can be constructed by using a CCD camera against a colorimeter. Though the inspection can be done using RGB signals obtained by a camera, it has some difficulty to introduce human color sensitivity. Thus, it is quite desirable to convert the RGB values into the XYZ values that can be compared to the values of a colorimeter. Accordingly, the current study proposes a color conversion method that can analytically calculate the RGB-to-XYZ conversion matrix by utilizing the RGB primaries and the reference white. Experiments on Macbeth colorchecker colors showed that the average color difference between the converted XYZ values of the proposed method and the measured XYZ values of a colorimeter is much below the threshold of distinguishing two adjacent color patches.

  • PDF

White Balance를 고려한 디지털 비디오 카메라 Characterization (Digital Video Camera Characterization Considering White Balance)

  • 박종선;김대원;장수욱;김은수;송규익
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(4)
    • /
    • pp.299-302
    • /
    • 2002
  • Digital video camera can be a useful tool to capture images for use in colorimeter. However, the RGB signals generated by different digital video camera are not equal for the same scene. The digital video camera for use in colorimeter is characterized based on the CIE standard colorimetric observer. One method of deriving a colorimetric characterization matrix between camera RGB output signals and CIE XYZ tristimulus values is Polynomial modeling. In this paper, 3${\times}$3 linear matrix and 3${\times}$l1 polynomial matrix is used to investigate the characterization performance of the professional digital video camera. In experimental results, it is demonstrated that proposed 3${\times}$3 linear matrix has a reasonable degree of accuracy for use in colorimeter.

  • PDF

색차계를 이용한 방사무늬김(Pyropia yezoensis Ueda)의 황백화 평가 (Evaluation of the Discoloration of Pyropia yezoensis Ueda Using a Colorimeter)

  • 이상용;김영희;이지은;황은경
    • 환경생물
    • /
    • 제36권4호
    • /
    • pp.620-625
    • /
    • 2018
  • 김은 한국에서 가장 경제성이 높은 양식 해조류이다. 그러나 최근 김 양식장에서 발생하는 황백화 현상으로 인해 엽체의 변색과 탈락이 자주 유발되어 수산업에 큰 피해를 유발하고 있다. 이 연구는 영양염 부족에 의한 김 황백화를 간단하고 빠르게 평가할 수 있는 방법을 개발하기 위한 목적으로 수행되었다. 10일 동안 빈영양 해수에서 배양한 방사무늬김 엽체의 색도를 정량화하기 위해 색차계를 사용하였다. 색차계로 측정한 명도(L), 적색강도(a)와 노란색강도(b) 값들로 방사무늬김의 황백화를 평가하였다. 방사무늬김 엽체의 액포는 4일차부터 관측되었으며, 6일차부터 액포가 증대하였다. 색차계의 L, a와 b값은 배양시간에 따라 유의한 차이를 보였다. 명도(L)는 시간의 경과에 따라 어두움에서 점차 밝아졌다. 노란색강도 (b) 값은 시간에 따라 증가하였으나, 적색강도(a) 값은 감소하였다. 색차계의 a/b 비와 적색강도(a) 값은 방사무늬김의 색도 차이를 구분하는 주요한 요인이었다. 황백화된 방사무늬김은 명도 (L) 70 이상, 적색강도(a) 2.6 이하와 노란색강도(b) 15.0 이상의 정량적인 값으로 구분되었다. 이 연구결과 색차계는 김 황백화의 정도를 손쉽고 빠르게 진단할 수 있는 유용한 도구로 이용할 수 있음을 밝혔다.

Automated classification of display defects based on imaging colorimeter measurements

  • Kostal, Hubert;Pedeville, Gary;Rykowski, Ronald;Skelly, Sean
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1261-1264
    • /
    • 2009
  • The use of imaging colorimeter systems and associated analytical software to assess display brightness and color uniformity, contrast, and to identify defects is well established. In this paper we describe recent work to extend these methods to classify defects based on human visual perception.

  • PDF

요분석 스트립의 정색반응에 대한 색도좌표 보정 (The Compensation of Chromaticily Coordinates on Primary Color Reaction of Urine Strips)

  • 김재형;조진욱;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2001
  • A computer simulation was performed to distinguish quantitatively a color reaction in a urine analysis systems by using the spectral power distribution of LEDs, the spectral reflectance of a urine strip, and the spectral sensitivity of photodiode. The CIE tristimulus values and CIE chromaticity coordinates ware modified to be conformable with real color reactions in a urine strips. Results on color simulation showed a of real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF