• Title/Summary/Keyword: color indicator

Search Result 176, Processing Time 0.021 seconds

Development of Automatic Reading System for Steam Sterilization Indicator (스팀 멸균지시제 자동판독시스템 개발)

  • Song, Hyeok;Kim, Jeong-Rae;Lee, Woo-Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.709-714
    • /
    • 2022
  • The color change of the success of the steam sterilization indicator used in steam sterilization is currently being read by relying on the human eye. The result of color change on the success of sterilization can only be accurately read and judged by trained personnel. Developed an automatic reading system for steam sterilization indicators for the current human-dependent system, and developed an automatic reading device system for reading methods that were previously relied on with the human eye to develop a system that is more accurate and easier for anyone to read.

Studies on the Sanitary Scientific Utilization of Asphalt. Acid values determination of asphalt by improved indicator titration (아스팔트의 위생학적 이용에 관한 연구 (제 1보). 개량지시약적정법에 의한 아스팔트의 산가 측정)

  • 우세홍;김선덕;주대수
    • Journal of Environmental Health Sciences
    • /
    • v.1 no.1
    • /
    • pp.32-35
    • /
    • 1974
  • Acidic substances contained in asphalt are affect upon emulsitiability of asphalt and its adhesion with aggregates, and therfore, detemination of acidity of asphalt is of important one. However, there has not been established a method of precisely determining the acidity of asphalt. This paper reports on an improved color-indicator titration method, by which the acid number of asphalt is determined. By treating benzene solution of asphalt with alcohol, acidic constituents were selectively extracted into alcohol solution, while asphaltic matters precipitated. A color-indicator titration method then was applied to the resultant faint-colored solution. The change of color at end point was clearly observed, and the results were obtained with good reproductivity and checked well with the results by the I.P. 177/64 method. Alcohols having not more than three cabon atoms have been found suitable for extraction.

  • PDF

The Application of Humidity Indicators for Environmental Measurement Apparatus of Preservation Facility (문화재 보존시설에서의 습도지시카드 적용성 연구)

  • Lim, Bo-A;Shin, Eun-jeong;Do, Min-Hwan
    • 보존과학연구
    • /
    • s.30
    • /
    • pp.47-61
    • /
    • 2009
  • Cultural heritages are affected by various environmental factors. Main factors are temperature, humidity, light and indoor air pollutants such as ozone, nitrogen oxides. Especially humidity condition is very important. Low humidity condition can cause contraction and high humidity condition can lead to growth of microorganism. This study is conducted to appraise an applicability of the Humidity Indicator which is one of the simple method for humidity control. The Humidity Indicator shows the humidity conditions through color change. Therefore, photometer was used to correctly measure the color change of Humidity Indicator. As a result of lab test, Humidity Indicators was stabilized after one hour from en exposure in a certain humidity condition and the indicators indicated clear correlations between color changes of Humidity Indicators and humidity conditions. Some Humidity Indicators which had been selected through the lab tests were applied to preservation facilities of cultural heritages and the indicators indicated closed correlations with humidity conditions in indoor of facilities.

  • PDF

A Study on a Passive Sampler for Indoor Formaldehyde Using Methyl Yellow and Methyl Orange Indicator (Methyl yellow와 Methyl orange 지시약을 이용한 실내공기중의 포름알데히드 간이측정기에 대한 연구)

  • Jeong Sang Jin;Jang Jae Chul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.793-801
    • /
    • 2004
  • A passive sampler has been developed for measuring formaldehyde in air using methyl yellow and methyl orange indicator. It is based on the color change of the TLC plate on reaction with formaldehyde. TLC plates impregnated with three kinds of solutions containing methyl orange, methyl yellow, mixing of methyl yellow and methyl orange were shown rectilinear response to formaldehyde concentration at constant exposure time. The color change of impregnated TLC plate with criteria air pollution, such as NO$_2$, SO$_2$, CO, $O_3$ was investigated. The color change of TLC plate with $O_3$ is larger than other gases.

Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage (문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가)

  • Lim, Bo-A;Shin, Eun-Jeong;Lee, Sun-Myung
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

Edge-Adaptive Color Interpolation for CCD Image Sensor

  • Heo, Bong-Su;Hong, Hun-Seop;Gang, Mun-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • The color interpolation scheme can play an important role in overcoming the physical limitation of the CCD image sensor and in increasing the resolution of color signals, while most conventional approaches result in blurred edges and false color artifacts. In this paper, we have proposed an improved edge-adaptive color interpolation scheme for a progressive scan CCD image sensor with RGB color filter array The edge indicator function proposed utilizes not only the within-channel correlation but also the cross-channel correlation, and reflects the edge characteristics of an image adaptively. The color components unavailable for at each channel are interpolated along the edge direction, not across the edges, so that aliasing artifacts are supressed. Furthermore, we eliminated false color artifacts resulting from the color image formation model in the edge-adaptive color interpolation scheme by adopting the switching algorithm based on the color edge detection. Simulation results of the proposed algorithm indicate that the improved edge-adaptive color interpolation scheme produces quantitatively better and visually more pleasing results than conventional approaches.

Development of a Food Freshness Indicator for Monitoring Spoilage of Chicken Breast Using a Porous Substrate (다공성 기재를 이용한 닭가슴살 신선도 인디케이터 제조 및 특성)

  • Lee, Kaeun;Baek, Seunghye;Kim, Dowan;Seo, Jongchul
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.1
    • /
    • pp.37-45
    • /
    • 2017
  • To visually identify the spoilage of chicken breasts, a three layered freshness indicator consisting of PET/bromocresol green (BCG)-ethylene vinyl acetate (EVA)-acetic acid (AA) composite layer/porous substrates was successfully prepared and their performance were simulated at 20% of $CO_2$ and 4 different trimethylamine (TMA) concentrations to evaluate color change at minimal spoilage level. The visibility and range of color changes of the as-prepared indicators responding to TMA concentration as a simulant were strongly dependent on the concentrations of BCG and AA. As the BCG content increased, the visibility of color change in the freshness indicators was apparently improved and the range of color change could be controlled by contents of AA. Among the as-prepared freshness indicators, 'G0.12_A0.5' which consisting 0.12g of BCG and 0.5g of AA was selected as an optimum composition due to the highest visibility at TMA 20 mg% corresponding to the minimal spoilage level. The color of the indicator changed from yellow to green for spoilage indication of chicken breast, which could be easily seen with the naked eyes and well consistent with the simulation results. It is expected that our developed freshness indicator can be useful in monitoring various food freshness and quality.

A Time-temperature Indicator for A Vision Based-Detection System for Managing the Storage Temperature of Frozen Fish Products (냉동 수산물의 저장 온도 관리를 위한 Time-temperature Indicator와 비전 기반 Indicator 분석 프로그램 개발)

  • Jang, Myung-Kee;Hong, Chang-Wook;Choi, Jae-Hyuk;Kim, Koth-Bong-Woo-Ri;Choi, Jeong-Wook;Nam, Taek-Jeong;Ahn, Dong-Hyun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.1
    • /
    • pp.91-94
    • /
    • 2018
  • We develop a time-temperature indicator (TTI) that can determine whether thawing of fish and other fishery products has occurred during frozen storage. A polypropylene tube with an internal diameter of 3 mm was prepared and cut to a length of 14 to 20 mm. One end of the tube was thermally sealed and 0.1% acetic acid was injected into the other end; the tube was then frozen at $20^{\circ}C$. Then the open side of the frozen tube was blocked by sinking the tube into a 10% gelatin solution. The tube was attached to a polyvinyl packaging bag along blue litmus paper and the bag was put into a freezer at $-20^{\circ}C$. After freezing, the bag was removed to an ambient temperature of $20^{\circ}C$, and the time dependence of the color change of the litmus paper was observed. The color changed from blue to red, with the length of the red region increasing with time. Our TTI can be used as a part of a visible detection system and the detection program can conduct the elapsed time analysis on the length of the red region of the litmus paper indicating the degree of thawing. Thus, the TTI is a useful tool in the temperature management of frozen fish and fishery products.

Use of Freshness Indicator for Determination of Freshness and Quality Change of Tofu During Storage (신선도표시계를 이용한 두부의 저장 중 신선도 측정 및 품질 변화)

  • Shin, Hee-Young;Ku, Kyoung-Ju;Park, Sang-Kyu;Song, Kyung-Bin
    • Applied Biological Chemistry
    • /
    • v.49 no.2
    • /
    • pp.158-162
    • /
    • 2006
  • To determine freshness and quality change of tofu during storage, we manufactured a freshness indicator and monitored the surface pH, volatile basic nitrogen (VBN), thiobarbituric acid reacted substance (TBARS), total bacterial counts, and sensory evaluation. Tofu had a change in color of the freshness indicator after storage of 8 days at $4^{\circ}C$, and its pH and total bacterial counts reached 5.6 and 7.63 log CFU/g, respectively. VBN and TBARS values increased and reached the decay point at the time of color change of the freshness indicator. Sensory evaluation also indicated that samples were unacceptable by off-odor and decrease of firmness at day 8 of storage. These results suggest that a freshness indicator should be useful in determining expiration date of tofu products during marketing by indicating the microbial safety as well as sensory change.

Printable Time Temperature Integrator Consisting of Oxygen Indicator and Cover Film with Various Oxygen Permeability (다양한 산소 투과도를 가진 커버필름과 산소지시물질로 제작된 인쇄형 TTI)

  • Kim, Do Hyeon;Jang, Han Dong;Han, Seo Hyeon;Ahn, Myung Hyun;Lee, Seung Ju
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • A printable time temperature integrator (TTI) consisting of oxygen indicator and cover films with various oxygen permeability was developed. The printing ink contained methylene blue (oxygen indicator) which changed in color during storage. $TiO_2$ and glycerol for UV-activation of TTI and zein and ethanol for printing performance were also contained in the printing ink. The cover film on the ink was employed to control the color change rate and temperature dependency (Arrhenius activation energy, $E_a$) by using the different films (PE, PET, OPP, and LLDPE). The film properties were varied by annealing. TTI was produced by silk screen printing. As a result, the color change rates were different for the cover films, being the highest in TTI with LLDPE, followed by OPP, PE, and PET. The rate decreased with increase in the cover film thickness. The $E_a$ was the highest in TTI with LLDPE, followed by OPP, PE, and PET. The $E_a$ did not change with the cover film thickness. The annealed PVC and PET film were lower in oxygen permeability than the unannealed ones, indicating the lower color change rate.