• Title/Summary/Keyword: color ceramics

Search Result 93, Processing Time 0.024 seconds

Effects of coloring procedures on zirconia/veneer ceramics bond strength

  • Tuncel, Ilkin;Ozat, Pelin;Eroglu, Erdal
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.451-455
    • /
    • 2014
  • PURPOSE. The most common failure seen in restorations with a zirconia core is total or layered delamination of the ceramic veneer. In the present study, the shear bond strengths between veneering ceramics and colored zirconia oxide core materials were evaluated. MATERIALS AND METHODS. Zirconia discs ($15{\times}12{\times}1.6mm$) were divided into 11 groups of 12 discs each. Groups were colored according to the Vita Classic scale: A3, B1, C4, D2, and D4. Each group was treated with the recommended shading time for 3 s, or with prolonged shading for 60 s, except for the control group. Samples were veneered with 3 mm thick and 3.5 mm in diameter translucent ceramic and subjected to shear test in a universal testing machine with a crosshead speed of 1 mm/min. One-way analysis of variance (ANOVA) and Tukey's HSD tests were used for comparisons of the groups having the same shading times. A paired t-test was used for groups of the same color (3 s/60 s). RESULTS. Among the 11 groups investigated C4 (3 s) had the highest bond strength with a value of 36.40 MPa, while A3 (3 s) showed the lowest bond strength with a value of 29.47 MPa. CONCLUSION. Coloring procedures can affect zirconia/ceramic bond strength. However, the results also showed that bond strengths of all the investigated groups were clinically acceptable.

How will surface treatments affect the translucency of porcelain laminate veneers?

  • Turgut, Sedanur;Bagis, Bora;Ayaz, Elif Aydogan;Korkmaz, Fatih Mehmet;Ulusoy, Kivanc Utku;Bagis, Yildirim Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.8-13
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses. MATERIALS AND METHODS. A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with hydrofluoric acid; Group SB: sandblasted with 50-${\mu}m$ $Al_2O_3$; and Group L; irradiated with an Er;YAG laser. A translucent shade of resin cement (Rely X Veneer, 3M ESPE) was chosen for cementation. The color values of the veneers were measured with a colorimeter and translucency parameter (TP) values were calculated. A three-way ANOVA with interactions for TP values was performed and Bonferroni tests were used when appropriate (${\alpha}=0.05$). RESULTS. There were significant interactions between the surface treatments, ceramic shades and thicknesses (P=.001). For the 0.5-mm-thick specimens there were significant differences after the SB and L treatments. There was no significant difference between the HF and C treatments for any shades or thicknesses (P>.05). For the 1-mm-thick ceramics, there was only a significant difference between the L and C treatments for the HT shade ceramics (P=.01). There were also significant differences between the SB and C treatments except not for the HO shades (P=.768). CONCLUSION. The SB and L treatments caused laminate veneers to become more opaque; however, HF treatment did not affect the TP values. When the laminate veneers were thinner, both the shade of the ceramic and the SB and laser treatments had a greater effect on the TP values.

A Study on the Degradation Properties of DGEBA/TETA Epoxy System for Restoration of Ceramics by Temperature (도자기 복원용 DGEBA/TETA Epoxy계 수지의 온도에 의한 열화 특성 연구)

  • Nam, Byeong Jik;Jang, Sung Yoon
    • Journal of Conservation Science
    • /
    • v.31 no.4
    • /
    • pp.373-386
    • /
    • 2015
  • This study identified degradation properties by temperature stress with Araldite$^{(R)}$ AY103-1/HY956 used for ceramics. Tensile and compressive strength of durability increased for 6,480 hours at temperature of $34{\sim}45^{\circ}C$. In stability of external stress and temperature, compressive strength is superior to tensile strength, it requires conservation plans considering strength properties and stress of restoration materials. The tensile shear strength of adhesion properties decreased for 4,320 hours at temperature of $40{\sim}60^{\circ}C$. In ceramics with porosity, environments under isothermal-isohumidity are important because interfacial properties of adherend are concerned with performance variation. Glossiness decreased for 6,480 hours at temperature of $34{\sim}45^{\circ}C$ and color difference increased. Gloss stability was superior and color stability was weak, which requires improvement of optical properties. In artifacts on display in museums, there is concern about temperature rise on restoration materials by lighting therefore, it needs to minimize change in physical properties by exposure environments.

Comparative color and surface parameters of current esthetic restorative CAD/CAM materials

  • Egilmez, Ferhan;Ergun, Gulfem;Cekic-Nagas, Isil;Vallittu, Pekka Kalevi;Lassila, Lippo Veli Juhana
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.32-42
    • /
    • 2018
  • PURPOSE. The purpose of this study was to derive and compare the inherent color (hue angle, chroma), translucency ($TP_{SCI}$), surface gloss (${\Delta}E^*_{SCE-SCI}$), and surface roughness ($R_a$) amongst selected shades and brands of three hybrid CAD/CAM blocks [GC Cerasmart (CS); Lava Ultimate (LU); Vita Enamic (VE)]. MATERIALS AND METHODS. The specimens (N = 225) were prepared into square-shaped ($12{\times}12mm^2$) with different thicknesses and shades. The measurements of color, translucency, and surface gloss were performed by a reflection spectrophotometer. The surface roughness and surface topography were assessed by white light interferometry. RESULTS. Results revealed that hue and chroma values were influenced by the material type, material shade, and material thickness (P < .001). The order of hue angle amongst the materials was LU > CS > VE, whereas the order of chroma was VE > CS > LU. $TP_{SCI}$ results demonstrated a significant difference in terms of material types and material thicknesses ($P{\leq}.001$). $TP_{SCI}$ values of the tested materials were ordered as LU > CS > VE. ${\Delta}E^*_{SCE-SCI}$ and $R_a$ results were significantly varied amongst the materials (P < .001) and amongst the shades (P < .05). The order of ${\Delta}E^*_{SCE-SCI}$ amongst the materials were as follows $LU>VE{\geq}CS$, whereas the order of $R_a$ was $CS{\geq}VE>LU$. CONCLUSION. Nano-ceramic and polymer-infiltrated-feldspathic ceramic-network CAD/CAM materials exhibited different optical, inherent color and surface parameters.

COLOR COMPARISON OF VARIOUS POST SYSTEMS WITH EMPRESS 2 CROWNS (포스트의 종류에 따른 Empress 2 도재관의 색상에 관한 비교연구)

  • Lee Young-Soo;Yoo Dong-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.197-207
    • /
    • 2001
  • Development of new ceramics and esthetic needs of patients increase the use of all ceramic restorations. Fractured teeth often need metal post and core as foundation for final restoration. When all ceramic restorations are planned, metal post and core may lead to compromised esthetics because of opacity and gray color of metal post and core. Many techniques have been proposed to solve this problem such as application of an opaque porcelain to the metal core or all ceramic post and core. This study was performed to evaluate effect on color of Empress 2 crown according to various post systems. Color was evaluated by the CIE $L^*a^*b^*$ systems and measured by spectrophotometer (Model CM-3500, Minolta, Japan). Specimens were divided into 4 groups as follows Group 1 : gold cast post specimen + Empress 2 crown specimen Group 2 : application of an opaque porcelain to gold cast post specimen + Empress 2 crown specimen Group 3 : cosmopost specimen + Empress 2 crown specimen Group 4 : In-ceram post specimen + Empress 2 crown specimen. The results obtained as follows, 1. $L^*$ Values showed that group 2, 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 2. $a^*$ Values and $b^*$ values also showed that group 2. 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 3. ${\Delta}E^* ab$ Values showed that ${\Delta}E^* ab$ 3 was the highest value and ${\Delta}E^* ab$ 5 was the lowest value.

  • PDF

Development of Black Color Spinel Pigment for High Temperature (고온용 검정색 스피넬 안료의 개발)

  • Lee, Kwang-Ho;Myung, Min-Soo;Lee, Byung-Ha
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.5 s.300
    • /
    • pp.160-165
    • /
    • 2007
  • This research studied the most suitable synthesis condition of mineral pigments of black spinel, which have a stable chromogenic characteristic also ata high temperature of $1400^{\circ}C$ (it is not currently producedin the country) to meet not only functionality of ceramics but also an individual's aesthetic. It was synthesized by the plastic synthetic method on the basis of basic formation of $Fe_2O_3,\;Cr_2O_3$, Quartz, Kaolin, CoO, $MnO_2$, and plasticity was made at $1500^{\circ}C,\;1550^{\circ}C,\;1600^{\circ}C,\;1650^{\circ}C$. We researched the most suitable condition of plasticity and composition which make crystallization of spinel system and chromogenic characteristic close to black in every composition. And for the experiment of application to Zirconia, after adding synthesized pigments to Zirconia and plasticizing them, we analyzed their color and property of matters. The most suitable synthesis conditions of mineral pigments of black spinel system require composition of $Fe_2O_3-32.01%,\;Cr_2O_3-30.47%$, Quartz-9.66%, Kaolin-18.53%, CoO-3.71%, $MnO_2-5.62%$ and condition of plasticity kept for 1 h at $1600^{\circ}C$. When we added pigments synthesized in this way to Zirconia with 5 wt% and plasticized them at $1410^{\circ}C$, the result was that the degree of $strength-32.6kgf/mm^2$, absorptance-0.108%, $luminosity-L^*:37.54,\;color-a^*:1.31,\;b^*:2.61$ and their use suited for artificial jewelry or decoration Zirconia goods.

A Study on the Research Methods in History of Costume (복식사 연구방법에 관한 소고(I))

  • 신상옥
    • Journal of the Korean Home Economics Association
    • /
    • v.18 no.4
    • /
    • pp.41-45
    • /
    • 1980
  • We must identify the forms of dress devised throughout ages, when we wtudy, interpret and analyze the numerous resource material of costume. The study which depends on reference to actual artifacts is necessarily limited. Whereas items of contemporary dress are readily available, much from earlier eras has been destroyed or has deteriorated through time. Such as cottons, linens, silks, wools, leathers and furs are perishable organic materials. Few garments dated earlier than seventeenth century has survived except armor, jewelry. We have many sources of the information are available to study on costume of earlier eras. These sources are wall paintings, sculptures, painting, monumental brasses, manuscript illustration ceramics, coins, medals, mosaics, archives, literature. Wall painting and frescoes provided an useful source for costume study. Many wall paintings and frescoes were destroyed, were changed in color. It si advisable to interpret the dress detail, form color carefully. Sculpture would be useful to see the back and side views of dress. One of the most important points which should be made abut the use of sculpture as a source for costume study in early periods is that the sculptor's style will often change the character of a costume. As the painting si two-dimensional evidence for a three-dimensional costume, paintings must be accurately studied. What we must do, as far as we can, is to look at all visual representations in the light of other contemporary evidence in order to interpret the information correctly.

  • PDF

The effect of ceramic thickness and number of firings on the color of a zirconium oxide based all ceramic system fabricated using CAD/CAM technology

  • Bachhav, Vinay Chila;Aras, Meena Ajay
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.57-62
    • /
    • 2011
  • MATERIALS AND METHODS. Ceramics have a long history in fixed prosthodontics for achieving optimal esthetics and various materials have been used to improve ceramic core strength. However, there is a lack of information on how color is affected by fabrication procedure. The purpose of this study was to evaluate the effects of various dentin ceramic thicknesses and repeated firings on the color of zirconium oxide all-ceramic system (LavaTM) fabricated using CAD/CAM technology. MATERIALS AND METHODS. Thirty disc-shaped cores, 12 mm in diameter with a 1 mm thickness were fabricated from zirconium oxide based all ceramic systems ($Lava^{TM}$, 3M ESPE, St Paul, MN, USA) and divided into three groups (n = 10) according to veneering with dentin ceramic thicknesses: as 0.5, 1, or 1.5 mm. Repeated firings (3, 5, 7, or 9) were performed, and the color of the specimens was compared with the color after the initial firing. Color differences among ceramic specimens were measured using a spectrophotometer (VITA Easyshade, VITA Zahnfabrik, Bad $S{\ddot{a}}ckingen$, Germany) and data were expressed in CIELAB system coordinates. A repeated measures ANOVA and Bonferroni post hoc test were used to analyze the data (n = 10, ${\alpha}=.05$). RESULTS. $L^{\ast}a^{\ast}b^{\ast}$ values of the ceramic systems were affected by the number of firings (3, 5, 7, or 9 firings) (P<.001) and ceramic thickness (0.5, 1, or 1.5 mm) (P<.001). Significant interactions were present in $L^{\ast}a^{\ast}b^{\ast}$ values between the number of firings and ceramic thickness (P<.001). An increase in number of firings resulted in significant increase in $L^{\ast}$ values for both 0.5 mm and 1.5 mm thicknesses (P<.01, P=.013); however it decreased for 1 mm thickness (P<.01). The $a^{\ast}$ values increased for 1 mm and 1.5 mm thicknesses (P<.01), while it decreased for 0.5 mm specimens. The $b^{\ast}$ values increased significantly for all thicknesses (P<.01, P=.022). As the dentin ceramic thickness increased, significant reductions in $L^{\ast}$ values (P<.01) were recorded. There were significant increases in both $a^{\ast}$ and $b^{\ast}$ values (P<.01) as the dentin ceramic thickness increased. CONCLUSION. The number of firings and dentin ceramic thickness have a definite effect on the final color of all ceramic system tested. The mean ${\Delta}E$ value increased as the dentin ceramic thicknesses increased for zirconium-oxide based all ceramic specimens tested. However, the mean ${\Delta}E$ values were less than 3.7${\Delta}E$ units which is rated as a match in the oral environment.

COLOR STABILITY OF CEROMERS IN THREE FOOD COLORANTS (식용색소에 의한 CEROMER 수복물의 색안정성)

  • Jeong Yu-Jin;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.136-147
    • /
    • 2003
  • Statement of problem : Ceramic and composite resin have been used to fulfill the demand for esthetic prosthesis. However, ceramic is easy to break and wears off the opposite natural teeth. Conventional composite resin also has low abrasive resistance and color stability. Ceramic Optimized Polymer (ceromer) was developed in mid-1990s to overcome the shortfalls of ceramic and composite resin. Ceromer has similar abrasiveness with the natural tooth and has relatively high strength. Color stability affects esthetics and long-term prognosis of the prosthesis. Purpose The purpose of this study was to compare color stability of ceromers(2 types : $Artglass^{(R)}$. $Targis^{(R)}$) with ceramics ($Vintage^{(R)}$-polishing, $Vintage^{(R)}$-glazing). Material and Method : The color difference(${\Delta}E^*$) was measured by spectrophotometer with different immersion time. Twenty disks, 3mm in thickness and 10mm in diameter, were fabricated for each specimen in shade A2(Vita Lumin shade guide), Specimens (5 samples in each group) were immersed in the food colorants (Red no.3. Yellow no.4, Blue no.1, Distilled water) for 24 hours, 48 hours and 72 hours respectively. $L^*,\;a^*$ and $b^*$ value were measured with spectrophotometer (CM 503i : Minolta Co., Japan) and mean ${\Delta}E^*$ value was calculated for statistical analysis Results : The results of this study were obtained as follows. 1. The ${\Delta}E^*$ values of all test samples increased with the time of immersion. 2. The ${\Delta}E^*$ values of all materials increased in order of Distilled Water, Yellow no.4, Blue no.1 and fed no.3. There was significant difference between Red no.3 and the other food colorants(p<0.05). 3. The ${\Delta}E^*$ values increased in order of $Vintage^{(R)}$-glazing, $Vintage^{(R)}$-polishing. $Artglass^{(R)}$ and $Targis^{(R)}$. There was significant difference between $Vintage^{(R)}$-glazing and the other materials (p<0.05). Conclusion : By means of the above results, immersion time was found to be a critical factor for color stability of ceromer. For the long-term color stability of prosthesis it is recommended patients having ceromer prosthesis ($Artglass^{(R)},\;Targis^{(R)}$) to reduce the habitual intake of Red no.3 colorants con taming foods.

Synthesis of SnO2-TiO2-V2O5 System Yellow Pigment (SnO2-TiO2-V2O5계의 노랑안료 합성)

  • Joo, In-Don;Hwang, Dong-Ha;Lee, Hyun-Soo;Park, Joo-Seok;Lee, Byung-Ha
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.6
    • /
    • pp.639-642
    • /
    • 2009
  • The research was performed to find out the optimum firing condition for the $SnO_2-TiO_2-V_2O_5$ system yellow pigment. The pigment based on $SnO_2-V_2O_5$ system showed very intense yellow color and it was used widely in ceramics industry. Synthesized pigment, with partial substitutions of $SnO_2\;by\;TiO_2$, was fired at $1300{^{\circ}C}$ soaking 1h and it showed bright yellow color. $SnO_2-TiO_2-V_2O_5$ system was very more intensive changes in yellow color by colorimetric value $b^*$ than $SnO_2-V_2O_5$ system. Synthesized yellow pigments were characterized by X-ray diffraction (XRD), FT-IR, and UV-vis spectroscopy. The best composition for yellow pigment was 93:7:0.5(mole%) for $SnO_2-V_2O_5-TiO_2$. The measurement of CIE $L^*a^*b^*$ of pigment was $L^*(78.82),\;a^*(-4.88)\;and\;b^*$(59.25).