In 3D ultrasound color Doppler imaging (CDI), 8-16 pulse transmissions (ensembles) per each scanline are used for effective clutter rejection and flow estimation, but it yields a low volume acquisition rate. In this paper, we have evaluated three flow estimation methods: autoregression (AR), eigendecomposition (ED), and autocorrelation combined with adaptive clutter rejection (AC-ACR) for a small ensemble size (E=4). The performance of AR, ED and AC-ACR methods was compared using 2D and 3D in vivo data acquired under different clutter conditions (common carotid artery, kidney and liver). To evaluate the effectiveness of three methods, receiver operating characteristic (ROC) curves were generated. For 2D kidney in vivo data, the AC-ACR method outperforms the AR and ED methods in terms of the area under the ROC curve (AUC) (0.852 vs. 0.793 and 0.813, respectively). Similarly, the AC-ACR method shows higher AUC values for 2D liver in vivo data compared to the AR and ED methods (0.855 vs. 0.807 and 0.823, respectively). For the common carotid artery data, the AR provides higher AUC values, but it suffers from biased estimates. For 3D in vivo data acquired from a kidney transplant patient, the AC-ACR with E=4 provides an AUC value of 0.799. These in vivo experiment results indicate that the AC-ACR method can provide more robust flow estimates compared to the AR and ED methods with a small ensemble size.
Color Doppler imaging(CDI) was carried out to determine CDI-derived resistive index(RI) values of normal canine ophthalmic vasculature and its reproducibility. CDI was performed on 58 dogs. and normal ranges of RI value were calculated for the medial long posterior ciliary artery(mLPCA), ciliary artery(CA), and ophthalmic artery(OA). Ophthalmic vascular RI values of normal dogs were 0.67$\pm$0.07, 0.70$\pm$0.06, and 0.80$\pm$0.04 in mLPCA, CA, and OA, respectively. Means of RT value of all vessel had no statistically significant difference by sex, fellow orbits, and skull type. The results suggest that color Doppler imaging is a noninvasive test which has the advantage of providing objective measurements of blood flow velocity parameter in the canine eye and orbit.
Color Doppler imaging (CDI) was carried out to evaluate the anesthetics effect on ophthalmic circulation using CDI-derived resistive index (RI) values. CDI was preformed on 24 dogs, and RI values were calculated for the medial long posterior ciliary artery (mLPCA) and ophthalmic artery (OA) before and after administration of anesthetics. After administration of benoxinate or acepromazine, a significant change of the mLPCA RI was not found. But, a significant decrease of the RI following ketamine (p < 0.001) or xylazine (p < 0.01) administration could be observed as compared with the self-control. Mean RI value of OA also showed this same trend. Intraocular pressure was significantly decrease following benoxinate (p < 0.01), acepromazine (p < 0.01), and xylazine (p < 0.001) administration within normal range. The results suggest that some anesthetics influence on ophthalmic vascular resistance. Therefore, chemical restraint was carefully used in clinical application of CDI-derived RI measurement. Particularly, benoxinate and acepromazine is useful chemical restraint without a change of the ophthalmic vascular resistance.
Journal of the Korean Society for Industrial and Applied Mathematics
/
v.20
no.3
/
pp.175-202
/
2016
Ultrasound imaging is a widely used tool for visualizing human body's internal organs and quantifying clinical parameters. Due to its advantages such as safety, non-invasiveness, portability, low cost and real-time 2D/3D imaging, diagnostic ultrasound industry has steadily grown. Since the technology advancements such as digital beam-forming, Doppler ultrasound, real-time 3D imaging and automated diagnosis techniques, there are still a lot of demands for image quality improvement, faster and accurate imaging, 3D color Doppler imaging and advanced functional imaging modes. In order to satisfy those demands, mathematics should be used properly and effectively in ultrasound imaging. Mathematics has been used commonly as mathematical modelling, numerical solutions and visualization, combined with science and engineering. In this article, we describe a brief history of ultrasound imaging, its basic principle, its applications in obstetrics/gynecology, cardiology and radiology, domestic-industrial products, contributions of mathematics and challenging issues in ultrasound imaging.
Journal of the Korea Academia-Industrial cooperation Society
/
v.8
no.5
/
pp.1047-1056
/
2007
Basically, an ultrasonic imaging system has two fundamental imaging modes available. One is the B-mode imaging modality which provides an image of reflection coefficient, and the other is the Doppler color flow mode that maps blood flow inside the human heart and blood vessels. This paper presents a new method of detecting and compensating for aliasing that occurs when the Doppler frequency exceeds one-half of the pulse-repetition frequency (PRF). Its validity is shown by computer simulation. The new method not only extends the measurable Doppler frequency, but also helps to reduce the effect of noise. The results show that the aliasing can be compensated for correctly fur signal-to-noise ratios down to 20 dB.
Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.
Seo, Jun-Yeong;Kim, Tae Jung;Kim, Sang Rim;Nam, Kwang Woo
The Journal of Korean Orthopaedic Ultrasound Society
/
v.6
no.1
/
pp.10-14
/
2013
Pilomatricoma is a benign skin tumor that develops from hair matrix cells. It most commonly occurs in the head and neck, followed by the upper extremities. Accuracy of preoperative diagnosis was low in previous studies and excisional biopsy was even performed frequently without imaging studies. We report a case of pilomatricoma of the shoulder that was easily diagnosed by ultrasound including color Doppler, which is a more useful imaging modality than computed tomography or magnetic resonance imaging scans not only because of its cost effectiveness but also because of the precise information obtained from mass contents.
The complications of deep neck infection have become much less common in the antibiotic era. The vascular complications of deep neck infection can have devasting consequences. Most commonly, the internal carotid artery is involved, although the common carotid and external carotid artery can also be affected.0 the cases of patients with a protracted course, recurrent bleeding, cranial neuropathies, or trismus, the presence of vascular complications must be considered. Appropriate imaging should be carried out to allow the localization of the infection and ascertain the status of the vessels in the neck The vascular structures can be imaged with duplex doppler or color doppler flow ultrasound to see the flow between the mass and vessels. Also angiography plays a key role in the diagnosis and management of vascular complication of deep neck infection. Prompt diagnosis and treatment of these patients is necessary to prevent significant hemmorrhagic complications. We experienced a case of pseudoaneurysm of the common carotid artery secondary to deep neck infection treated successfully with surgical excision in 45-year-old-male.
Journal of the Korea Academia-Industrial cooperation Society
/
v.12
no.5
/
pp.2261-2266
/
2011
Being the most widely used in ultrasound Doppler color flow mapping, the Kasai algorithm, also known as lag-1 autocorrelation method, is capable of estimating the Doppler mean frequency relatively accurately with a modest amount of computation. Particularly in the case of imaging deep lying areas, however, its performance suffers due to low signal-to-noise ratios. The purpose of this paper is to propose a dealiased lag-2 autocorrelation method which is superior to the Kasai algorithm even at low signal-to-noise ratios and to compare their performances through simulations. The proposed algorithm is found to be better by about 2 to 3 dB than the Kasai algorithm in terms of Doppler mean frequency estimation error in the presence of measurement noise.
Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.