Evaluation of Resistive Index Using Color Doppler Imaging in Canine Ophthalmic Vasculature

개의 안혈관에 대한 컬러도플러초음파를 사용한 저항지수의 평가

  • Lee, Hee-Chun (College of Veterinary Medicine, Seoul National University) ;
  • Yoon, Jung-Hee (College of Veterinary Medicine, Seoul National University)
  • Published : 2003.06.01

Abstract

Color Doppler imaging(CDI) was carried out to determine CDI-derived resistive index(RI) values of normal canine ophthalmic vasculature and its reproducibility. CDI was performed on 58 dogs. and normal ranges of RI value were calculated for the medial long posterior ciliary artery(mLPCA), ciliary artery(CA), and ophthalmic artery(OA). Ophthalmic vascular RI values of normal dogs were 0.67$\pm$0.07, 0.70$\pm$0.06, and 0.80$\pm$0.04 in mLPCA, CA, and OA, respectively. Means of RT value of all vessel had no statistically significant difference by sex, fellow orbits, and skull type. The results suggest that color Doppler imaging is a noninvasive test which has the advantage of providing objective measurements of blood flow velocity parameter in the canine eye and orbit.

개의 정상안혈관저항지수와 그 재현성을 측정하고자 컬러도플러 초음파를 이용하여 본 실험을 수행하였다. 내측 긴 후모양체 동맥, 모양체 동맥, 안동맥의 혈관저항지수의 정상범주를 측정하기 위하여 58두의 개에서 컬러도플러 초음파를 실시하였다. 정상견에서 내측 긴 후모양체동맥, 모양체동맥, 안동맥의 저항지수(%)를 측정한 결과, 그 수치는 각각 0.67$\pm$0.07, 0.70$\pm$0.06, 그리고 0.08$\pm$0.04이었으며, 모든 혈관의 저항지수는 좌우안구간에 차이가 없었으며, 성별이나 두개골 형태가 미치는 영향도 없는 것으로 판명되었다. 안혈관 저항지수의 반복측정에 따른 오차를 평가하기 위해서 4회 반복 측정한 결과, 안동맥저항지수의 반복측정변이계수가 4.1%로 가장 낮았으며 긴 후모양체동맥과 모양체동맥의 저항지수의 반복측정변이계수는 각각 12.9%와 7.8%로 모든 동맥에서 높은 재현성을 보였다. 이상의 결과로 보아, 컬러도플러 초음파가 개의 안구 및 안와의 혈순환에 대한 객관적인 측정자료를 제시하는데 매우 유용한 지표인 것으로 판단된다.

Keywords

References

  1. Ultrasound Med. Biol. v.16 Sitedependent effects of increases in placental vascular resistance on the umbilical arterial velocity waveform in fetal sheep Adamson,S.L.;Morrow,R.J.;Langille,B.L. https://doi.org/10.1016/0301-5629(90)90082-N
  2. J. Ultrasound Med. v.14 Color Doppler imaging of the eye. Normal ranges, reproducibility, and observer variation Baxter,G.M.;Williamson,T.H.
  3. Curr. Eye Res. v.16 Effect of one week of levobunolol HCl 0.5% on the human retinal circulation Bloom,A.H.;Grunwald,J.E.;Dupont,J.C. https://doi.org/10.1076/ceyr.16.3.191.15415
  4. Eye v.2 Doppler ultrasound studies of the ophthalmic artery Canning,C.R.;Restori,M. https://doi.org/10.1038/eye.1988.19
  5. J. Ultrasound Med. v.14 Variability in measurement of central retinal artery velociy using color doppler imaging Dennis,K.J.;Dixon,E.D.;Winsberg,F.;Ernest,J.T.;Goldstick,T.K.
  6. Vet. Ophthalmol. v.2 Comparative Doppler imaging of the ophthalmic vasculature in normal beagles and beagles with inherited primary open angle glaucoma Gelatt,K.J.;Gelatt,K.N.;Mackay,E.;Brooks,D.E.;Newell,S.M. https://doi.org/10.1046/j.1463-5224.1999.00064.x
  7. Vet. Ophthalmol. v.2 Doppler imaging of the ophthalmic vasculature of the normal dog, Blood velocity measurements and reproducibility Gelatt,K.J.;Gelatt,K.N.;Mackay,E.;Brooks,D.E.;Newell,S.M.
  8. J. Ultrasound Med. v.12 Color Doppler assessment of normal ocular blood flow Giovagnorio,F.;Quaranta,L.;Bucci,M.G.
  9. Acta Ophthalmologica v.65 Regional ocular blood flow after chronic topical glaucoma drug treatment Green,K.;Hatchett,T.L. https://doi.org/10.1111/j.1755-3768.1987.tb07030.x
  10. Ophthalmology v.102 Color doppler imaging of normal orbital vasculature Greenfield,D.S.;Heggerick,P.A.;Hedges,T.R.
  11. Acta Ophthalmologica v.58 Pulsed doppler ultrasound for measuring blood flow velocity in the human ophthalmic circulation Kvernes,S.;Blika,S.;Giltvedt,J.;Matre,K.;Kristoffersen,K.;Grip,A.;Brubakk,A.O. https://doi.org/10.1111/j.1755-3768.1980.tb08330.x
  12. Arch. Ophthalmol. v.109 Color doppler imaging of the eye and orbit : Technique and normal vascular anatomy Lieb,W.E.;Cohen,S.M.;Merton,D.A.;Shields,J.A.;Mitchell,D.G.;Goldberg,B.B. https://doi.org/10.1001/archopht.1991.01080040095036
  13. Pediatr. Res. v.24 Ophthalmic artery blood flow velocity in healthy term and preterm neonates Lindner,W.;Schaumberger,M.;Versmold,H.T. https://doi.org/10.1203/00006450-198811000-00015
  14. Ophthalmology v.101 Dipivefrin reduces blood flow in the ciliary body in humans Michelson,G.;Groh,M.J.M.
  15. Ophthalmology v.104 Color doppler imaging of ophthalmic artery blood flow velocity : A study of repeatability and agreement Quaranta,L.;Harris,A.;Donato,F.;Cassamali,M.;Semeraro,F.;Nascimbeni,G.;Gandolfo,E.;Quaranta,C.A. https://doi.org/10.1016/S0161-6420(97)30256-5
  16. Eye v.7 The effect of acetazolamide on the retinal circulation Rassam,S.M.B.;Patel,V.;Kohner,E.M. https://doi.org/10.1038/eye.1993.159
  17. Invest. Ophthalmol. Vis. Sci. v.35 Blood flow after retinal ischemia in cats Roth,S.;Pietrzyk,Z.
  18. Fundamentals of Veterinary Ophthalmology v.7-9 Structure and function of the eye. Slatter,D.;Slatter,D.(ed.)
  19. Retina v.16 Doppler ultrasonography of the central retinal artery by duplex scanning Steigerwalt,R.D.;Cesarone,M.R.;Laurora,G.;Belcaro,G.V.;Sanctis,M.T.;Incandela,L.;Christopoulos,V.
  20. Br. J. Ophthalmol. v.78 no.12 Ocular blood flow measurement Williamson,T.H.;Harris,A. https://doi.org/10.1136/bjo.78.12.939
  21. Eye v.7 Colour doppler velocimetry of the arterial vasculature of the optic nerve head and orbit Williamson,T.H.;Baxter,G.M.;Dutton,G.N. https://doi.org/10.1038/eye.1993.16
  22. Exp. Eye Res. v.46 Choroidal blood flow measured in the dog eye in vivo and in vitro by local hydrogen clearance polarography : Validation of a technique and response to raised intraocular pressure Yu,D.;Alder,V.A.;Cringle,S.J.;Brown,M.J. https://doi.org/10.1016/S0014-4835(88)80021-6