• 제목/요약/키워드: coil number

검색결과 286건 처리시간 0.027초

코일에 흐르는 전류밀도를 변화시킨 자장압축전기의 출력특성 (Output Characteristics of Helical Magnetic Flux Compression Generators with Varing Current Density Flowing through Coil)

  • 국정현;안재운;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.21-23
    • /
    • 2002
  • We designed and manufactured helical magnetic flux compression generator, in which, the current density was reduced by increasing the number of wires by stages, and the voltage between wires was reduced by decreasing the time rate of inductance change. The figure of merit and the energy multiplication ratio of the generator were measured as a function of current density flowing through coil and their characteristics were analyzed. When the current density of coil was more than 250 kA/cm, the figure of merit and the energy multiplication ratio were decreased rapidly.

  • PDF

Spontaneous Splenic Rupture in a Vivax Malaria Case Treated with Transcatheter Coil Embolization of the Splenic Artery

  • Kim, Na Hee;Lee, Kyung Hee;Jeon, Yong Sun;Cho, Soon Gu;Kim, Jun Ho
    • Parasites, Hosts and Diseases
    • /
    • 제53권2호
    • /
    • pp.215-218
    • /
    • 2015
  • An enlarged spleen is considered one of the most common signs of malaria, and splenic rupture rarely occurs as an important life-threatening complication. Splenectomy has been recommended as the treatment of choice for hemodynamically unstable patients. However, a very limited number of splenic rupture patients have been treated with transcatheter coil embolization. Here we report a 38-year-old Korean vivax malaria patient with ruptured spleen who was treated successfully by embolization of the splenic artery. The present study showed that angiographic embolization of the splenic artery may be an appropriate option to avoid perioperative harmful effects of splenectomy in malaria patients.

Multifunctional Robotic Guidewire System using Spiral-type Magnetic Microrobot with Magnetic Manipulation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.616-621
    • /
    • 2016
  • This paper presents a new multifunctional active guidewire system for medical applications that uses a magnetic microrobot. The study demonstrated that the proposed microrobot system could swim and be controlled under Low-Reynolds-number (Re) environments in blood vessel models. The prototype of the robotic guidewire, which is driven within a three-axis Helmholtz coil system, consists of a guide-wire, spiral blade, drilling tip, and permanent magnet. The spiral-type microrobot showed stable active locomotion between 3 kA/m and 9.1 kA/m under driving frequency up to 70 Hz in a silicone oil (of viscosity 1000 cst). The microrobot produced a maximum moving velocity of $8.08{\times}10^{-3}m/s$ at 70 Hz and 9.1 kA/m. In particular, the robotic guidewire produced 3D locomotion with drilling in the three-axis Helmholtz coil system. We verified active locomotion, towing of guidewire, steering, and drilling of the proposed robotic guidewire system through experimental analyses.

전자클러치의 동특성 해석 (Analysis of Dynamic Characteristics of an Electro-Magnetic Clutch)

  • 김연호;김현수
    • 한국자동차공학회논문집
    • /
    • 제1권1호
    • /
    • pp.101-109
    • /
    • 1993
  • Dynamic characteristics of an electro-magnetic clutch transmission system were investigated by using Bondgraph modeling method. Simulation results showed that when the rotor engaged with the armature, the response time of the current, the driver torque, the rotational speed and the relative sliding time between the driver and the driven side decreased, as the gap size between the rotor and the armature decreased and the number of coil turns increased. Also, when the rotor disengaged with the armature, the delay time increased with the decreased gap size and the increased number of coil turns. It was found that the experimental results of the current, the driver torque, the rotational speeds were in good accordance with the theoretical results. The results of this study can be used as basic design materials of the electro-magnetic clutch.

  • PDF

무전극 형광램프용 페라이트에 따른 전기적 및 광학적 특성 (Electrical and Optical Characteristics by Ferrite for Electrodeless Fluorescent Lamp)

  • 백광현;양종경;이종찬;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.200-206
    • /
    • 2006
  • An electric power efficiency of electrodeless fluorescent lamp depens on a big relative property of gas, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. in lamp. We used magnetic substance that opens self-examination material of electrodeless fluorescent lamp antenna. We used Mn-Zn type as the Ferrite. We have examined resistance, impedance and Q-factor's frequency characteristic by ferrite. Coil turns were changed from 13 to 15 turns to recognize brightness change of lamp by winding number. Optical equipment (LS-100) was used to measure brightness. We could know Q-factor's difference according to material is important part of antenna design. When an electrodeless fluorescent lamp was made using T company's PE22, it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

E-H Mode Transition Properties of Cylindrical ICP Hg:Kr

  • Yang Jong-Kyung;Pack Kwang-Hyun;Lee Jong-Chan;Park Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권3호
    • /
    • pp.124-130
    • /
    • 2005
  • In this paper, we designed a cylindrical type light source having an electromagnetic principle of inductively coupled plasma, and measured its electrical-optical properties. Using the transformer principle, an electrically equivalent circuit cylindrical type light source was analyzed. According to the parameters of electromagnetic induction, which were diameter of coil with cpO.3$\~$ 1.2mm, number of turns with 4$\~$ 12 turns, distance with 40$\~$ l20mm and RF power with 10$\~$ 150W, the electrical .md optical properties were measured. When the diameter of the coil was cp0.3mm, number of turns was 8 and distance was 40mm, and the maximum brightness of 29,730 cd/m$^{2}$ was shown with RF power l50W. The relationship between electromagnetic induction and plasma discharges was demonstrated using the mode transition from E-mode to H-mode

BLDC 모터 고정자 슬롯 형상설계에 관한 연구 (A Study On The Stator Slot Shape Design of BLDC Motor)

  • 한상록;이강연;정병호
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.41-49
    • /
    • 2015
  • In this paper, we studied an optimal design and efficiency improvement of the BLCD motor used in home electronic appliance. The number of stator slots is chosen depending on the rotor poles, phase number, and the winding configuration. In general, a fractional slots/pole design is preferred to minimize cogging torque. To reduce the winding resistance, we reduced the coil length and we improved the coil space factor. We proposed three types of stator slot shape design for the optimal BLDC motor design. One of them, U-type slot shape is a best optimal design, it proved by the simulated and tested. Optimal design of essential parameters aiming at high winding factor are presented to create for a high-quality system implementation. Design analysis is verified by testing and building a prototype motor.

자왜방식 원거리 초음파검사를 위한 단층 송수신 나선형 코일 배열 (Single Layer Array of Transmitting and Receiving Spiral Coils for Magnetostrictive Type Long-Range Ultrasonic Testing)

  • 최명선;김유진;이효문
    • 비파괴검사학회지
    • /
    • 제33권2호
    • /
    • pp.219-225
    • /
    • 2013
  • 자왜방식 원거리 초음파검사의 최적화된 개별 응용들을 위해, 분리되어 적층된 송수신 나선형 코일 배열들이 사용되어 왔었다. 본 연구에서는 기존에 비해 반으로 줄어든 다리 폭을 갖는 나선형 코일들과 이 다리 폭 감소에 기인한 빈 공간들을 활용할 때, 보다 쉬운 사용과 제조를 허용하는 단층 구조를 형성하도록 송수신 코일들이 배열될 수 있다는 것을 실증하였다. 다리 폭에 비례하는 수신코일의 감은 수 때문에 단층 코일 배열의 감도는 대응되는 이층 코일 배열의 그것의 반 정도이었지만 이는 메인-뱅(main bang) 에코로 인한 포화로부터 수신증폭기의 보다 빠른 회복을 허용하였다. 또한 지향성 조종과 SNR(signal-to-noise ratio)의 관점에서는 이 두 종류의 코일 배열들이 거의 같은 성능을 갖는 것으로 밝혀졌다.

기일고류동층내류동화(氣一固流動層內流動化) 및 전열특성(傳熱特性)에 관한 연구(硏究)(II) (Fluidization and Heat Transfer Characteristics in the Fluidized Bed(II))

  • 박종순;백고길;김은영;전성탁
    • 태양에너지
    • /
    • 제14권2호
    • /
    • pp.51-60
    • /
    • 1994
  • 본 연구에서는 Furan foundry sand 유동층에서 유동화 특성과 Single spiral coil tube에 대한 열전달 특성을 실험하였으며, 전열관의 Pitch와 직경의 비(p/Do=1.58, 2.37, 3.17, 4.75) 및 전열관의 Pitch와 유동입자 크기의 비(p/dp=21.25, 25.15, 30.18, 35.93)가 전열특성에 미치는 영향을 실험적으로 연구하였다. 그 결과 다음과 같은 결론을 얻었다. 1) p/Do가 증가 할수록 평균 열전달계수는 증가한다. 2) 평균 Nusselt수의 증가율은 p/Do=4.75일 때보다 1.58 일 때가 더 크다. 3) 평균 Nusselt수와 Re수, $Pr_g$수 및 p/dp의 상관 관계식은 다음과 같이 나타낼 수 있었다. $Nu_{mean}=C\;Re^m\;Pr_g^{0.4}(p/dp)^n$.

  • PDF

3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과 (Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.