• 제목/요약/키워드: coil loss

검색결과 206건 처리시간 0.027초

H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

전자장 해석 프로그램을 이용한 와전류 문제의 해석 및 이해 (Analysis and Understanding of Eddy Current Problem using electromagnetic field Packeg)

  • 임건규;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1237-1238
    • /
    • 2006
  • When the coil with alternating current approaches to the conductor the eddy current flows in conductor. Eddy current is concentrated on the conductor surface and decrescent because of skin effet.. In this paper investigated eddy current characteristic that is happened in conductor. Analyzed characteristic using electromagnetic field finite element analysis program that is commercialized to analyze value of eddy current and penetration depth. Analyzed creation value of eddy current and penetration depth in conductor that change operation frequency and the material of conductor, coil outside diameter, inside diameter, position, type of conductor from analyzed eddy current characteristic. The results. using distribution of eddy current and penetration depth data is that will help to forecast ECT(Eddy Current Testing), Eddy current application and use field, eddy current loss.

  • PDF

Performance Analysis of Magnetic Power Pads for Inductive Power Transfer Systems with Ferrite Structure Variation

  • Kim, Minkook;Byun, Jongeun;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1211-1218
    • /
    • 2017
  • In this paper, performance of rectangular shaped magnetic power pads for inductive power transfer (IPT) system according to ferrite structure is analyzed. In order to evaluate the influences of ferrite structure, six cases of magnetic power pads are proposed. Self-inductance, coupling coefficient, quality factor, and coil to coil efficiency are compared as the displacement increases in the direction of x or y axis. For accurate estimation, finite element method (FEM) simulation is used and loss components of the power pads are numerically calculated and considered. Through the simulation and measured results, effectiveness of protrusive and enveloping ferrite structure is identified.

전자장 해석 프로그램을 이용한 와전류 문제의 해석 및 이해 (Analysis and Understanding of Eddy Current Problem using electromagnetic field Packeg)

  • 임건규;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1697-1698
    • /
    • 2006
  • When the coil with alternating current approaches to the conductor the eddy current flows in conductor. Eddy current is concentrated on the conductor surface and decrescent because of skin effect. In this paper investigated eddy current characteristic that is happened in conductor. Analyzed characteristic using electromagnetic field finite element analysis program that is commercialized to analyze value of eddy current and penetration depth. Analyzed creation value of eddy current and penetration depth in conductor that change operation frequency and the material of conductor, coil outside diameter, inside diameter, position, type of conductor from analyzed eddy current characteristic. The results, using distribution of eddy current and penetration depth data is that will help to forecast ECT(Eddy Current Testing), Eddy current application and use field, eddy current loss.

  • PDF

인버터 서지에 의한 견인전동기 고정자 권선의 전기적 특성 변화 (Properties of Electrical Performance by Inverter Surge on Stator Coil of Traction Motor)

  • 박현준;장동욱;최남호;최종선;김종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1285-1287
    • /
    • 2003
  • The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking. the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss($tan{\delta}$), capacitance and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor.

  • PDF

와전류 손실을 적용한 금형으로 제조된 초고압 변압기의 프레스보드의 절연 특성 연구 (A Study on the Insulating Properties of Pressboard for High Voltage Transformer Applied the Mold of Eddy Current Loss)

  • 서왕벽
    • 한국전기전자재료학회논문지
    • /
    • 제28권8호
    • /
    • pp.508-512
    • /
    • 2015
  • Some insulating materials are tested and analyzed with variables to obtain the reliable pressboard which is located to core and coil of high voltage transformer. The high voltage transformer is used in electrical power system and operating reliability. Optimization possibility of pressboard shape including electrical insulation performance could be achieved by analysis simulation. Using insulating pressboard, which is made by mold applied eddy current loss, it could be measured the influences of moisture content for electrical properties. As a result, it is to contribute to improve the performance and ensure the reliability of the pressboard by investigating electrical strength according to the variation oil temperature. In addition pressboard thickness is important design factor to ensure electrical strength in high voltage transformer.

고온초전도 적층선재의 손실과 적층선재로 제작한 팬케이크 권선의 손실 (AC Losses of the Multi-stacked HTS tapes and Pancake Coil)

  • 이승욱;김용섭;이희준;차귀수;이지광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.776-778
    • /
    • 2004
  • In this paper, we present effect of the stacked HTS tapes. AC losses of HTS pancake windings with stacked tapes are shown. Magnetic flux density in the HTS winding under operating conditions was calculated by FEM. AC loss of the pancake winding were measured and compared with the calculated loss by using AC losses of the stacked samples. Test results show that measured results generally agreed well with the calculated value by using AC loss of 4-stacked sample data.

  • PDF

상악견치 후방견인시 저항원 조절을 위한 MAS(Molar Anchoring Spring)의 초기 응력분포에 관한 광탄성학적 연구 (A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF THE MOLAR ANCHORING SPRING(MAS) DURING RETRACTION OF THE MAXILLARY CANINE)

  • 전윤식
    • 대한치과교정학회지
    • /
    • 제26권4호
    • /
    • pp.341-348
    • /
    • 1996
  • 저자는 마찰견인법으로 상악견치 후방견인시 저항원상실을 최소화하기 위해 근심 경사된 구치를 직립시키는 Molar Uprighting Spring의 작용기전을 응용하고 마찰견인법의 장점을 이용하여 임상적으로 사용이 용이하며 저항원상실이나 견치의 조절되지 못한 경사이동(uncontrolled tipping)등의 부작용을 최소화 할 수 있는 장치인 Molar Anchoring Spring(MAS)을 고안하였다. MAS를 임상에 적용한 결과 비교적 만족스러운 결과를 얻어 이에 장치를 소개하며 MAS의 저항원 조절능력과 견치의 이동양상을 평가하기 위하여 광탄성 모형을 제작한 후 주호선에 diameter 0.009" lumen size 0.030" NiTi closed coil spring만을 장착하여 250gm의 견인력이 발생하도록 한 경우와, 같은 NiTi closed coil spring으로 동일한 견인력 이 발생하도록 하고 .017" X .025" TMA wire로 $60^{\circ}$의 tip-back bend를 부여하여 수직교정력이 60-70gm이 되도록 제작한 MAS를 제1대구치 auxiliary tube에 삽입하고 견치 전방에 걸어준 경우를 비교실험 하여 견치견인시 초기응력분포를 관찰한 결과 다음과 같은 결과를 얻었다. 1. 주호선(main arch wire)에 저항원 조절을 위한 조치없이 견치에 수평견인력만을 가했을 때 구치부에 심한 저항원상실은 물론 견치의 원심이동양상도 조절되지 못한 경사이동(uncontrolled tipping)으로 나타났다. 2. 구치부의 저항원 조절을 위해 사용한 MAS는 견치의 원심이동 초기에 구치부 저항원 조절효과와 견치의 정출없는 조절된 경사이동(controlled tipping)을 유도할 수 있는 장치로 나타났다.

  • PDF

Development of Ground-Based Search-Coil Magnetometer for Near-Earth Space Research

  • Shin, Jehyuck;Kim, Khan-Hyuk;Jin, Ho;Kim, Hyomin;Kwon, Jong-Woo;Lee, Seungah;Lee, Jung-Kyu;Lee, Seongwhan;Jee, Geonhwa;Lessard, Marc R.
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.509-515
    • /
    • 2016
  • We report on development of a ground-based bi-axial Search-Coil Magnetometer (SCM) designed to measure time-varying magnetic fields associated with magnetosphere-ionosphere coupling processes. The instrument provides two-axis magnetic field wave vector data in the Ultra Low Frequency or ULF (1 mHz to 5 Hz) range. ULF waves are well known to play an important role in energy transport and loss in geospace. The SCM will primarily be used to observe generation and propagation of the subclass of ULF waves. The analog signals produced by the search-coil magnetic sensors are amplified and filtered over a specified frequency range via electronics. Data acquisition system digitizes data at 10 samples/s rate with 16-bit resolution. Test results show that the resolution of the magnetometer reaches $0.1pT/{\sqrt{Hz}}$ at 1 Hz, and demonstrate its satisfactory performance, detecting geomagnetic pulsations. This instrument is scheduled to be installed at the Korean Antarctic station, Jang Bogo, in the austral summer 2016-2017.