• Title/Summary/Keyword: coil constant

Search Result 163, Processing Time 0.022 seconds

The Design Method of the Torquer in DTG (자이로스코프에서 토커의 설계 및 해석)

  • 김홍규;정현교;홍선기
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.1
    • /
    • pp.48-53
    • /
    • 1996
  • The role of the torquer in dynamically tuned gyroscope (DTG) is to erect the slanted rotor straight. This IBper presents the design method of the torquer. The torquer must satisfy the desired maximum angular velocity condition. The performance of magnet-residual flux density, maximum energy product, and so on-is limited by the material characteristics. So we should design the torquer with the limited condition that magnet performance is given. If the mechanical size of DTG is deter-mined, the dimension of the torquer is calculated and the space of the torquer becomes constant. Therefore, if we determine the diameter of the torquer coil, the number of coil turns is calculated automatically. Using these dimensions, we can calculate the torque and the scale factor. The maximum angular velocity is computed if we know the maximum current density. The analysis of the torquer was carried out by the 3-dimensional finite element method. The proposed algorithm of the torquer design was valid in comparison with the experimental data obtained from fabricated DTG.

  • PDF

A Study on the Stifness of Coil Spring in the Three Dimensional Space (3차원 공간에서 코일스프링의 강성에 관한 연구)

  • 이수종
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1130-1139
    • /
    • 2001
  • Springs are widely utilized in machine element. To find out stiffness of coil spring, the space beam theory using the finite element method is adopted in this paper. In three dimensional space, a space frame element is a straight bar of uniform cross section which is capable of resisting axial forces, bending moments about two principal axes in the plane of its cross section and twisting moment about its centroidal axis. The corresponding displacement degrees of freedom are twelve. The displacements of nodal points due to small increment of force are calculated by the finite element method and the calculated nodal displacements are added to coordinates of nodal points. The new stiffness matrix of the system using the new coordinates of nodal points is adopted to calculated the another increments of nodal displacements, that is, the step by step method is used in this paper. The results of the finite element method are fairly well agreed with those of various experiments. Using MATLAB program developed in this paper, spring constants can be predicted by input of few factors.

  • PDF

A Study on the Contour Design in the Hinge Mechanism for a Folder of a Mobile Phone (휴대폰 폴더용 힌지기구의 윤곽 설계에 관한 연구)

  • Park, Jong-Keun;Lee, Soo-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.86-94
    • /
    • 2008
  • A total stroke of an opening or closing motion of a hinge mechanism in a folder-type mobile phone is composed of two portions. In the first portion, human fingers act a force to open or close the folder. In this portion, the rotating folder compresses the coil spring installed in the mechanism. In the last portion, this compressed coil spring generates a torque to rotate the folder. The main merit of this study is that we have designed a hinge mechanism to be operated by a uniform torque in the first portion of the total stroke. The uniform torque means that it is constant along the folder's swing angle. This mechanism will give softer feeling to human fingers. A pair of contours in the mechanism plays an important role. It transforms rotation into translation in the first portion; on the other hand, it transforms translation into rotation in the last portion. In this study, we have developed an algorithm to obtain the pair of contour curves. We divided the total contour curves into finite sub-intervals. Assuming that the curves in every sub-interval are parabolas, we have obtained the coefficients of them by solving systems of nonlinear equations recursively.

DEVELOPMENT OF IMMERSION TYPE MOLTER STREEL LEVELMETER

  • Morii, Michio;Azuma, Makoto;Kobayashi, Kazuo;Tezuka, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1316-1321
    • /
    • 1990
  • Molten steel level information of ladle is very important for process control in steelmaking process. At secondary refining process, measuring lance and snokel have to keep constant thier depth from molten steel surfaces. But, there is much slag on the molten steel surface. Besides, not only the thickness of slag is varied with refining condition, but also molten steel level is largely affected by firebrick errosion. Then, optical measuring method and/or by human eyes cannot detect true molten steel surface, but slag surface. This slag thickness is 300mm at maximum, then huge diameter eddy current sensor will be needed if that type sensor is applied. In addition to, cooling system is necessary because the molten steel and slag temperature is high. This is not practically. To solve this problem, immersion type levelmeter is developed. This sensor is made up from primary and secondary cylindrical coils. High frequency current is applied to primary coil. Electro-motive force from secondary coil is measured, which is varied with molten steel level. This complete set is installed within stainless steel long capsule and attached to top of lance. This sensor is immersed into molten steel bath of ladle or tundish with protection of expendable paper sleeve.

  • PDF

A Reproducible High Etch Rate ICP Process for Etching of Via-Hole Grounds in 200μm Thick GaAs MMICs

  • Rawal, D.S.;Agarwal, Vanita R.;Sharma, H.S.;Sehgal, B.K.;Muralidharan, R.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • An inductively coupled plasma etching process to replace an existing slower rate reactive ion etching process for $60{\mu}m$ diameter via-holes using Cl2/BCl3 gases has been investigated. Process pressure and platen power were varied at a constant ICP coil power to reproduce the RIE etched $200{\mu}m$ deep via profile, at high etch rate. Desired etch profile was obtained at 40 m Torr pressure, 950 W coil power, 90W platen power with an etch rate ${\sim}4{\mu}m$/min and via etch yield >90% over a 3-inch wafer, using $24{\mu}m$ thick photoresist mask. The etch uniformity and reproducibility obtained for the process were better than 4%. The metallized via-hole dc resistance measured was ${\sim}0.5{\Omega}$ and via inductance value measured was $\sim$83 pH.

Design and Characteristic Analysis of Linear Oscillating Actuator with Structure (직선 왕복 액추에이터의 구조에 따른 설계 및 특성 검토)

  • Kim, Hae-Joong;Lee, Choong-Sung;Hong, Jung-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.537-544
    • /
    • 2015
  • This paper provided two types of design method on moving core type LOA and one type of design method on moving coil type LOA, and compared and examined each of its characteristics. In order to conduct parametric design process, voltage equation was used to schematize Lmin/K and L/M map, and the schematized map was used to determine Lmin, K or L, M. In order to meet requirements such as thrust force and input voltage and to satisfy the target values of Lmin, K or L, M, the types and sizes of each type were designed using geometry design process. 2-FEA was conducted for each of the designed model. After examining thrust force based on the location of the mover, Type-1 showed radical change in thrust force as movers moved, and Type-2 and Type-3 showed constant appearance of thrust force. The total volume of the designed LOA model was compared to select the model with highest thrust force density. Also, the weight of the mover for each model was compared in order to select the model that was predicted to have highest mechanical responsiveness and stroke characteristics.

Full Wave Cockroft Walton Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.246-252
    • /
    • 2011
  • A high-voltage power supply has been built for activation of the brain via stimulation using a Full Wave Cockroft-Walton Circuit (FWCW). A resonant half-bridge inverter was applied (with half plus/half minus DC voltage) through a bidirectional power transistor to a magnetic stimulation device with the capability of producing a variety of pulse forms. The energy obtained from the previous stage runs the transformer and FW-CW, and the current pulse coming from the pulse-forming circuit is transmitted to a stimulation coil device. In addition, the residual energy in each circuit will again generate stimulation pulses through the transformer. In particular, the bidirectional device modifies the control mode of the stimulation coil to which the current that exceeds the rated current is applied, consequently controlling the output voltage as a constant current mode. Since a serial resonant half-bridge has less switching loss and is able to reduce parasitic capacitance, a device, which can simultaneously change the charging voltage of the energy-storage condenser and the pulse repetition rate, could be implemented. Image processing of the brain activity was implemented using a graphical user interface (GUI) through a data mining technique (data mining) after measuring the vital signs separated from the frequencies of EEG and ECG spectra obtained from the pulse stimulation using a 90S8535 chip (AMTEL Corporation).

An Experimental Study on a Solenoid Eddy Current Sensor to inspect Deteriorations in Overhead Distribution Lines (가공 배전선의 열화를 검출하기 위한 솔레노이드 와전류 센서의 실험적 연구)

  • 김성덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 1999
  • This paper deals with an experirrental study of a nondestructive testing system using a solenoid eddy currnet sensor to inspect deteriorations in overhead distribution lines, such as broken wires, severe local corrosion or zinc loss. Corrosion rrechanisrn for ACSR and ACSR-OC is discussed and characteristics for a solenoid sensor to insprt the georretrical pararreters of the coil and testing materials impOOance are briefly analyzed. A measurement system having a constant current source, a signal processing unit and a motor driver is impIemented. This instrument has such capabilities as detecting the sensor output and estimating dinHlsions of the testing conductors, continuously. As a result, it was shown that the eddy current sensor with an encircling coil could effectively estimate the diatreter change due to deteriorations in overhead distribution lines. lines.

  • PDF

Electrical and thermal properties of polyamideimide-colloid silica nanohybrid for magnetic enameled wire

  • Han, S.W.;Kang, D.P.
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.428-432
    • /
    • 2012
  • Polyamidimide (PAI)-colloidal silica (CS) nanohybrid films were synthesized by an advanced sol-gel process. The synthesized PAI-CS hybrid films have a uniform and stable chemical bonding and there is no interfacial defects observed by TEM. The thermal degradation ratio of PAI-CS (10 wt%) hybrid films is delayed by 100 ℃ compared with pure PAI sample determined by on set temperature range in TGA. The dielectric constant of PAI-CS (10 wt%) hybrid films decreases with increasing CS content up to about 5 wt% but increases at higher CS content, which is not explained simply by effective medium therories (EMT). The duration time of PAI-CS (10 wt%) hybrid coil is 38 sec, which is very longer than that of pure PAI coil sample. The PAI-CS (10 wt%) hybrid film has a higher breakdown voltage resistance than the pure PAI film at surge environment and exhibits superior heat resistance. The PAI-CS (10 wt%) sample shows the advanced and stable thermal emission properties in transformer module compared with the pure PAI sample. This result illustrates that the advanced thermal conductivity and expansion properties of PAI-CS sample in the case of appropriate sol-gel processes brings the stable thermal emission in transformer system. Therefore, new PAI-CS hybrid samples with such stable thermal emission properties are expected to be used as a high functional coating application in ET, IT and electric power products.

DC V-I Characteristics of a High Temperature Superconductor for a 600 kJ Superconducting Magnetic Energy Storage Device in an Oblique External Magnetic Field (경사 외부자장에 대한 600 kJ급 SMES용 HTS도체의 DC V-I 특성)

  • Li, Zhu-Yong;Ma, Yong-Hu;Ryu, Kyung-Woo;Choi, Se-Yong;Kim, Hae-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • We are developing a small-sized high temperature superconducting magnetic energy storage (HTS-SMES) magnet with the nominal storage capacity of 600 kJ, which provides electric power with high quality to sensitive electric loads. Critical current and N-value of a high temperature superconductor with large current, which was selected for the development of the 600 kJ HTS-SMES magnet, were investigated in various oblique external magnetic fields. Based on the critical current and N-value measured for the short sample conductor, we discussed the DC V - I characteristic of a model coil fabricated with the same conductor of 500 m. The results show that the measured critical current and N-value of the conductor for parallel field are constant in external magnetic fields less than about 0.2 T. However, for oblique fields, its critical current and N -value abruptly decrease in all external magnetic fields. Moreover, the measured critical current of the model coil well agrees with the numerically calculated one based on the DC V - I characteristic measured for the short sample conductor. This suggest that losses and critical currents for an HTS-SMES magnet made up of a high temperature superconductor with anisotropic characteristic are predictable from the data of a short sample conductor.