• Title/Summary/Keyword: code switch

Search Result 50, Processing Time 0.02 seconds

Analysis of Diagnosis Algorithm Implemented in TCU for High-Speed Tracked Vehicles (고속 무한궤도 차량용 변속제어기 진단 알고리즘 분석)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.30-38
    • /
    • 2018
  • Electronic control units (ECUs) are currently popular, and have evolved further towards the high-end application of autonomous vehicles in the automotive industry. Such digital technologies have also become widespread, in agriculture and construction equipment. Likewise, transmission control of high-speed tracked vehicles is based on the transmission control unit (TCU), performing complex gear change control functions, and diagnostic algorithms (a TCU's self-diagnostic and reporting capability of malfunction data through CAN communication). Since all functions of TCU are implemented by embedded-software, it is hardly possible to analyze specifications by reverse engineering. In this paper a real-time transmission simulator adaptable to TCU is presented, for analysis of diagnosis algorithm and standards. Signal simulation circuits are deliberately designed considering electrical characteristics of TCU inputs and various analysis tools, such as analog input auto scan function, and global output enable switch, are implemented in software. Test results from hardware-in-the-loop simulator verify tolerance time for each error, as well as cause of fault, error reset conditions.

An Analysis of Optimal Sequences for the Detection of Wake-up Signal in Disaster-preventing Broadcast (재난방송용 대기모드 해제신호 검출을 위한 최적 부호 성능 분석)

  • Park, Hae Yong;Jo, Bonggyun;Kim, Heung Mook;Han, Dong Seog
    • Journal of Broadcast Engineering
    • /
    • v.19 no.4
    • /
    • pp.491-501
    • /
    • 2014
  • Recently, the need for disaster-preventing broadcast has increased gradually to cope with natural disaster like earthquake and tsunami causing enormous losses of both life and property. In disaster-preventing broadcast system, the wake-up signal is used to alert user terminal and switch the current state of channel to the emergency channel, which is for the fast and efficient delivery of emergency information. In this paper, we propose the detection method of wake-up signal for disaster-preventing broadcast systems. The wake-up signals for disaster-preventing broadcast should have a good auto-correlation property in low power and narrow-band conditions that does not affect the existing digital television (DTV) system. The suitability of the m-sequence and complementary code (CC) is analyzed for wake-up signals according to signal to noise ratio. A wake-up signal is proposed by combining the direct sequence spread spectrum (DSSS) technique and pseudo noise (PN) sequences such as Barker and Walsh-Hadamard codes. By using the proposed method, a higher detecting performance can be achieved by the spreading gain compared to the single long m-sequence and the Golay code.

A Study for Hybrid Honeypot Systems (하이브리드 허니팟 시스템에 대한 연구)

  • Lee, Moon-Goo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.127-133
    • /
    • 2014
  • In order to protect information asset from various malicious code, Honeypot system is implemented. Honeypot system is designed to elicit attacks so that internal system is not attacked or it is designed to collect malicious code information. However, existing honeypot system is designed for the purpose of collecting information, so it is designed to induce inflows of attackers positively by establishing disguised server or disguised client server and by providing disguised contents. In case of establishing disguised server, it should reinstall hardware in a cycle of one year because of frequent disk input and output. In case of establishing disguised client server, it has operating problem such as procuring professional labor force because it has a limit to automize the analysis of acquired information. To solve and supplement operating problem and previous problem of honeypot's hardware, this thesis suggested hybrid honeypot. Suggested hybrid honeypot has honeywall, analyzed server and combined console and it processes by categorizing attacking types into two types. It is designed that disguise (inducement) and false response (emulation) are connected to common switch area to operate high level interaction server, which is type 1 and low level interaction server, which is type 2. This hybrid honeypot operates low level honeypot and high level honeypot. Analysis server converts hacking types into hash value and separates it into correlation analysis algorithm and sends it to honeywall. Integrated monitoring console implements continuous monitoring, so it is expected that not only analyzing information about recent hacking method and attacking tool but also it provides effects of anticipative security response.

A Study on the Ignition Distance from a Leakage Point of the LP Gas Pipe (LP 가스 배관의 누출부로부터 점화가능 거리에 관한 연구)

  • Ryou, Young-Don;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.70-76
    • /
    • 2017
  • The standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" prescribe the separation distance between gas piping joint excluding welded joints and electric equipments(electric switch, watt meter, breaker, connector, etc). The "Korea Electro technical Regulation" also prescribes the distance between gas piping joints and electric equipments in accordance with the gas related standards. In case of the standards related to the "Urban Gas Business Act", the distance criteria stipulated in the standard of supplying facilities are different from those stipulated in the standard of using facilities. In this study, we have conducted pilot test on the possible ignition distance from the piping joint when LP gas is leaked from the point. We have also examined the adequacy of current standards on the separation distance between gas piping joint and electric equipments. As a result of the tests, we have found that ignition is able to occur at a distance of 30 cm as stipulated in the current standards or more when LP gas is leaked from the joint of the pipe. Therefore, we have made a decision that the criteria for separation distance between gas piping joint and electric equipment specified in the current standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" is appropriate.

Numerical Simulation of Flow past Forced and Freely Vibrating Cylinder at Low Reynolds Number

  • Jung, Jae Hwan;Nam, Bo Woo;Jung, Dong-Ho
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.3 no.4
    • /
    • pp.165-173
    • /
    • 2017
  • This study aims at validating simulations of the forced and freely vibrating cylinders at Reynolds number of approximately 500 in order to identify the capability of the CFD code, and to establish the analysis process of the vortex-induced vibration (VIV). The direct numerical and large eddy simulations were employed to resolve the various length scales of the vortices, and the morphing technique was used to consider a motion of the circular cylinder. For the forced vibration case, both in- and anti-phase VIV processes were observed regarding the frequency ratio. Namely, when the frequency ratio approaches to unity, the synchronization/lock-in process occurs, leading to substantial increases in drag and lift coefficients. This is strongly linked with the switch in timing of the vortex formation, and this physical tendency is consistent with that of Blackburn and Henderson (J. Fluid Mech., 1999, 385, 255-286) as well as force coefficients. For the free oscillation case, the mass and damping ratio of 50.8 and 0.0024 were considered based on the study of Blackburn et al. (J. Fluid Struct., 2000, 15, 481-488) to allow the direct comparison of simulation results. The simulation results for a peak amplitude of the cylinder and a shedding mode are reasonably comparable to that of Blackburn et al. (2000). Consequently, based on aforementioned results, it can be concluded that numerical methods were successfully validated and the calculation procedure was well established for VIV analysis with reasonable results.

An Automated Code Generation for Both Improving Performance and Detecting Error in Self-Adaptive Modules (자가 적응 모듈의 성능 개선과 오류 탐지를 위한 코드 자동 생성 기법)

  • Lee, Joon-Hoon;Park, Jeong-Min;Lee, Eun-Seok
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.9
    • /
    • pp.538-546
    • /
    • 2008
  • It has limits that system administrator deals with many problems occurred in systems because computing environments are increasingly complex. It is issued that systems have an ability to recognize system's situations and adapt them by itself in order to resolve these limits. But it requires much experiences and knowledge to build the Self-Adaptive System. The difficulty that builds the Self-Adaptive System has been problems. This paper proposes a technique that generates automatically the codes of the Self-Adaptive System in order to make the system to be built more easily. This Self-Adaptive System resolves partially the problems about ineffectiveness of the exceeded usage of the system resource that was previous research's problem and incorrect operation that is occurred by external factors such as virus. In this paper, we applied the proposed approach to the file transfer module that is in the video conferencing system in order to evaluate it. We compared the length of the codes, the number of Classes that are created by the developers, and development time. We have confirmed this approach to have the effectiveness.

High-Throughput QC-LDPC Decoder Architecture for Multi-Gigabit WPAN Systems (멀티-기가비트 WPAN 시스템을 위한 고속 QC-LDPC 복호기 구조)

  • Lee, Hanho;Ajaz, Sabooh
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.104-113
    • /
    • 2013
  • A high-throughput Quasi-Cyclic Low-Density Parity-Check (QC-LDPC) decoder architecture is proposed for 60GHz multi-gigabit wireless personal area network (WPAN) applications. Two novel techniques which can apply to our selected QC-LDPC code are proposed, including a four block-parallel layered decoding technique and fixed wire network. Two-stage pipelining and four block-parallel layered decoding techniques are used to improve the clock speed and decoding throughput. Also, the fixed wire network is proposed to simplify the switch network. A 672-bit, rate-1/2 QC-LDPC decoder architecture has been designed and implemented using 90-nm CMOS standard cell technology. Synthesis results show that the proposed QC-LDPC decoder requires a 794K gate and can operate at 290 MHz to achieve a data throughput of 3.9 Gbps with a maximum of 12 iterations, which meet the requirement of 60 GHz WPAN applications.

An Efficient Network System Call Interface supporting minimum memory copy (메모리 복사를 최소화화는 효율적인 네트워크 시스템 호출 인터패이스)

  • 송창용;김은기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4B
    • /
    • pp.397-402
    • /
    • 2004
  • In this paper, we have designed and simulated a new file transmission method. This method restricts memory copy and context switching happened in traditional file transmission. This method shows an improved performance than traditional method in network environment. When the UNIX/LINUX system that uses the existing file transfer technique transmits a packet to the remote system, a memory copy between the user and kernel space occurs over twice at least. Memory copy between the user and kernel space increase a file transmission time and the number of context switching. As a result, the existing file transfer technique has a problem of deteriorating the performance of file transmission. We propose a new algorithm for solving these problems. It doesn't perform memory copy between the user and kernel space. Hence, the number of memory copy and context switching is limited to the minimum. We have modified the network related source code of LINUX kernel 2.6.0 to analyzing the performance of proposed algorithm and implement new network system calls.

A Study on the Rake Finger System Design for the System Performance Improvement in the Mobile Communications (시스템 효율향상을 위한 이동통신망 Rake Finger 시스템 설계에 관한 연구)

  • Lee Seon-Keun;Lim Soon-Ja
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1A
    • /
    • pp.31-36
    • /
    • 2004
  • In this paper, we proposed the new structure of the Rake Finger using Walsh Switch, the shared accumulator, and the pipeline-FWHT algorithm for reducing the signal processing complexity resulting from the increase of the number of data correlator. The function simulation of the proposed architecture is performed by Synopsys tool and the timing simulation is performed by Compass tool. The number of computational operation in the proposed data correlators is 160 additions and the conventional ones is 512 additions when the number of walsh code N=4. As a result, it is reduced about 3.2 times other than the number of computational operation of the conventional ones. Also, the result shows that the data processing time of the proposed Rake Finger architecture is 90,496[ns] and the conventional ones is 110,696[ns]. It is $18.3\%$ faster than the data processing time of the conventional Rake Finger architecture.

Study on Post-Fire Safe Shutdown Analysis using an Imaginary Plant for Training (교육용 가상원전을 이용한 화재안전정지분석에 관한 연구)

  • Lee, Jaiho;Kim, Jin Hong
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.57-65
    • /
    • 2018
  • In this study, a post-fire safe shutdown analysis (PFSSA) including multiple spurious operation (MSO) treatments for cables was conducted with an imaginary nuclear power plant for training using a deterministic fire analysis code. The imaginary nuclear power plant for the training consisted of a reactor containment building and an auxiliary building, including a total of 22 fire areas. The equipment including valves, pumps, emergency diesel generators, switch gears, motor control centers, and logic controllers were located in each fire area of the imaginary plant. It was assumed that each equipment is connected with two cables and that each cable passes through the fire areas along the cable trays. A database containing the information on the equipment and cables for the imaginary plant was constructed for the fire area analysis. The fire area analysis was performed for several assumed MSO scenarios, equipment logics, and cable logics. A mitigation measure using a three hour rated wrap was applied to the failed cables and cable trays after the fire area analysis.