• Title/Summary/Keyword: co-housing

Search Result 384, Processing Time 0.03 seconds

Preparation and Characterization of Wood Polymer Composite by a Twin Screw Extrusion (이축 압출공정을 이용한 Wood Polymer Composite의 제조 및 특성 분석)

  • Lee, Jong-Hyeok;Lee, Byung-Gab;Park, Ki-Hun;Bang, Dae-Suk;Jhee, Kwang-Hwan;Sin, Min-Cheol
    • Elastomers and Composites
    • /
    • v.46 no.3
    • /
    • pp.211-217
    • /
    • 2011
  • Wood Polymer Composite (WPC) has attracted a great deal of attention in environmental industries due to renewable resources, processability, excellent physical properties and logging regulations for application to housing units and engineering construction materials. In this study, commercial WPCs were prepared by using a modular intermeshing co-rotating twin screw extruder. The effect of three main factors such as wood flour contents, coupling agent concentrations and pre-treatment of wood flour on the properties of WPCs was extensively investigated. It was found that tensile strength and thermal stability were decreased with increasing wood flour contents whereas the water absorption was increased. Addition of maleic anhydride grafted polypropylene (PP-g-MA) into WPC exhibited better physical properties. On the contrary, the water absorption was slightly decreased with PP-g-MA. Finally the sample, which was prepared with pre-treated wood flour, represented the highest tensile strength. However, the water absorption of the sample was increased due to the transition of crystalline structure of cellulose.

The Real Scale Fire Test for Fire Safety in Apartment Housing (실물화재실험을 통한 공동주택의 화재안전성 연구)

  • Yoo, Yong-Ho;Kweon, Oh-Sang;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.57-65
    • /
    • 2009
  • This study was intended to conduct a Real-scale fire test to predict the fire behavior by unit space at the apartment building where a huge casualties and injuries are likely. After setting the inflammables inside the house, the test aimed to identify the fire characteristics to each unit item was carried out. The house was divided into 4 unit space such as kitchen, living room, bedroom and a study for a real scale fire test. As a result, bedroom reached to flashover state in 5minutes after setting the fire, indicating a rapid fire growth such as 7433.3kW of maximum thermal emissivity, 578.6ppm of carbon monoxide, 1.25ppm of carbon dioxide and $1,350^{\circ}C$ of maximum indoor temperature. Particularly, the fire growth was made up to critical temperature which might cause a severe damage to the people within 3minutes, if the fire were not extinguished at inflammable space at the early stage of fire, which stressed the need of early response. The result of a real scale fire test could be compared with the outcome of expanded simulation test and used in predicting the fire spread at the space for different use.

A Study on Development of Evaluation Indicator for Golf Course User's Preference (골프장 이용자 선호도 평가지표 개발)

  • Seok, Young-Han;Moon, Seok-Ki;Lee, Eun-Yeob
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.4
    • /
    • pp.25-34
    • /
    • 2010
  • This study was conducted to develop evaluation indicators to improve athletic performance and operational management of golf courses and the results of the research are as follows. Through theoretical research and a preliminary professional survey, 15 on-going evaluations of golf course composition and operational management and 55 sub-evaluation indices were rejected while 10 on-going evaluations and 52 sub-evaluation indicators were reconfigured as final for environmental-friendliness, level of member services, level of human service of game personnel, difficulties of course, management level of the course, fairness of operational management, accessibility and location characteristic, traditions and ambiance of the golf club, quality of course, and course layout. When analyzing the important decision factors in golf course user preference evaluation indicators, the following contributed in the order of higher to lower contributions: the management level of the course, excellence of the course, level of human services for personnel, course layout and environmental-friendliness. When identifying the path coefficient of golf course evaluation indicators, the curvature of a hole and the length of the course had a causal effect on the 'course layout' section. Tournament facilities and various shot values had a causal relationship with 'excellence of the course', in the order of higher to lower, and convenience of waiting and fair allocation of reservations for 'fairness of operational management'. The history of the golf course and its environmental characteristics, history and culture of the region have relatively higher causal effects on 'traditions of the golf club' and geographical conditions on 'accessibility and location characteristics', pesticide and fertilizer usage and water pollution on 'environmental-friendliness', and member benefit and kindness of employees on 'level of member services'. The kindness and expertise of the game personnel had a relatively higher causal effect on the 'level of human services of game personnel', the location of tenning area, and location of OB and hazards on 'difficulties of course', and rough conditions and obstacles management on 'management level of the course'. There is a need to complete a systematic evaluation index system for golf course user preferences through future studies for a more detailed assessment, as well as a process to verify these evaluation indicators by application to domestic and international golf courses.

Effect of Various Forms of Floor System on Performance of Meat-type Duck and Environments of Duck House (오리사 바닥 형태가 육용오리의 생산성 및 사육환경에 미치는 영향)

  • Bang, Han-Tae;Kim, Dong-Woon;Hwangbo, Jong;Na, Jae-Cheon;Kang, Hwan-Ku;Kim, Min-Ji;Mushtaq, M.M.H.;Parvin, R.;Choi, Hee-Chul;Lee, Sang-Bae;Kang, Min;Kim, Ji-Hyuk
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • This experiment was conducted to investigate the effects of floor type and heating system on performance, housing environment and health status of ducks reared in three types of duck house (OD : Open floor house-Direct heating system, OF : Open floor house-Floor heating system and LD : Loft type house-Direct heating system). In OF treatment, PVC pipes were installed for heating under concrete floor and covered with litter. In LD treatment, plastic mesh was installed 50 cm above the floor so that duck's droppings can pass through it. Each treatment had four replicates of 25 birds (Cherry Valley duck breed) per pen. There were no significant differences in weight gain and feed intake of ducks for 6 weeks among all treatments. However, feed conversion ratio in LD was significantly higher (p<0.05) than that in OF. No differences were found in carcass charac- teristics, with the exception of abdominal fat weight where OF were higher than the others. Concentrations of $CO_2$ and $NH_3$ gas in OD were higher than those of OF and LD at 3, 4 and 5 weeks. Moisture content in litter of OF was lower than that of OD. In contrast, the amount of dust in the air was higher in OF than in OD. The amount of fuel used for 6 weeks in LD was lower about 21% than that in OD. Some of unusual symptoms were observed in open floor house and loft type house, such as lying, spraddle legged, twisted ankle and legs, wounded sole, or etc. No components of leukocyte and erythrocyte of blood were significantly different among all treatments. The results of this experiment showed that OF and LD systems had no positive effects on performance of meat type commercial duck. However, there were some positive effects of certain house type for the improvement of environmental condition in duck house for hygienic production. In the future, more research on the effect of various facilities and systems for duck house is needed.

A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room (X선촬영실 내에서의 공간산란선량 변동에 관한 연구)

  • Oh, Hyun-Joo;Kim, Sung-Soo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

Groundwater-use Estimation Method Based on Field Monitoring Data in South Korea (실측 자료에 기반한 우리나라 지하수의 용도별 이용량 추정 방법)

  • Kim, Ji-Wook;Jun, Hyung-Pil;Lee, Chan-Jin;Kim, Nam-Ju;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.467-476
    • /
    • 2013
  • With increasing interest in environmental issues and the quality of surface water becoming inadequate for water supply, the Korean government has launched a groundwater development policy to satisfy the demand for clean water. To drive this policy effectively, it is essential to guarantee the accuracy of sustainable groundwater yield and groundwater use amount. In this study, groundwater use was monitored over several years at various locations in Korea (32 cities/counties in 5 provinces) to obtain accurate groundwater use data. Statistical analysis of the results was performed as a method for estimating rational groundwater use. For the case of groundwater use for living purposes, we classified the cities/counties into three regional types (urban, rural, and urban-rural complex) and divided the groundwater facilities into five types (domestic use, apartment housing, small-scale water supply, schools, and businesses) according to use. For the case of agricultural use, we defined three regional types based on rainfall intensity (average rainfall, below-average rainfall, and above-average rainfall) and the facilities into six types (rice farming, dry-field farming, floriculture, livestock-cows, livestock-pigs, and livestock-chickens). Finally, we developed groundwater-use estimation equations for each region and use type, using cluster analysis and regression model analysis of the monitoring data. The results will enhance the reliability of national groundwater statistics.

Surface Checking Reduction Effect of Preservative-treated Korean Larch Round-woods with Various Physical Treatments (물리적 처리에 따른 낙엽송 방부원주목의 표면할렬 방지효과)

  • Pang, Sung-Jun;Oh, Jung-Kwon;Lee, Sang-Joon;Park, Jun-Ho;Jang, Sung-Il;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.107-115
    • /
    • 2017
  • In this study, the surface check reduction effect of preservative-treated Korean larch round-wood was investigated by applying three physical treatments, such as incising, kerfing, and kiln-drying. Moreover, the possibility of long-term service life was also checked by comparing the depth of surface check and the penetration depth of preservative. A rapid gradient of wood moisture content between surface and center causes a surface check. Thus, the effect of reducing surface check was carried out at the lowest equilibrium moisture content (EMC) condition, temperature ($2^{\circ}C$), humidity (44.6%), in outdoor locations in Korea until the test specimens reach to the 8.6% EMC. As a result, the preservative-treated specimens without incising, kerfing, kiln-drying (Type C) could not ensure the long-term service life due to a large surface check. Because the surface check depth of all specimens was deeper than the penetration depth of preservative. In case of the incising treated specimens (Type I), 80% of them, the depth of surface check was not deeper than the penetration depth of preservative. However, when a kerfing was additionally treated (Type B), a possibility of happening deeper surface check than penetration depth of preservative was increased rather than Type I.

Landscape Design Proposal for Gangbuk Large Park (강북 대형공원 기본계획)

  • Kim, Do-Kyong;Choi, Won-Man;Hong, Hyoung-Soon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.4
    • /
    • pp.1-14
    • /
    • 2008
  • Although the Dreamland site was the only flat amusement park in the northern part of Seoul, the site lost its function as a regional park due to aging and, therefore, was no longer in use. The site is surrounded by currently existing high dense low-story housing blocks and proposed new towns. A renovation plan for Dreamland was raised by the City of Seoul to enhance the quality of the urban environment in the northern part of Seoul. This study articulates the design concepts and strategies of the prizewinning work of the International Design Competition for Gangbuk Large Park. The three key points can be summarized as follows: First, this design proposal tried to find a new possibility for a large mountain park in an urban areas. These days, mountain parks are used limitedly as ordinary living spaces for activities such as a walking, hiking, and physical training. New strategies were sought to reconstruct the sentiment with which our ancestors enjoyed the mountains. Second, this proposal tried to make Dreamland a socially self-sufficient park. We designed a park which generates self-energy and which communicates with the city, not a park which only exists as a green island in a city. Lastly, rain fed paddy fields, a typical Korean vernacular landscape, was a tangible space which represented people's life-styles harmonizing with the nature. Rain fed paddy fields is a design motif which puts the three surrounding mountains together with the site. It is expected that the new design will works as a noted place.

Development of Tacho Generator for Application of Anti-aircraft Weapon System (대공무기체계 적용을 위한 타코제너레이터 개발)

  • Byun, Kisik;Park, Jun Young;Cho, Sung-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.174-180
    • /
    • 2020
  • This paper presents the development of a tacho generator that is applicable to a DC motor for anti-aircraft weapon systems. In general, devices such as tacho generators and resolvers are used as feedback devices for controlling DC motors. A tacho generator with a wide operating temperature range was developed, which has robust characteristics against shock loads and vibrations according to the operational characteristics of anti-aircraft weapon systems. The target specifications were set based on the requirements of the tacho generator currently in operation. A rotor coupled to the shaft of the motor and a stator coupled to the housing of the motor were then designed and manufactured. The inductance was 31.0 mH, the terminal resistance was 147.7 ohms, and the rotational measurement factor was satisfactory under both normal operation and operating conditions after the maximum speed for the standard of 9.500 ± 0.475 V/krpm. In addition, the environmental suitability of the applied equipment was confirmed through the rate of change in unit temperature, and it was found that the temperature characteristics were all within 0.03 %/℃.

The Relationship between the Growth of Central City and the Growth of Suburban Areas in U.S. Metropolitan Cities (미국 대도시지역들의 도심지역과 교외지역 성장간의 관계에 관한 연구)

  • Lee, Jong-Ho;Lee, Eun-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.9 no.1
    • /
    • pp.86-96
    • /
    • 2003
  • The purpose of this paper is to explore the relationship between central city and suburban areas. In particular, we examine the relationship of construction activities in suburban areas with construction activities in central city. That is because if the construction activities in central city are correlated with those in suburban areas, the economic trends in those two parts would become interdependent. The construction permit data in 114 Metropolitan Statistical Areas (MSAs) for the past 11 years are used as a central explanatory variable of influencing the relationship, as construction permits issued would reflect population growth, economic growth and housing price in certain area. The main findings of our analysis are as follows. First, MSAs classified as showing high population growth has higher correlation between central city and suburban area than MSAs showing low population growth rate except for only office construction. However, there is little difference in correlation characteristic by the size of MSA Second, most of the MSAs show little causality between the central city and suburban area in lagged situation. Therefore, it is hard to say that the past trend of construction activity in central city reflects in direct the future trend of construction activities in suburban area.

  • PDF