• 제목/요약/키워드: closely-spaced

검색결과 136건 처리시간 0.02초

Feedback control design for intelligent structures with closely-spaced eigenvalues

  • Cao, Zongjie;Lei, Zhongxiang
    • Structural Engineering and Mechanics
    • /
    • 제52권5호
    • /
    • pp.903-918
    • /
    • 2014
  • Large space structures may have resonant low eigenvalues and often these appear with closely-spaced natural frequencies. Owing to the coupling among modes with closely-spaced natural frequencies, each eigenvector corresponding to closely-spaced eigenvalues is ill-conditioned that may cause structural instability. The subspace to an invariant subspace corresponding to closely-spaced eigenvalues is well-conditioned, so a method is presented to design the feedback control law of intelligent structures with closely-spaced eigenvalues in this paper. The main steps are as follows: firstly, the system with closely-spaced eigenvalues is transformed into that with repeated eigenvalues by the spectral decomposition method; secondly, the computation for the linear combination of eigenvectors corresponding to repeated eigenvalues is obtained; thirdly, the feedback control law is designed on the basis of the system with repeated eigenvalues; fourthly, the system with closely-spaced eigenvalues is regarded as perturbed system on the basis of the system with repeated eigenvalues; finally, the feedback control law is applied to the original system, the first order perturbations of eigenvalues are discussed when the parameter modifications of the system are introduced. Numerical examples are given to demonstrate the application of the present method.

High-order, closely-spaced modal parameter estimation using wavelet analysis

  • Le, Thai-Hoa;Caracoglia, Luca
    • Structural Engineering and Mechanics
    • /
    • 제56권3호
    • /
    • pp.423-442
    • /
    • 2015
  • This study examines the wavelet transform for output-only system identification of ambient excited engineering structures with emphasis on its utilization for modal parameter estimation of high-order and closely-spaced modes. Sophisticated time-frequency resolution analysis has been carried out by employing the modified complex Morlet wavelet function for better adaption and flexibility of the time-frequency resolution to extract two closely-spaced frequencies. Furthermore, bandwidth refinement techniques such as a bandwidth resolution adaptation, a broadband filtering technique and a narrowband filtering one have been proposed in the study for the special treatments of high-order and closely-spaced modal parameter estimation. Ambient responses of a 5-story steel frame building have been used in the numerical example, using the proposed bandwidth refinement techniques, for estimating the modal parameters of the high-order and closely-spaced modes. The first five natural frequencies and damping ratios of the structure have been estimated; furthermore, the comparison among the various proposed bandwidth refinement techniques has also been examined.

Identification of modal damping ratios of structures with closely spaced modal frequencies

  • Chen, J.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제14권4호
    • /
    • pp.417-434
    • /
    • 2002
  • This paper explores the possibility of using a combination of the empirical mode decomposition (EMD) and the Hilbert transform (HT), termed the Hilbert-Huang transform (HHT) method, to identify the modal damping ratios of the structure with closely spaced modal frequencies. The principle of the HHT method and the procedure of using the HHT method for modal damping ratio identification are briefly introduced first. The dynamic response of a two-degrees-of-freedom (2DOF) system under an impact load is then computed for a wide range of dynamic properties from well-separated modal frequencies to very closely spaced modal frequencies. The natural frequencies and modal damping ratios identified by the HHT method are compared with the theoretical values and those identified using the fast Fourier transform (FFT) method. The results show that the HHT method is superior to the FFT method in the identification of modal damping ratios of the structure with closely spaced modes of vibration. Finally, a 36-storey shear building with a 4-storey light appendage, having closely spaced modal frequencies and subjected to an ambient ground motion, is analyzed. The modal damping ratios identified by the HHT method in conjunction with the random decrement technique (RDT) are much better than those obtained by the FFT method. The HHT method performing in the frequency-time domain seems to be a promising tool for system identification of civil engineering structures.

축소모형실험을 통한 근접터널의 거동에 관한 연구 (A Study on the Behavior of a Closely-Spaced Tunnel by Using Scaled Model Tests)

  • 안현호;최정인;이석원;심성현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.189-198
    • /
    • 2008
  • Lots of roadway tunnel have been almost constructed in forms of closely-spaced tunnel in korea. If closely-spaced tunnel is not constructed at a sufficient distance between tunnels, the problem of stability can occur. However, the case that can not secure a sufficient distance between tunnels can occur due to a difficulty in buying a lot and an issue of popular complaint and environmental disruption. Generally, tunnels are not influenced by each other when a center distance between tunnels is two times longer than tunnel diameter under the complete elastic ground and five times under the soft ground. In this study, the scaled model tests of closely-spaced tunnel by using homogeneous material were performed and induced displacements were measured around the tunnel openings during excavation. The influence of distance between tunnels on the behavior of closely-spaced tunnel was investigated.

  • PDF

입자 유동 해석(PFC)을 통한 근접터널의 거동에 관한 연구 (A Study on the Behavior of a Closely-spaced Tunnel by Using Particle Flow Code)

  • 서병욱;조선아;정선아;이석원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.159-169
    • /
    • 2008
  • In general, it is considered that a pillar between closely-spaced tunnel is sensitive for stress concentration. Stability of a pillar is key factor for excavation of closely-spaced tunnel. In this paper, the study is focused on tracing the behaviors, displacement and plotting damages around tunnels that is modelled with Particle Flow Code, $PFC^{2D}$. Parametric study was performed with changing distance between center of tunnels and coefficient of earth pressure(K). Scaled-model tests were also carried out to validate a numerical analysis model. It was found that $PFC^{2D}$ could show dynamic visualized result in quite good agreement with the experimental test.

  • PDF

근접터널의 설계개념 및 해석기법에 대한 연구 (A study on design concept and analysis method of closely spaced tunnels)

  • 김상환
    • 한국터널지하공간학회 논문집
    • /
    • 제5권1호
    • /
    • pp.33-42
    • /
    • 2003
  • 최근 도심지역에서는 지하철과 같은 주요교통 수단으로 터널의 이용이 날로 증가되고 있는 추세에 있다. 터널 주변의 응력 및 변형상태는 새로운 터널건설에 의하여 변화되어 진다. 따라서, 근접터널에 대한 영향요소에 대한 연구 및 고찰은 필수적이다. 이 본문은 근접터널의 설계개념 및 분석기법에 대한 연구로써 신설터널의 건설로 인한 근법터널의 영향 및 상호거동에 대하여 고찰하였다. 특히 터널의 간격, 기하학적 위치, 라이닝의 강성 및 침하 등에 대하여 이론적 이해를 통하여 설계와 분석기법에 대하여 제안하였다. 결과적으로 이 논문을 통하여 향후 근접터널 설계시 보다 이론적이고 기술적인 접근을 위한 방향제시 및 해석방법등 기술향상을 위하여 도모 할 수 있을 것이다.

  • PDF

Optimal placement and tuning of multiple tuned mass dampers for suppressing multi-mode structural response

  • Warnitchai, Pennung;Hoang, Nam
    • Smart Structures and Systems
    • /
    • 제2권1호
    • /
    • pp.1-24
    • /
    • 2006
  • The optimal design of multiple tuned mass dampers (multiple TMD's) to suppress multi-mode structural response of beams and floor structures was investigated. A new method using a numerical optimizer, which can effectively handle a large number of design variables, was employed to search for both optimal placement and tuning of TMD's for these structures under wide-band loading. The first design problem considered was vibration control of a simple beam using 10 TMD's. The results confirmed that for structures with widelyspaced natural frequencies, multiple TMD's can be adequately designed by treating each structural vibration mode as an equivalent SDOF system. Next, the control of a beam structure with two closely-spaced natural frequencies was investigated. The results showed that the most effective multiple TMD's have their natural frequencies distributed over a range covering the two controlled structural frequencies and have low damping ratios. Moreover, a single TMD can also be made effective in controlling two modes with closely spaced frequencies by a newly identified control mechanism, but the effectiveness can be greatly impaired when the loading position changes. Finally, a realistic problem of a large floor structure with 5 closely spaced frequencies was presented. The acceleration responses at 5 positions on the floor excited by 3 wide-band forces were simultaneously suppressed using 10 TMD's. The obtained multiple TMD's were shown to be very effective and robust.

근접한 이중대역 신호에 대한 디지털 전치왜곡 기법 (Digital Predistortion for Closely Spaced Dual-Band Signals)

  • 정의림;오주현;김도경
    • 한국정보통신학회논문지
    • /
    • 제22권12호
    • /
    • pp.1684-1690
    • /
    • 2018
  • 근접한 이중대역 신호에 대한 새로운 디지털 전치왜곡 기법을 제안한다. 본 논문에서 고려하는 시스템은 이중대역 신호를 한 개의 전력증폭기로 증폭하는 송신기이다. 이 경우 전력증폭기 출력신호는 두 대역 신호의 교차변조 및 상호변조에 의해 왜곡이 발생한다. 특히 두 대역이 가까울 때에는 각 대역에서 상호변조에 의해 발행한 스펙트럼이 서로 겹칠 수 있고 이는 전치왜곡 성능을 저하시킨다. 이러한 문제를 해결하기 위해서 제안하는 기법은 먼저 전력증폭기 특성을 추정하고 이렇게 추정한 전력증폭기 특성을 바탕으로 전치왜곡 계수를 추출한다. 이러한 두 단계를 통해 전치왜곡 계수를 구하면 근접한 이중대역 신호에 대해서도 서로 간섭 없이 전치왜곡이 동작할 수 있다. 제안하는 기법은 컴퓨터 모의실험을 통해 검증하는데, 모의실험 결과에 따르면 제안하는 기법이 기존의 이중대역 전치왜곡 방법보다 우수한 성능을 보인다.

입자간의 상호작용으로 인한 입자의 운동 및 증발에 미치는 영향 (Influences on the Droplet Dynamics and Evaporation due to Closely Spaced Droplet Interaction)

  • 이효진
    • 대한기계학회논문집
    • /
    • 제16권9호
    • /
    • pp.1770-1779
    • /
    • 1992
  • The present study investigated dynamically and thermally interacting droplets in a closely spaced tandem array. By measuring the velocity and diameter of the droplet traveling along the isothermal vertical plate drag coefficients and vaporization rates of droplets at certain location were obtained. During the experiment initial droplet spacings were less than 5, and initial droplet diameters were ranged between 280 .mu.m and 700 .mu.m Drag coefficients on closely spaced droplets were placed far below the standard drag coefficient, for which it was caused turbulence induced from aforelocating droplets also narrow spaces among droplets restricted heat transfer to droplets from hot gas flow. In addition evaporated vapor entrapted between droplets was major factor in delaying droplet vaporization. With the experimental results the drag coefficient was correlated with respect to Reynolds number for the droplet as follows : $c_{D}$ =2.4/Red.$^{0.37}$

단일텐던 및 복수텐던이 설치된 프리스트레스트 콘크리트 부재의 정착부 거동 연구 (Mechanical Behavior of Anchorage Zones in Prestressed Concrete Members with Single and Closely-Spaced Anchorages)

  • 오병환;임동환;유승운
    • 대한토목학회논문집
    • /
    • 제14권6호
    • /
    • pp.1329-1339
    • /
    • 1994
  • 본 논문은 복수 정착구가 서로 인접하여 설치되었을 경우의 정착부 거동 및 국부응력 분포특성을 규명함에 목적이 있으며, 이를 위하여 단일텐던 및 복수텐던이 설치된 프리스트레스 콘크리트부재에 대한 실험연구가 수행되었다. 위의 실험연구 결과 정착부 파괴는 단일 및 복수텐던 설치부재 모두 텐던을 따라가는 균열에 의해 시작되며, 먼저 정착된 텐던 정착부 주변의 인장응력은 인접해서 긴장되는 텐던의 압축응력 발생효과로 인하여 균열하중에 대한 저항성이 개선됨이 밝혀졌다. 본 논문에서는 복수텐던 부재의 정착부 주위의 변형도 분포와 균열하중 등을 단일텐던 부재의 경우와 비교분석하여 제시하였으며, 복수텐던부재의 파괴기구도 규명하였다.

  • PDF