• 제목/요약/키워드: closed-loop identification

검색결과 74건 처리시간 0.044초

궤환 제어를 이용한 시스템 규명 (System identification using the feedback loop)

  • 정훈상;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.409-412
    • /
    • 2001
  • Identification of systems operating in closed loop has long been of prime interest in industrial applications. The fundamental problem with closed-loop data is the correlation between the unmeasurable noise and the input. This is the reason why several methods that work in open loop fail when applied to closed-loop data. The prediction error based approaches to the closed-loop system are divided to direct method and indirect method. Both of direct and indirect methods are known to be applied to the closed-loop data without critical modification. But the direct method induces the bias error in the experimental frequency response function and this bias error may deteriorates the parameter estimation performance

  • PDF

Identification of the process in closed-loop control system

  • Oura, Kunihiko;Akizuki, Kageo;Hanazaki, Izumi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.140-145
    • /
    • 1994
  • In this paper, we consider a problem to estimate process parameters using input-output data collected from the process operating in closed-loop control system. When orders and delay-time of the process are known correctly, under some conditions of identifying experiments, it is reported that accurate identification results can be obtained by applying prediction error method. To get accurate estimates, it is necessary to know orders and delay-time of the process. It is difficult to determine them in closed-loop identification, because ill-condition for identification are easily caused by selection of unsuitable order or delay time. Furthermore, the procedures to select orders and delay-time in open-loop identification aren't always available in closed-loop identification. The purpose of this paper is to determine a delay-time under suitable assumption that order of the process are known as the first step.

  • PDF

폐로식별기법에 의한 TRMS 모델링 (Modeling for Twin Rotor System Using CLID)

  • 이정경;권오규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.644-646
    • /
    • 2004
  • The closed loop identification(CLID) is a very useful method for on-line applications since it can identify the plant in the closed-loop system composed of the plant and the controller. There are some literatures on CLID, but they and mainly focused on SISO(Single-Input/Single-Output) problem. In this paper, a CLID method is proposed for MIMO(Multi-Input/Multi-Output) systems. The CLID method is applied to a MIMO benchmark plant, TRMS(Twin-Rotor MIMO System). To illustrate the performance of the closed-loop system identification., unit step responses in the TRMS are represented and compared with the open-loop identification via some simulation.

  • PDF

신경 회로망을 이용한 증기 발생기의 폐 루프 시스템 규명 (Closed Loop System Identification of Steam Generator Using Neural Networks)

  • 박종호;한후석;정길도
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.78-86
    • /
    • 1999
  • The improvement of the water level control is important since it will prevent the steam generator trip so that improve the reliability and credibility of operation system. In this paper, the closed loop system identification is performed which can be used for the system monitoring and prediction of the system response. The model also can be used for the prediction control. Irving model is used as a steam generator model. The plant is an open loop unstable and non-minimum phase system. Fuzzy controller stabilize the system and the stable controller stabilize the system and the stable closed loop system is identified using neural networks. The obtained neural network model is validated using the untrained input and output. The results of computer simulation show the obtained Neural Network model represents the closed loop system well.

  • PDF

PID Control of Poly-butadiene Latex(PBL) Reactor Based on Closed-loop Identification and Genetic Algorithm

  • Kwon, Tae-In;Yeo, Yeong-Koo;Lee, Kwang Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2600-2605
    • /
    • 2003
  • The PBL (Poly-butadiene Latex) production process is a typical batch process. Changes of the reactor characteristics due to the accumulated scaling with the increase of batch cycles require adaptive tuning of the PID controller being used. In this work we propose a tuning method for PID controllers based on the closed-loop identification and the genetic algorithm (GA) and apply it to control the PBL process. An approximated process transfer function for the PBL reactor is obtained from the closed-loop data using a suitable closed-loop identification method. Tuning is performed by GA optimization in which the objective function is given by ITAE for the setpoint change. The proposed tuning method showed good control performance in actual operations.

  • PDF

On order determination in identification of closed-loop systems

  • Oura, Kunihiko;Akizuki, Kageo;Hanazaki, Izumi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.480-483
    • /
    • 1995
  • Identification of a process in closed-loop control system is an important problem in practice. This paper deals with parameter estimation using input-output data of the process operating in a closed-loop system. It is necessary to determine orders and delay-time to get consistent estimators by least square method for input-output data collected from the process. The authors considered a problem to determine delay-time in the condition that orders were known, in last KACC. So we extend the range to determine orders and delay-time in this paper.

  • PDF

컨버터의 폐루프 식별 및 제어기 설계 (Closed-loop Identification and Controller Design for a Converter)

  • 윤경한;임연수;김려화;김재진;김영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1632-1633
    • /
    • 2007
  • This paper presents a new method of designing digital controller based on closed-loop identification of a pulse width modulation (PWM) converter system. We consider the control system structure which is composed of both current control loop and voltage control loop. The current controller can be designed independently of voltage loop. Whereas voltage controller can not do easily due to the PWM switching component which is nonlinear in nature. Furthermore, the control objective of inner loop is to track the sine wave of 60 Hz, but the outer loop shall maintain the constant DC voltage irrespective to load change. To systematically design outer loop controller, we propose a method finding linear approximate model of the nonlinear inner loop part including current controller by closed loop identification. Based on the identified model, we show that a simple digital voltage controller can be directly designed and it has good performance.

  • PDF

뉴럴 네트워크를 이용한 동적 시스템 식별과 제어 (Identification and Control of Dynamical System Using Neural Networks)

  • 박성욱;이동현;서보혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.290-292
    • /
    • 1993
  • This paper investigates the identification of discrete time nonlinear system using neural networks with two hidden layers. A New learning method of both NNI and NNC is proposed. For control of the dynamical system we use two neural networks, one for identification and the other for control, and proposed NN control system is based on a framework of MRC. We define a closed loop error. In the proposed learning method, the identification error and the closed loop error are utilized to train the NNI, whareas the control error and the closed loop error are used to train the NNC, The simulation results show that the identification and control schemes suggested are practically feasible and effective.

  • PDF

An Experimental Application of Observer/controller Identification Algorithm to the System Identification of Inherently Unstable Systems

  • Park, Mun-Soo;Yang, Dong-Hoon;Hong, Suk-Kyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.63.4-63
    • /
    • 2002
  • $\textbullet$ Closed System Identification for inherently unstable systems $\textbullet$ Application of Observer/controller Identification (OCID) algorithm to those systems $\textbullet$ An open-loop system model with corresponding controller and observer gains are identified using OCID $\textbullet$ Experimental example of the OCID algorithm for an inverted pendulum system operating in closed-loop $\textbullet$ Modal analysis and time response to the added distrubance are presented to evaluate the performance of the OCID algorithm.

  • PDF

AC 서보 전동기 시스템의 상태공간 모델 식별에 관한 연구 (A Study on State-Space Model Identification of AC Servo Motor System)

  • 이태훈;김상환;송봉철;원충연;이상석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.199-204
    • /
    • 2000
  • Generally, The systems are so complex that it not possible to obtain reasonable model using physical insight. Also a model based on physical insight contains a number of unknown parameters even if the structure is derived from physical laws. To solve these problems, the systems identification is described in this paper. So, AC servo motor system which has both open loop and closed loop is selected as an example for identification. A state-space model of AC servo motor system is identified through open loop experiment and identified through closed loop experiment and using pole placement integral controller to open loop system. As the results, From ARMA model, We have obtained continuous-time state space model.

  • PDF