Methods for Measurement of Methane and Nitrous Oxide Emissions from Agricultural Fields (경작지(耕作地)에서 메탄 및 아산화질소(亞酸化窒素) 배출량(排出量) 측정방법(測定方法))

  • Shin, Yong-Kwang;Kim, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.3
    • /
    • pp.359-372
    • /
    • 1994
  • A simplified closed static chamber method was devised for measurement of methane flux from paddy fields. Compared to automatic methane measuring system(AMMS) this chamber method provides availability with moderate costs of setup and maintenance, while it also provides the time-effectiveness compared to other closed top-type chamber method. It accomodates 30 chambers within 2 hours sampling period with two persons. And it provide a rapid and accurate analysis of methane, 30-40 samples per hour. Modified method for $N_2O$ measurements provides a precise and accurate analysis of nitrous oxide without upgrading additional heating zones for gas sampling(switching) valves.

  • PDF

An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor) (혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구)

  • Lee, Yun-ho;Lee, Seokwon;Lee, Kyoungho;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.

A Simplified Closed Static Chamber Method for Measuring Methane Flux in Paddy Soils (논토양(土壤)의 메탄 배출(排出) 측정(測定)을 위한 간역폐쇄정태(簡易閉鎖靜態) Chamber법(法))

  • Shin, Yong-Kwang;Lee, Yang-Soo;Yun, Seong-Ho;Park, Moo-Eon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • Various factors such as sampling height in the chamber, sampling interval, sampling time at daytime and the effects of pedoturbation on methane emission during chamber installation were evaluated using a simplified closed static chamber method to measure methane flux in paddy soils. Sampling height of the chamber for representative samples was 65cm. An additional DC fan was required to attain an even methane gradient in the chamber. Considering the change of methane concentration and air temperature in the chamber, sampling is recommended to finish within 30 minutes after starting sampling. The aim of setting DC fan in the chamber was to get the thermal equilibrium in the chamber as well as the representative samples. Suitable time to collect the gas samples representing the day's methane flux was 0900~1200 hours. Gas sampling was possible even after installation of small chambers if the elapsed time was more than 6 hours and supporting stand would be to be added to minimize pedoturbation.

  • PDF

The effect of ignition position on combustion in the chamber with swirl flow (선회류가 있는 연소실의 연소에 미치는 점화위치의 영향)

  • 이종태
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.42-53
    • /
    • 1988
  • The effects of ignition position on combustion in a chamber with swirl flow were investigated by use of hot wire anemometer, high speed schlieren photography, and chamber pressure measurement. In experiments, the closed-constant volume combustion chamber was used, and the swirl was formed unsteadily by suction of external fluid after reducing pressure in the chamber. Results show that the effect of ignition position on combustion depends on the flow state and the flame propagation distance corresponding to each ignition position. Also, the effect of combustion promoting increases as an ignition position moves from the center of chamber to the outside, but maximum burning pressure was obtained at the position that is the shortest flame propagation distance.

  • PDF

Combustion Characteristics associated with a Swirl Chamber and Nozzle Length of Coaxial Swirl Injectors (동축스월분사기에서 와류실 유무 및 노즐길이에 따른 연소특성 변화)

  • Lim Byoung-Jik;Seo Seong-Hyeon;Choi Hwan-Seok;Choi Young-Hwan;Lee Seok-Jin;Kim Yoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.335-340
    • /
    • 2005
  • A study on the variation of combustion characteristics by injector geometries was conducted. Coaxial swirl injectors were used. Existence of swirl chamber and variation of a nozzle length become key parameters. Injectors were identified as open, closed and mixed type by existence of swirl chamber. Variation of nozzle length was made extruding the both nozzle along the axis while other design parameters remain the same. A uni-element combustor with ablative material liner and a water cooled nozzle made by oxygen free copper with outer stainless steel casing were used.

  • PDF

Measurements of Nitrous Oxide Emission from Upland Agricultural Soil by a Closed Chamber System and Soil Controlling Factors (Closed chamber를 이용한 발 토양으로부터의 nitrous oxide 배출량 측정 및 토양인자들과의 상관성에 관한 연구)

  • 오진만;김득수
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.170-172
    • /
    • 2002
  • 현재 대기 조성의 변화는 과거(산업혁명 전)와는 달리 온실기체 증가(increasing the Green House Gas, CH$_4$, $CO_2$, $N_2$O) 및 기타 대기오염물질들(NOx, SOx, $O_3$등)의 조성증가로 인해 직.간접적으로 인간의 활동 및 건강에 영향을 끼치고 있다. 온실기체를 예를 들어, $CO_2$의 경우, 산업혁명 전과 비교하여 약 30%정도 증가하였으며, CH$_4$, $N_2$O는 각각 145%, 15%증가하였다(A.R Mosier 1998). (중략)

  • PDF

Intercomparison of Chamber Methods for Soil Respiration Measurement in a Phytotron System (식물 환경 조절 시스템에서의 토양 호흡 관측 챔버법의 비교 실험)

  • Chae Namyi;Kim Rae-Hyun;Hwang Taehee;Suh Sang-Uk;Lee Jae-Seok;Son Yowhan;Lee Dowon;Kim Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.107-114
    • /
    • 2005
  • Soil CO₂ emission is one of the primary components in carbon balance of terrestrial ecosystems. In soil CO₂ flux measurements, chamber method is currently the most common technique. Prior to compare or synthesize the data collected from different chamber methods, potential biases must be quantified for each measurement system. We have conducted an intercomparison experiment among four closed dynamic chamber systems and an automatic open-closed chamber system in a temperature-controlled phytotron. Due to the disturbed CO₂ concentrations inside the phytotron during the measurements with closed dynamic chambers and the changes in soil water content, the interpretation of the data was difficult to quantify the biases of individual methods. However, the experiment provided not only valuable information on the performance characteristics of the five instruments to varying soil temperature and CO₂ concentration but also useful insights for better designs and strategy for future intercomparison in a controlled environment.

Development of Constant Delivery Micro Pump in a Variable Pressure Environment for Intrathecal Drug Administration System (레져버에 압력이 가해지는 환경에서의 미소 정량 토출 펌프의 개발)

  • Lee, Tae Gyeong;Lee, Cheol Su;Jung, Yu Seok;Park, Gyeong Geun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.4
    • /
    • pp.387-394
    • /
    • 2017
  • This paper develops a pump system for patient with chronic pain or cancer. The pump module is consists of two micro-valve and membrane. The micro-valve is operated by a solenoid. With two solenoid valves which are connected via a drug transport line, the inlet and outlet are completely blocked. A silicon rubber membrane located between the two valves makes the flow-rate constant without any backflow. This pump module can control the flow-rate of drugs by controlling the time that the valves are opened and closed. The reservoir consists of a drug chamber and a gas chamber. As the gas chamber encloses the drug chamber, propellant gas which is injected into the gas chamber pressurizes the drug chamber regardless of volume of the drug chamber. To design the pump module, analysis a constant efficiency test, and accuracy test for the pump module were conducted.

Study on the Characteristics of Turbopump+Gas generator Closed-loop coupled test (터보펌프+가스발생기 폐회로 연계시험 특성 연구)

  • Kim, Seung-Han;Nam, Chang-Ho;Kim, Cheul-Woong;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.38-41
    • /
    • 2009
  • For the technology development of LOx/kerosene liquid rocket engine, turbopump-gas generator closed-loop coupled tests using 30tonf main engine components such as turbopump and gas generator except combustion chamber are performed. In the engine system operation environment, simulating combustion chamber by flow control units, the chill-down procedure, startup characteristics, nominal operability and smooth shutdown of turbopump+gas generator closed-loop coupled Test Plant are successfully confirmed. The serviceability of the turbopump and gas generator are evaluated. The feed-back control system for the turbopump rotational speed and gas generator mixture ratio are also verified. The results of closed-loop coupled test will be used as the technology development for the liquid rocket engine.

  • PDF

Design and Performance Test of a Closed Loop Thermal Control System for Thermal Vacuum Chamber (열진공 챔버용 폐회로 열제어시스템 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Jung, Sanghun;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.88-97
    • /
    • 2016
  • A closed loop thermal control system simulates space thermal environment to verify the satellites' functionality in extremely cold/hot temperature. It is composed of a cryogenic blower, thermal shroud, heater, cryogenic valves. This paper presents an overview of closed loop thermal control system's design parameter and test results for control parameter. A capacity of blower is calculated through energy balance equation and an advantage/disadvantage for a shroud material and a type was analysed. The thermal control system is controlled by a constant density of fluid in the system. A requested performance of closed loop thermal control system was verified by measuring a homogeneity and stability of shroud through control parameter such as density and RPM of blower.