• 제목/요약/키워드: clear heat

검색결과 355건 처리시간 0.028초

기상 조건에 따른 도시 캐노피 모형의 성능 비교 (Performance Comparison of an Urban Canopy Model under Different Meteorological Conditions)

  • 유영희;백종진;이상현
    • 대기
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2012
  • The performances of the Seoul National University Urban Canopy Model (SNUUCM) under different meteorological conditions (clear, cloudy, and rainy conditions) in summertime are compared using observation dataset obtained at an urban site. The daily-averaged net radiation, sensible heat flux, and storage heat flux are largest in clear days and smallest in rainy days, but the daily-averaged latent heat flux is similar among clear, cloudy, and rainy days. That is, the ratio of latent heat flux to net radiation increases in order of clear, cloudy, and rainy conditions. In general, the performance of the SNUUCM is better in clear days than in cloudy or rainy days. However, the performance in simulating sensible heat flux in clear days is as poor as that in rainy days. For all the meteorological conditions, the performance in simulating latent heat flux is worst among the performances in simulating net radiation, sensible heat flux, and latent heat flux. The normalized mean error for latent heat flux is largest in rainy days in which the relative importance of latent heat flux in the surface energy balance becomes greatest among the three conditions. This study suggests that improvements to the parameterization of processes that are related to latent heat flux are particularly needed.

대규모 주택단지내의 인공구조물에 의한 승온화효과에 관한 연구 (On the Warming Effects due to Artificial Constructions in a Large Housing Complex)

  • 김해동;이송옥;구현숙
    • 한국환경과학회지
    • /
    • 제12권7호
    • /
    • pp.705-713
    • /
    • 2003
  • In mid-August 2002, under clear summer pressure patterns, we carried out an intensive meteorological observation to examine the warming effects due to artificial constructions in a large housing complex. We set an automatic weather system(AWS) at two places in a bare soil surface within a limited development district and an asphalt surface within a large apartment residence area, respectively. As a result of observation, it became clear that the difference of the surface air(ground) temperature between the bare soil surface and its peripheral asphalt area reached about 4$^{\circ}C$(13$^{\circ}C$) at the maximum from diurnal variation of surface temperatures on AWS data. Through the heat balance analysis using measurement data, it became clear that the thermal conditions at two places are dependent on the properties of surface material. The latent heat flux over the bare soil surface reached to about 300 W/㎡, which is more than a half of net radiation during the daytime. On the other hand, it was nearly zero over the asphalt surface. Hence, the sensible heat flux over the asphalt surface was far more than that of the bare soil surface. The sensible heat flux over the asphalt surface showed about 20∼30 W/㎡ during the night. It was released from asphalt surface which have far more heat capacity than that of bare soil surface.

청열(淸熱)효능을 지닌 약선재료의 기미론(氣味論)적 의미와 식품학적 특성 (Qi-Flavor Theory' Meaning, Nutrient Content and Anti-Oxidative Activity of Oriental Medicinal Materials with Clear Heat Effect)

  • 박성혜
    • 한국식생활문화학회지
    • /
    • 제31권1호
    • /
    • pp.42-50
    • /
    • 2016
  • Traditionally, food and medicines are considered as having common roots. That is, their energies share the same source (藥食同源), which has created a unique food culture, and nurtured a unique academic area of dietary medicine (藥膳食料學). This study aimed to develop a desirable dietary life-style based on the oriental dietary medicine theorem originated from the schema of four qi as well as five flavors of foods (四氣五味), originated from the yin-yang and five phase theory based on a clear understanding of a modern point of view, and experimental analysis of nutrients and dietary effects of clear heat effect materials. This study can promote more healthy life-styles and prevent adult diseases by following oriental dietary medicine theory. We should develop a Yack-sun theory and dietary culture that is suitable for physical and genetic health.

중풍(中風)의 치료(治療)에 있어 청열법(淸熱法)에 대(對)한 문헌적(文獻的) 고찰(考察) (The literatual study on the therapy for clearing away heat with apoplexy therapy)

  • 강화정;문병순
    • 한국한의학연구원논문집
    • /
    • 제2권1호
    • /
    • pp.26-39
    • /
    • 1996
  • The literatual study on the therapy for clearing away heat with apoplexy therapy, the result were obstained as follows. 1. In apoplexy therapy, therapy for clearing away heat is used excessive heart - fire by overacting of the five emotions, liver fire, deficiency of kidney - fluid, wind - heat. 2. The fire of aetiology of apoplexy is used therapy for clearing away eat, in aspect of viscera and bowels, divied into heart - fire, liver - fire, deficiency fie of kidney yin, wetness - phlegm of spleen heat. The treatment is clear away heart - fire, clear away liver - fire, clear away spleen - heat and sthenic water. 3. Symptom of excessiveness symptom - complex is used therapy for clearing away heat that are fever, flushed face, halitosis, heart burn, easy anger, apoplestic stroke, unconsciouness, trismus, paralysis, constipation, red tongue with yellow coat, taut - smooth pulse or full - rapid pulse and symptom of insufficiency symptom - complex that are dizziness, tinitus, blurring of vision, deficiency sleeping, dreaminess, lassitude of the loins and legs, hemiplegia, red tongue with white coat or thin - yellow coat taut - thready - rapid pulse. 4. Therapy for norish vital essence - clearing away heat is availed in excessive fire caused by deficiency of yin of the liver and kidney, therapy for break through phlegm - clearing away heat in stagnant heat therapy for waking up a patient from unconsciousness - clearing away heat in yang type sthenia - syndrom of coma of apoplexy involving viscera and bowels. 5. Commonly used recipes of therapy for clearing away heat are Yang gyolksan(凉膈散), Bang pongtongseongsan(防風通聖散), Sotongseongsan(小通聖散), Jibodan(至寶丹), Supungsungisan(搜風順氣散), Woowhangchengshimwhan(牛黃淸心丸), Chengungsekgong(川芎石膏湯), Samwhatang(三化湯) etc in excessiveness symptom- complex, and are Yukmijiwhangweon(六味地黃元), Jiwhangtang(地黃湯), Palmiji whangtang(八味地黃湯), Samultanggagam(四物湯加減) etc in insufficiency symptom - complex.

  • PDF

A Numerical Study on the Smoke Behavior by Solar Radiation through Ceiling Glass in Atrium Fires

  • Jeong, Jin-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권3호
    • /
    • pp.117-128
    • /
    • 2002
  • This paper describes the smoke filling process of a fire field model based on a self-deve-loped SMEP (Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy production term. Also it solves the radiation equation using the discrete ordinates method. Compressibility is assumed and the perfect gas law is used. Comparison of the calculated upper-layer average tempera-ture and smoke layer clear height with the zone models has shown reasonable agreement. The zone models used are the CFAST and the NBTC one-room. For atrium fires with ceiling glass the ceiling heat flux by solar heat causes a high smoke temperature near the ceiling. However, it has no effect on the smoke movement such as the smoke layer clear heights that are important in fire safety. In conclusion, the smoke layer clear heights that are important in evacuation activity except the early of a fire were not as sensitive as the smoke layer tem-perature to the nature of ceiling heat flux condition. Thus, a fire sensor in atrium with ceiling glass has to consider these phenomena.

태양에너지 해수담수화 시스템 일일 운전 특성 (Daily Operating Characteristics of Desalination System with Solar Energy)

  • 곽희열;주홍진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.262-265
    • /
    • 2009
  • This study was carried out to evaluate the clear day operating performances for the decentralized desalination system with the solar thermal system and the photovoltaic power system. In a clear day, we used a solar thermal system as heat source of the single-stage fresh water generator with plate-type heat exchangers and a photovoltaic power system as electric source for hydraulic pumps. The demonstration system generation was designed and installed at Jeju-island in 2006. The system was comprised of the desalination unit with daily fresh water capacity designed as $2m^3$, a $120m^3$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5.2kW photovoltaic power generation to supply the electricity of hydraulic pumps for the heat medium fluids. In a clear day, solar irradiance daily averaged was measured $518W/m^3$, the daily fresh water yield showed that about 565 liter.

  • PDF

대구지역의 기상조건에 따른 도시열섬강도의 계절별 변화특성 (On the Seasonal Variation of Urban Heat Island Intensity According to Meteorological Condition in Daegu)

  • 안지숙;김해동
    • 한국환경과학회지
    • /
    • 제15권6호
    • /
    • pp.527-532
    • /
    • 2006
  • The purpose of this study is to clarify the characteristic of urban heat island intensity in urban area formed at a basin. Thermal environments for basin-type cities are influenced by significant topographic relief winds. In this study, we analyzed the diurnal variations of the heat island intensity according to meteorological condition and season using AWS(Automatic Weather observation System) data in Daegu Metropolitan area for 1 year(3/April, 2003 $\sim$ 2/April, 2004). In this study, we defined the urban heat island intensity as the air temperature difference between two points, the downtown and the suburban area. The suburban area is located at valley mouth around the western tip of Daegu. The results are summarized as follows; 1. The maximum heat island intensity was recorded at early morning under the meteorological conditions, calm and clear 2. The heat island intensity was strong in the order of winter, fall, spring and summer. 3. The heat island intensity came out minus values in the afternoon. This phenomenon is known as a com mon for basin-type cities. 4. The heat island intensity was twice or more in clear and calm than not so.

대구 앞산 달비골의 국지풍 특성에 관한 관측적 연구 (Observational Study on the Local Wind of the Dalbi-Valley Located at Ap-Mountain in Daegu)

  • 구현숙;권병혁;김해동
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.73-79
    • /
    • 2007
  • The purpose of this study is to clarify the effect of mountain-valley wind on heat island formed in urban area which is located around valley mouth. The meteorological observations were carried out over the Dalbi-valley under a clear summer pressure patterns, and some consideration were tried from the results. In order to make clear the climatological characteristics and air-mass modification process of the mountain-valley wind over the valley, the meteorological observations were done simultaneously at two points. The observational points were located at the breast and valley mouth parts, respectively. The results were as follows: First, it was found that the valley wind was observed through the daytime, and it was replaced by a mountain wind after sunset. Second, the heat budget is also investigated with observation data. The sensible heat flux over the breast of Dalbi-valley reached to about $200 W/m^2$ during daytime, which is a little more than one third of net radiation. On the other hand, the sensible heat flux represented negative values during nighttime. But the sensible heat flux over the valley mouth covered by asphalt showed plus value(about $20{\sim}30 W/m^2$) during the nighttime.

소양인체질병증 임상진료지침: 음허오열병 (Clinical Practice Guideline for Soyangin Disease of Sasang Constitutional Medicine: Yin-Deficit Diurnal-Heat (Eumheo-oyeol) symptomatology)

  • 유준상;이의주
    • 사상체질의학회지
    • /
    • 제26권3호
    • /
    • pp.272-280
    • /
    • 2014
  • Objectives This research was carried out to establish the clinical practice guideline(CPG) for Yin-Deficit Diurnal-Heat (Eumheo-oyeol) symptomatology of Soyangin disease. Methods Dongeuisusebowon(sinchuk edition) and several kinds of literatures including journal articles concerning this symptomatology of Soyangin disease were collected and classified. Sasang constitutional specialists' conference was held to make an agreement on the conflicting issues as well. Consensus was drawn as a result of the conference. Results & Conclusions 3 papers were selected as an inclusion and exclusion criteria for the relevant articles to Yin-Deficit Diurnal-Heat (Eumheo-oyeol) symptomatology of Soyangin disease. Yin-Deficit Diurnal-Heat (Eumheo-oyeol) symptomatology consists of two aspects : Yin-Deficit Diurnal-Heat (Eumheo-oyeol) severe pattern and Yin-Deficit Diurnal-Heat (Eumheo-oyeol) critical pattern. In Yin-Deficit Diurnal-Heat (Eumheo-oyeol) severe pattern contains 1 disease, namely, Clear Yang Depletion of Large Intestine (Daejang-cheongyang Moson) pattern (Lower wasting-thirst (Haso) pattern). In Yin-Deficit Diurnal-Heat (Eumheo-oyeol) critical pattern contains 2 diseases, Yin-Deficit Diurnal-Heat (Eumheo-oyeol) pattern and Yin-Deficit Diurnal-Heat (Eumheo-oyeol) advanced pattern. Yin-Deficit Diurnal-Heat (Eumheo-oyeol) symptomatology has several kinds of symptoms like dry mouth, disliking to drink much water, diurnal body fever, coldness on the back and nausea as well as body fever, chest discomfort, constipation or dry stool as a common symptoms of Interior Heat disease. Clear Yang Depletion of Large Intestine (Daejang-cheongyang Moson) pattern (Lower wasting-thirst (Haso) pattern) has above mentioned symptoms and much urine/turbid urine, thin thigh and knee joints and twinge of joint pain over the body. Yin-Deficit Diurnal-Heat (Eumheo-oyeol) pattern has symptoms like indigestion and epigastric discomfort, abdominal pain and vomiting in addition. Yin-Deficit Diurnal-Heat (Eumheo-oyeol) advanced pattern has symptoms like hematemesis as well.

이중 및 삼중 로이창호의 일사획득에 따른 사무소건물의 냉난방에너지 성능분석 (Heating & Cooling Energy Performance Analysis of an Office Building according to SHGC level of the Double & Triple Glazing with Low-e Coating)

  • 김효중;박재성;신우철;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.90-95
    • /
    • 2008
  • An SHGC(Solar Heat Gain Coefficient) is a determinant of total flux of solar radiation coming indoor and a critical factor in evaluating heating and cooling load. U-value represents heat loss while SHGC denominates heat gain. Recently, windows with high solar gain, mid solar gain or low solar gain are being produced with the development of Low-E coating technology. This study evaluated changes in energy consumption for heating and cooling according to changes in SHGC when using double-layered Low-E glass and triple layered Low-E glass in relation to double layered clear glass as base glass. An Office was chosen for the evaluation. For deriving optical properties of each window, WINDOW 5 by LBNL, an U.S. based company. and the results were analyzed to evaluate performance of heat and cooling energy on anannual basis using ESP-r, an energy interpretation program. Compared to the energy consumption of the double layered clear glass, the double layered Low-E glass with high solar gain consumed $69.5kWh/m^2,yr$, 9% more than the double layered clear glass in cooling energy. The one with mid solar gain consumed $63.1kWh/m^2,yr$, 1% less than the base glass while the one with low solar gain consumed $57.6kWh/m^2,yr$, 10% less than the base glass. When it comes to tripled layered glass, the ones with high solar showed 2% of increase respectively while the one with mid solar gain and low solar gain resulted 5% and 11% in decrease in energy consumption due to low acquisition of solar radiation. With respect to cooling energy. it was found that the lower the SHGC. the less energy consumption becomes.

  • PDF