• Title/Summary/Keyword: cleaning methods

Search Result 485, Processing Time 0.025 seconds

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes (상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구)

  • Seo, Jeewon;Lee, Gyusang;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.

Removal of small particles from silicon wafers using laser-induced shock waves (레이저 유기 충격파를 이용한 웨이퍼 표면 미소입자 제거)

  • 이종명;조성호
    • Laser Solutions
    • /
    • v.5 no.2
    • /
    • pp.9-15
    • /
    • 2002
  • Basic principles and unique characteristics of laser-induced shock cleaning have been described compared to a conventional laser cleaning method and the removal of small tungsten particles from silicon wafer surfaces was attempted using both methods. It was found that the conventional laser cleaning was not feasible to remove the tungsten particles whereas a successful removal of the particles was carried out by the laser-induced shock waves. From the quantitative analysis using a surface scanner, the average removal efficiency of the particles was more than 98% where smaller particles were slightly more difficult to remove probably due to the increased adhesion force with a decrease of the particle size. It was also seen that the gap distance between the laser focus and the wafer surface is an important processing parameter since the removal efficiency is strongly dependent on the gap distance.

  • PDF

Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

  • Rodiger, Matthias;Rinke, Sven;Ehret-Kleinau, Fenja;Pohlmeyer, Franziska;Lange, Katharina;Burgers, Ralf;Gersdorff, Nikolaus
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.233-240
    • /
    • 2014
  • PURPOSE. To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS. Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: $5.7^{\circ}$; customized-long, height: 6.79 mm, taper: $4.8^{\circ}$; customized-short, height: 4.31 mm, taper: $4.8^{\circ}$) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: $5.7^{\circ}$) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS. Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION. No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.

Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

  • Gehrke, Peter;Tabellion, Astrid;Fischer, Carsten
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.151-159
    • /
    • 2015
  • PURPOSE. To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS. A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non- quantitatively. RESULTS. All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION. The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented.

Study on Degradation Characteristics and Chemical Cleaning Methods of Plasticized PVC for Conservation of Plastic Artifact (연질 PVC 작품 보존을 위한 가소제 종류별 열화 특성 및 화학적 세척법 연구)

  • Lee, Na Ra;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.2
    • /
    • pp.159-168
    • /
    • 2019
  • Plasticizers, which are added to plastics, can cause exudation, which means that the plasticizer comes out from surface of the plastics. This causes the surface of plastic artworks to become sticky, and this allows dust and pollutants to become attached to the surface. Therefore, in this study, the degradation characteristics and chemical cleaning methods of each type of plasticizer are evaluated using PVC specimens. To evaluate the degradation characteristics and chemical cleaning methods, microscopic observation, chromaticity and weight measurement, and FT-IR spectroscopy were performed. The results showed that PVCs containing different plasticizers have different degradation patterns. Especially, the PVC containing TOTM showed discoloration and exudation. In the evaluation of the chemical cleaning methods, ethyl alcohol and KOH solution showed good effects, but their stability was not good. Surfactant was found to have a good cleaning effect and stability as a cleaner for exudated plasticizers.

Detergency of PET Film Having Various Surface Free Energy: Part I. Surface Tension of MAA Grafted PET Film (Polyethylene terephthalate 필름의 표면에너지 변화에 따른 세척성(제일보) Methacrylic acid 그라프트 PET 필름의 표면장력)

  • Chung Hae-Won;Kim Sung-Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.2 s.27
    • /
    • pp.217-223
    • /
    • 1988
  • This study is to examine the cleaningproof by dry cleaning runs and parts(shoulder, belly, butt) of garment leathers tanned chrome. This study is composed of three methods of test; color difference test, surface view by scanning electron micrographs, mechanical properties measurement by KES-FB system. The results obtained were as follows: 1. In stiffening of parts of sample, the belly is the best degree in smoothness, fullness, softness. But that of the butt have been found to be the worst degree and to be thick. 2. In fading of parts, the shoulder is an extreme case, but the belly is the best among three parts. 3. In dry cleaning runs, the view after 3 runs has been found to be the best result. 4. The stiffening after dry cleaning 1 run have been low grade, for the sample absorb much solvent of dry cleaning. And, the fading and the decoloration are to be worse after 5 runs. Because the leather surface is affected by dry cleaning runs.

  • PDF

Effects of Chestnut hulls Mordant on Oenothera Odorata Jacguin-Dyed Fabrics (달맞이꽃 염색시 율피매염 효과)

  • Seo, Hye-Young;Kim, Hye-Rim;Song, Wha-Soon
    • Fashion & Textile Research Journal
    • /
    • v.13 no.6
    • /
    • pp.983-989
    • /
    • 2011
  • This study aimed to identify mordant effects of Chestnut hulls. The color of post and pre-mordanted fabrics were measured in terms of H, V, C, $L^*$, $a^*$, $b^*$, and K/S values. In addition, color fastness and antimicrobial activity were evaluated. The pre-mordant concentration of Chestnut hulls for cotton, mercerized cotton and silk was optimized to 50% (o.w.f.) and 70% (o.w.f.), respectively. Post-mordant concentration of Chestnut hulls of mercerized cotton, silk and cotton was optimized to 50% (o.w.f.) and 90% (o.w.f.), respectively. The hue of fabrics was influenced by mordant methods, such as pre-mordant and post-mordant, slightly. Wet cleaning fastness of pre-mordanted cotton and mercerized cotton fabrics was higher than that of post-mordanted fabrics. The wet cleaning fastness of silk fabrics was not affected by the mordant method, and their fastness were proved to be excellent. The dry cleaning fastness of post-mordanted cotton fabrics was higher than that of pre-mordanted cotton fabrics. The dry cleaning fastness of mercerized cotton and silk was proved to be excellent regardless of mordant methods. The antimicrobial activity of Oenothera odorata jacquin dyed fabrics and Chestnut hulls mordanted fabrics was proved to 99.9%, and their excellent antimicrobial activity remained after wet and dry cleaning.

Natural Dyeing with Evening Primrose (달맞이꽃을 이용한 천연염색)

  • Seo, Hye-Young;Song, Wha-Soon;Kim, Hye-Rim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.2
    • /
    • pp.181-191
    • /
    • 2011
  • This study examines the effects of Evening primrose on colors, color fastness, and the antimicrobial activity of dyed fabrics. The results are as follows. The dyeing conditions of Evening primrose on cotton and mercerized cotton were optimized at $50^{\circ}C$, 60 minutes, and 200% (o.w.f.). In addition, Evening primrose dyeing on silk was determined at $90^{\circ}C$, 60 minutes and 200% (o.w.f.). The pre-mordant concentration of chemicals of cotton, mercerized cotton and silk was optimized at 1% (o.w.f.). The post-mordant concentration on mercerized cotton, silk and cotton was determined at 1% (o.w.f.) and 3% (o.w.f.), respectively. The mordant methods (such as pre-mordant and post-mordant) were slightly affected on the hue of dye-fabrics. Wet cleaning fastness of cotton was improved by post-mordant; otherwise, the wet cleaning fastness of mercerized cotton and silk was improved by a pre-mordant. The dry cleaning fastness of cotton and silk was excellent regardless of mordant methods. The dry cleaning fastness of mercerized cotton was improved by a post-mordant compared to a pre-mordant. The antimicrobial activity of Evening primrose-dyed fabrics was shown at 99.9%. The excellent antimicrobial activity of dyed fabrics remained after the mordant as well as wet and dry cleaning.

Comparison of Perceptions between Workers and Managers about the Working Environment Factors at Cleaning Companies Associated with the Electronics Industry (전자산업청소업체의 작업환경 요인들에 대한 근로자와 관리자와의 인식 비교)

  • Yu-Jeong An;Doo- Young Kim;Ki-Youn Kim;Daesung Lim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.427-438
    • /
    • 2023
  • Objectives: This study aims to create a safer working environment by examining the working environment of cleanroom cleaning workers through a survey and comparing the differences in perception between workers and managers. Methods: The survey was written based on the working environment and the safety and health management system. In order to improve the quality of the study, we visited the sites in person and conducted an in-depth interview. SPSS Statistics 26 (IBM, USA) was used to analyze the data. Results: Based on the survey, differences were found in chemical used, MSDS sharing methods, risk factors during cleaning work, work environment measurement results, special health examination items, places considered dangerous, and work. Conclusions: It is necessary that there be different work environments and risk factors for cleanroom cleaning workers at respective workplaces. As a result of the survey, there was found to be a difference in perception between workers and managers, and both workers and managers should try to reduce this difference.