DOI QR코드

DOI QR Code

Comparison of Perceptions between Workers and Managers about the Working Environment Factors at Cleaning Companies Associated with the Electronics Industry

전자산업청소업체의 작업환경 요인들에 대한 근로자와 관리자와의 인식 비교

  • Yu-Jeong An (Graduate Student, Department of Safety Engineering, Seoul National University of Science and Technology) ;
  • Doo- Young Kim (Graduate Student, Department of Safety Engineering, Seoul National University of Science and Technology) ;
  • Ki-Youn Kim (Graduate Student, Department of Safety Engineering, Seoul National University of Science and Technology) ;
  • Daesung Lim (Hansung Health and Safety Technology Co., Ltd.)
  • 안유정 (서울과학기술대학교 안전공학과대학원) ;
  • 김두영 (서울과학기술대학교 안전공학과대학원) ;
  • 김기연 (서울과학기술대학교 안전공학과대학원) ;
  • 임대성 (한성보건안전기술원)
  • Received : 2023.06.20
  • Accepted : 2023.10.20
  • Published : 2023.12.31

Abstract

Objectives: This study aims to create a safer working environment by examining the working environment of cleanroom cleaning workers through a survey and comparing the differences in perception between workers and managers. Methods: The survey was written based on the working environment and the safety and health management system. In order to improve the quality of the study, we visited the sites in person and conducted an in-depth interview. SPSS Statistics 26 (IBM, USA) was used to analyze the data. Results: Based on the survey, differences were found in chemical used, MSDS sharing methods, risk factors during cleaning work, work environment measurement results, special health examination items, places considered dangerous, and work. Conclusions: It is necessary that there be different work environments and risk factors for cleanroom cleaning workers at respective workplaces. As a result of the survey, there was found to be a difference in perception between workers and managers, and both workers and managers should try to reduce this difference.

Keywords

Acknowledgement

본 연구는 2022년 한국산업안전보건공단 산업 안전보건연구원 학술용역 지원 사업에 의해 수행되었음.

References

  1. Bae SJ, Jung MK, Ku DI, Jung SH, Kim MS. A case study on energy saving of air handling unit for clean room. The Society of Air-Conditioning And Refrigerating Engineers of Korea 2022;1252-1255
  2. Choi KM, Lee JE, Cho KY, Kim KS, Cho Sh. Clean room structure, air conditioning and contamination control systems in the semiconductor fabrication process. J Kor Soc Occup Environ Hyg 2015;25(2):202-210 https://doi.org/10.15269/JKSOEH.2015.25.2.202
  3. Kang SB. Work status in the cleaning service industry. Labor Review 2011;92-180
  4. Kil SB, Ryu SH, Park DU, Lee YK. Strategies for protecting waste collectors' health and safety. KSEH 2010;36(3):247-253
  5. Kim KC, Yoo KH, Lee GC, Kim Ys. Evaluation of annual energy consumption with an indoor water spray humidification system for semiconductor manufacturing clean rooms. The Society of Air-Conditioning And Refrigerating Engineers of Korea 2013:877-880
  6. Kim MH, Kim H, Paek D. The health impacts of semiconductor production: an epidemiologic review. International journal of occupational and environmental health 2014;20(2):95-114 https://doi.org/10.1179/2049396713Y.0000000050
  7. KOSHA. Study on the working environment and exposure characteristics of hazardous factors of workers in semiconductor manufacturing workplaces. 2012
  8. Lee GW. Understanding chemical substance management 57 - hazard and risk and safety and health activities in the semiconductor industry. Korean Industrial Hygiene Association 2016;26-29
  9. Lee SY & Lee JK. A case-based study on the architectural considerationsin the operational characteristics of industrial clean room. Korean Institute of Architectural Sustainable Environment and Building Systems 2013;7(1):48-57
  10. Lee YS. Cleanroom energy saving improvement case - cleanroom outer tank energy saving case.air cleaning technology. Korea Air Cleaning Association 2014;27(1):30-45
  11. Park DU. Review of hazardous agent level in wafer fabrication operation focusing on exposure to chemicals and radiation. Korean Industrial Hygiene Association 2016;26(1):1-10 https://doi.org/10.15269/JKSOEH.2016.26.1.1
  12. Jung WH & Song DS. A study on the analysis and improvement of annual energy consumption of outdoor air conditioner for semiconductor cleanroom. The Society of Air-Conditioning And Refrigerating Engineers of Korea 2022;202-205
  13. Yonhap News, "First Acknowledgment of Occupational Disease for Electronic Industry Janitors with Cancer: 'Society's Attention Needed'" https://m.yna.co.kr/view/AKR20220105083900004 2023,10.20
  14. Zhang Z & An SH. Improving the safety awareness of construction workers. Journal of the Korea Institute of Building Construction 14(5), 451-457.